Filter Results By:

Products

Applications

Manufacturers

Matrices

Grid array with switches at each circuit crossing connecting multiple inputs to multiple outputs.

See Also: Matrix, Switch Matrix


Showing results: 796 - 806 of 806 items found.

  • 2-Slot USB/LXI Modular Chassis

    60-104-001 - Pickering Interfaces Ltd.

    This 2-slot USB/LXI modular chassis offers a small lightweight form factor, making it ideal for portable, benchtop, and space restrictive applications. The chassis is designed for desk or rack mounting and features remote control via USB or LXI Ethernet. Remote control over a network enables the switching function of a test system to be located as close as possible to the target equipment. The 60-104 chassis supports one or two 3U PXI modules and accepts Pickering's PXI products, it is the perfect platform to construct small scale applications. Possible systems include switching matrices up to 1104 crosspoints, 396 channel multiplexer or up to 36 channels of programmable resistor/sensor emulation.

  • PXIe-2541, 300 MHz, 8x12 PXI RF Matrix Switch Module

    780587-41 - NI

    PXIe, 300 MHz, 8x12 PXI RF Matrix Switch Module—The PXIe‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXIe‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXIe‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.

  • PXI-2541, 300 MHz, 8x12 PXI RF Matrix Switch Module

    778572-41 - NI

    300 MHz, 8x12 PXI RF Matrix Switch Module—The PXI‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXI‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.

  • High Performance Liquid Chromatograph Triple Quadrupole Mass Spectrometer

    LCMS-8060 - Shimadzu Corp.

    The LCMS-8060 features an optimized ion guide and new technologies incorporated in the ion transport optical system. As a result, the ion sampling efficiency and ion focusing capability are significantly increased, to achieve improved sensitivity, approx. 3 times better than that of the LCMS-8050. Inheriting the high-speed performance of the LCMS-8050, this flagship model in the UFMS series features both the world's highest level of sensitivity and the world's highest throughput. It is capable of detecting ultra trace components in complex matrices, which have been difficult to detect to date, both quickly and with high sensitivity. This will contribute to further improvements in data quality in all types of trace quantitative analysis applications, such as for biological samples, which requires the highest level of sensitivity.

  • PXI Carrier Module For SwitchBlock

    NI

    The PXI Carrier Module for SwitchBlock can hold up to six Matrix Modules for SwitchBlock while occupying four PXI slots. By connecting multiple SwitchBlock relay cards through the carrier's integrated analog bus, you can easily create large matrices with more than 2,000 crosspoints in four PXI slots and more than 8,000 crosspoints in a single PXI chassis. Each Matrix Module for SwitchBlock comes in an A-type version, which serves as the first matrix building block and offers row and column access through the front connector, and a B-type version, which serves as an expansion module and only provides column access through the front connector. Typically, SwitchBlock systems contain one A-type module and numerous B-type modules.

  • PXI Single 24x8 Matrix, 2 Pole Switching

    40-521-022 - Pickering Interfaces Ltd.

    Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.

  • PXI Dual 16x8 Matrix, 2 Pole Switching

    40-532-022 - Pickering Interfaces Ltd.

    This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.

  • PXI Single 32x8 Matrix, 2 Pole Switching

    40-531-022 - Pickering Interfaces Ltd.

    Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.

  • Energy Dispersive X-ray Fluorescence Analyzer

    X-5000 - HORIBA, Ltd.

    HORIBA continues it's innovation in the petroleum market by proudly teaming with Olympus Innov-X to promote the X-5000 Mobile XRF Analyzer. The X-5000 is a rugged, fully integrated closed beam portable EDXRF system that offers the power and performance of a traditional benchtop XRF, but is designed for transportable operation. Using a Silicone Drift Detector, low PPM detection limits can be achieved for many elements in a variety of sample types and matrices. Applications include fuels, additives, and wear metal oils to crude oils, water, coke, and coal allow this easy to use analyzer to be a fast, flexible solution to traditional testing methods.Detectable elements to concentrations of 100% are: Aluminum, Antimony, Barium, Cadmium, Calcium, Chlorine, Chromium, Copper, Iron, Manganese, Molybdenum, Nickel, Phosphorous, Potassium, Silicon, Silver, Sulfur, Tin, Titanium, Vanadium, and Zinc.

  • GENASYS High Density Matrix Switch Card, 104 X 8 X 8

    GX6188 Series - Marvin Test Solutions, Inc.

    The GX6188 is a 6U PXI, high density matrix, GENASYS architecture switching card. The card provides the user with the ability to connect and interface resources to multiple UUT connections. The board consists of two matrices - a 104x8 and a 8x8 matrix. The GX6188 can connect to 104 UUT switching points, eight external resources and an eight channel global bus via front panel connectors. Multiple GX6188 cards can be connected using the global bus. Like other GENASYS switch cards, the GX6188 features an integral, 3-dimensional switching architecture which provides the flexibility to connect test system resources to multiple UUT connections as well as supporting an expansion bus connection without sacrificing I/O matrix connections when building multiple switch card configurations.

  • High Voltage Switching Systems

    HXV Series - Cytec Corp.

    HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.

Get Help