Showing results: 166 - 180 of 195 items found.

  • SMART III RF Probe

    Finna Sensors

    Finna Sensors’ Smart III RF Moisture Probe is appropriate in those situations where NIR use on conveying systems/web applications or RF flat plate sensor use on board type products are not sufficient. Examples include tanks, bins, barrels, drums, Super Sacks™, silos, etc. These applications require a probe type moisture meter where the probe is inserted into, and is surrounded by product. Since the probe generates a 3 inch diameter radio frequency field around the length of the probe, a significant volume of product is measured. As the product is slowly removed from the silo, and refilled from the top, it passes by the RF Probe, thereby providing a constant real time moisture measurement. Typical applications would include starches, distillers and brewers grains, granulated chemicals or food ingredients, whole grains such as corn kernels, rice, soybeans, tree nut stockpiles, etc.

  • Confocal FLIM System

    DCS-120 - Becker & Hickl GmbH

    *FLIM Upgrade for Existing Conventional Microscope*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*One or Two BDL-SMN or BDS-SM ps Diode Lasers*Two Fully Confocal Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Wideband Version, Compatible with Tuneable Lasers*Electronic Pinhole Alignment*Z-Stack FLIM Acquisition with Zeiss Axio Observer Z1*Optional: Spatial Mosaic FLIM via Motorized Sample Stage

  • Multiphoton FLIM System

    DCS-120 MP - Becker & Hickl GmbH

    *Multiphoton FLIM Upgrade for Existing Conventional Microscope*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*Excitation by Ti:Sa Laser*Two Non-Descanned Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Electronic Pinhole Alignment*Z-Stack FLIM Acquisition with Zeiss Axio Observer Z1*Optional: Spatial Mosaic FLIM via Motorized Sample Stage*Laser Control via SPCM Software

  • Confocal FLIM for Macroscopic Objects

    DCS-120 Macro - Becker & Hickl GmbH

    *FLIM of Macroscopic Objects*Scan Field Up to 15 mm Diameter*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*One or Two BDL-SMN or BDS-SM ps Diode Lasers*Tuneable Excitation by Super-Continuum Laser with AOTF*Two Fully Parallel Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Wideband Version, Compatible with Tuneable Lasers*Electronic Pinhole Alignment*Optional: Spatial Mosaic FLIM via Motorized Sample Stage

  • Scientific Cameras

    Thorlabs, Inc.

    Thorlabs' Scientific-Grade Cameras are specifically designed for microscopy and other demanding applications. The Zelux™ CMOS cameras have small footprints and provide cost-effective solutions for general-purpose imaging applications. Kiralux® cameras have CMOS sensors with high quantum efficiency in a compact housing and are offered in monochrome, color, NIR-enhanced, and polarization-sensitive versions. Our polarization-sensitive CMOS camera is ideal for materials inspection, flaw detection, and other advanced techniques using polarization. The Quantalux® monochrome sCMOS cameras are fast frame rate imagers that combine high dynamic range with extremely low read noise for low-light applications. They are available in either a passively cooled compact housing or a hermetically sealed TE-cooled housing. We also offer scientific CCD cameras with a variety of features, including versions optimized for operation at UV, visible, or NIR wavelengths; fast-frame-rate cameras; TE-cooled or non-cooled housings; and versions with the sensor face plate removed. An intuitive software package, API and SDK for developers, and third-party software support provide options for custom system control and image acquisition.

  • Optical Spectrum Analyzer Module Specification

    CA92001B - UC Instruments, Corp.

    UCINSTRUMENTS CA92001B C band optical spectrum analyzer module is a spectral engine for Process Analytical Technology applications. The OSA module acts as a stand-alone spectral engine, imaging and measuring a wide range of vapors, liquids and solids through transmission and diffuse reflection in a rapid non-destructive process. Leveraging our proprietary Micro-Optic technology, UC INSTRUMENTS’ C band OSA module features the following characteristics: (1) compact; (2) light-weight; (3) low power consumption; and (4) wide wavelength coverage. These characteristics of UC INSTRUMENTS’ compact OSA engines are suitable for a variety of handheld, portable or bench-top OSA/spectrometer applications. Equipped with a state-of-the-art internal wavelength reference, the OSA module is capable of precisely measuring optical spectrum. Because it does not require an expensive InGaAs detector array, the compact OSA module is a cost-effective alternative to other grating-based OSA/spectrometer engines. The OSA communicates with a PC or an instrument motherboard via an USB interface. UCINSTRUMENTS’ OSA module platform can be installed or co-packaged into existing NIR OSA/spectrometers as a cost-efficient alternative to other scanning optical engines.

