Magnetic
attraction; of opposite polarity objects, magnets to ferrous materials and themselves.
See Also: Force, Compression, Crimp Force, Pull Force, Pull off Force, Push Pull Force, Peeling, Tension, Gravity, Electrical, Magnetic Test, Magnetic Field, Magnetic Head, Magnetic Susceptibility, Magnetic Flux, Magnetic Stripe, Magnetic Permeability, H-field, Core Loss
-
Product
Magnetic Field and Permeability Measurement
MAGNETOSCOP® 1.070
-
Foerster Instruments, Incorporated
The MAGNETOSCOP 1.070 is a portable magnetometer system with microprocessor and probes for measuring the magnetic flux density as an absolute or differential value (gradient). It has a USB port for simple data transfer and an SD card for saving measurement data and parameters. The measuring system also facilitates the recognition and saving of peak values and the adjustment of thresholds for limit values. The unit can be used for series and individual measurements. The data can be easily analyzed and documented with the PC software included in the scope of delivery. The MAGNETOSCOP 1.070 thus facilitates the portable and fast measurement of the relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys as well as the localization of ferrite enclosures. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.
-
Product
Magnetic Field Visualization
cmos-magview
-
The devices of the cmos-magview family are high-resolution and precise measuring and visualization systems for magnetic materials, assemblies and surfaces. Pole distances or other geometric information can be measured down to the µm range.
-
Product
Digital Teslameters/Gaussmeters
-
S Digital Teslameters offer accurate, high resolution measurement of magnetic flux densities, withdirect digital readout in tesla or gauss, and serialcommunications by fiber optics or RS-232C for system applications.The instruments are light and compact, and the probes are easy to use. The DTM-151 has been engineered to withstandthe severe electrical interference produced by high voltage discharge.
-
Product
Ground Grid Tester
GGT Series
-
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.
-
Product
Logger version 2-D electro-magnetic current meter
INFINITY-EM AEM-USB
-
Infinity EM is an autonomously deployable EM (electro-magnetic) current meter with a data logger. Due to the principle, the instrument provides high accurate 2-D current measurements in even low scatter fields, where ADVs (Acoustic Doppler Velocimeter) has difficulties. The measurement range is wide from 0 to ± 500 cm s-1. The instrument design is compact (1.0kg in air). Infinity EM allows for current velocity measurements virtually anywhere.
-
Product
Cryocoolers
-
Cryogenic uses various cryocoolers with cooling powers to suit different cryogen free magnet systems and applications. The Gifford-McMahon cycle cryocooler has the advantage of greater thermodynamic efficiency. The pulse-tube cryocooler is vibrationally quieter, has a longer service interval and cools faster from room temperature.
-
Product
Primary Current Injection
PCI-600
-
The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers.
-
Product
Magnetic Field Sensor
-
Vernier Software & Technology, LLC
The Magnetic Field Sensor can be used to study the field around permanent magnets, coils, and electrical devices. It features a rotating sensor tip to measure both transverse and longitudinal magnetic fields.
-
Product
TMR Magnetic Pattern Recognition Sensors
-
MultiDimension Technology Co.,Ltd.
A type of 6 channels magnetic pattern recognition sensor built-in the signal conditioner and SPI interface Consists of TMR magneto-resistance sensor, high-quality magnet, high-strength plastic base and durable non-magnetic stainless steel cover; Are used for detecting the paper bills, bank notes and security documents with magnetic anti-counterfeiting consists.
-
Product
Magnet Testing
m-cat
-
m-cat is a magnetic field mapper for magnetrons which measures the magnetic stray field data of magnetrons on all three spatial axes and also calculates geometric data. This allows sputtering processes to be monitored and optimized, since the setting or status of the magnetron is critical to the subsequent outcome of the coating process.
-
Product
CU-2 Digital Controller
SX
-
Power consumption has been reduced by a new controlled charging method using a three-phase power supply, and high-speed charging has become possible. It is often used for large magnetizers that consume a lot of power and have a long charging time.
-
Product
Magnet Wheels Pulse Generators
199SM / 198EM Magnet Wheels
-
Magnet wheels work with Electro-Sensors Hall Effect shaft speed sensors providing 120 alternating magnetic poles around the circumference of the 3.75" diameter. The 199SM models mount around shafts up to 3" in diameter and are secured with set screws (provided). The 198EM mounts on the end of a shaft with a 10-32 UNF screw (provided - requires center drilling and tapping the shaft).• Use with 906, 906B, 1101 and other Hall Effect, non-metallic-end-capped shaft speed sensors (consult factory)
-
Product
Fluxmeter
-
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
Product
Fluxmeters
-
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.