  • Testing for Si Solar Cells Using High Performance CCD

    EL Imaging Tester - OAI

    EL Testing for Si Solar Cells using High Performance CCD. The determination of luminescence (photo emissions) in solar cells is an important characterization tool. Typical solar cells often have defects which limit the efficiency or lifetime of a cell. Many of these defects are visualized with Luminescence Imaging. By using this technique, the manufacturing process can be optimized to produce better cells. Luminescence Imaging takes advantage of the radiative inter-band recombination of excited charge carriers in solar cells. The emitted photons can be captured with a sensitive CCD camera to obtain an image of the distribution of the radiative recombination in the cell. This distribution is determined by the local excitation level, allowing the detection of electrical losses, thus mapping the diffusion length of minority carriers as the emitted light is low intensity and in the near infra-red range, the CCD camera has a high sensitivity wavelength from 900 to 1100 nm with little thermal noise. This CCD camera provides excellent resolution of 1024 x 1024 pixels with a large 1μm pixel size, multi-megahertz readout speed, and robust USB 2.0 connectivity. The EL CCD Camera is the ultimate high-performance CCD camera for electroluminescence and photoluminescence imaging for Photovoltaic (PV) Cells and Modules. This camera combines low noise electronics and optimal sensitivity in NIR.

  • Photodiodes

    Opto Diode

    Opto Diode manufactures high quality standard and custom photodiodes. Our wide range of standard device feature low dark current and low capacitance. The silicon detectors are ideal for general purpose applications, laser monitoring, position sensing, measuring photons, electrons, or X-rays, or for detecting sun and rain applications. The devices operate from the deep UV to the near-infrared wavelengths.

  • Pyroelectric Infrared Sensor

    Fuji Ceramics Corporation

    Pyroelectric infrared sensor is a sensor to catch the faint infrared rays generated from the object. This is for the sensing objects, does not exert any impacts. And, it will deliver the information about the presences and situations of the sensing objects. Pyroelectric sensor, to the far infrared rays from near-infrared rays, is a general-purpose sensor with high sensitivity with a wide detection range of wavelengths.

  • SiTek Standard PSD

    1L20_CP3 - SiTek Electro Optics AB

    The SiTek Standard PSD (Position Sensing Detector) has high resolution, fast response and outstanding linearity. It is used in a wide variety of applications, most of them utilizing light sources in the visible or near-infrared part of the spectrum. The spectral range covers the region 400 - 1100 nm. Thanks to SiTek's proprietary AR-coating, optimized around 860 nm, a reflection loss of only 2% is achieved around the responsivity peak. Most of the detectors have a cover window to avoid handling damages.

  • SLD Light Source

    FiberLabs Inc.

    The SLD light source is a light source to emit low-coherence light with a broad spectrum like LED and high brightness like LD. Light emitted from a narrow active layer like LD effectively couple to the fiber. SLD light source can be used for optical measurements and sensors, including fiber optic gyroscopes and OCT. FiberLabs provides fiber-output SLD light sources in different wavelength bands from visible to near-infrared light. Our lineup includes bench-top types convenient for experiments and easy-to-integrate module types.

  • Spectral Sensing

    ams AG

    The ams multi-spectral sensing family includes a broad array of spectral sensing devices providing between 6 and 18 channels in the visible and near-infrared spectrum. All products feature CMOS interference filters and benefit from innovative factory calibration to deliver precise spectral characteristics over their lifetime. Most include direct LED drivers to synchronize and control light sources for efficient digital shutter operations.

  • Field-installation Type MLSS Meter (Four-Wire Transmission)

    HU-200SS - HORIBA, Ltd.

    HU-200SS connects immersion type MLSS sensor (SS-90) and measures MLSS in activated sludge. A wide range (0-2000mg/L)of SS contents can be measured with excellent reproducibility using the near-infrared radiation transmission method. Any of the calibration curves of MLSS, Clay (inorganic mud) and Kaolin may be used as standard substances of SS. If "MLSS" is selected for an activated sludge treatment tank, "Clay" for the precipitation treatment of construction sludge, or "Kaolin" for white mud, a concentration can be obtained closer to an analyzed value.

  • Near-infrared Spectroscopy Evaluation Module

    DLP® NIRscan™ Nano - Texas Instruments

    The DLP NIRscan Nano is a compact battery-operated evaluation module (EVM) for portable near-infrared spectroscopy solutions. Featuring the DLP2010NIR digital micromirror device (DMD), the NIRscan Nano supports Bluetooth low energy to enable mobile lab measurements for hand-held spectrometers.

  • Single Photon Detector System For Near-Infrared (1.3 - 1.6 Um Wavelength) Waves With Liquid Helium (LHe) Cryostat

    Insight Product Company

    Insight Product Company is proud to offer Single Photon Detector System for Near-Infrared (1.3-1.6 um wavelength) with Liquid Helium (LHe) Cryostat. Insight Product Co. offers superconducting single photon detectors and ultra-low noise registration systems for the near infrared range. All systems operate in continuous mode, no gating required.