-
Product
250 A Molded Case Circuit Breaker Tester
MCCB-250
-
The Vanguard MCCB-250 is a programmable, high-current source designed specifically for testing molded-case circuit breakers, thermal magnetic and solid-state overload motor-protection relays.
-
Product
Speed Switch
SCP1000/SCP2000
-
Features• Internal sensor• Over-or under-speed config., 1-990 rpm• 1 DPDT relay output (SCP1000), 2 SPDT relay outputs (SCP2000)• Built-in start delay• Dial-in calibration does not require power• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• Works with Electro-Sensors magnetic pulser discs / wraps• Explosion proof housing• UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)
-
Product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ZCT-110
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for low leakage current measurements of less than 1mA.*Suitable for low current measurements of terminal feeder.*High sensitivity and least affection from external magnetic field.
-
Product
Zero Gauss Chamber, Zero Field Chamber
ZG-2
-
The WUNTRONIC Zero-Gauss-Chamber insolate the environment magnet fields. The Zero field camber is very usefull for zero adjustments of Teslameters / Gauss meters.
-
Product
Absolute Magnetic Kit Encoder
MAE3
-
The MAE3 is an absolute magnetic kit encoder that provides shaft position information over 360 of rotation with no stops or gaps. This magnetic encoder is designed to easily mount to, and dismount from, an existing shaft to provide digital feedback information. The MAE3 is available with an analog or a pulse width modulated (PWM) digital output.
-
Product
Coating Thickness Gauge for Ferrous and Non-Ferrous Materials
CM8856
-
* It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTM and BS. It can be used both in the laboratory and in harsh field conditions.* The F probes measure the thickness of non-magnetic materials (e.g. paint,plastic, porcelain enamel, copper, zinc,aluminum , chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness ofgalvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminum tile, somealloy tile, paper etc.The N probes measure the thickness of non - magnetic coatings on non-magnetic metals .It is used on anodizing, varnish, paint, enamel,plastic coatings, powder, etc. appliedto aluminum, brass, non-magnetic stainless steel, etc.* Automatic substrate recognition.* Manual or automatic shut down.* Two measurement mode: Single andContinuous* Wide measuring range and highresolution.* Metric/Imperial conversion.* Digital backlit display gives exactreading with no guessing or errors.* Can communicate with PC computerfor statistics and printing by theoptional cable.* Can store 99 groups of measurements.* Statistics is available.2.SPECIFICATIONSDisplay: 4 digits LCD, backlitRange: 0~1250 μm/0~50mil(other ranges can be specified )Min.radius workpiece: F: Convex 1.5mm/Concave 25mmN: Convex 3mm/ Concave 50mmMin. measuring area: 6mmMin.Sample thickness : 0.3mmResolution: 0.1 μm (0~99.9μm);1 μm (over 100μm)Accuracy: ±1~3%n or 2.5 μm or 0.1mil(Whichever is the greater)Bttery Indicator: Low batter indicator.PC interface: with RS-232C interfacePower supply: 2x1.5 AAA(UM-4) batteryOperating condition: Temp. 0~50℃ .Humidity <95% .Size: 126x65x35 mm; 5.0x2.6x1.6 inchWeight: about 81g(not including batteries)Standard accessories:Carrying case ...................1 pc.Operation manual ............ 1 pc.F probe in built .................1 pc.NF probe in built...............1 pc.Calibration foils ..............1set.Substrate (Iron) ................1 pc.Substrate (Aluminium)......1 pc.Optional accessories: RS-232C cable & software:1.USB adaptor for RS-232C2.Bluetooth interface
-
Product
Sensors
Magneto-Optical Sensors (MO Sensors)
-
The highly sensitive magneto-optical (MO) sensors form the basis for visualizing magnetic fields in production and research.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Split type Pulse Current Sensor
CTF-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Suitable for the operation and cable continuity check of the equipment by pulse current detection method. Wide AC current range from 0.1mA to 8A. Ultra compact and light weight. High sensitivity and least affection from external magnetic field.
-
Product
Single Channel Signal Conditioner
SAM-3
-
Macintyre Electronic Design Associa
The SAM-3 is a portable single channel signal conditioneer specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from eitherits internal batteries or the power line. It incorporates two sets of power line rejection fileters, switch selectable fro 50 to 60 Hz and the corresponding first four harmonics.
-
Product
192 X 4 / Dual 96 X 4, cPCI High Density Matrix Module
DP-cPCI-4149
-
Matrix switches are the most versatile type of switching system. Any input can be connected to any output, singly or in combination. A matrix switch simplifies the signal routing in an overall system, through reduced internal connection path.DP-cPCI-4149 offers ultra high density matrix in a single slot 6U sized cPCI module with flexibility to configure in the following ways:192 x 4 (Single- wire).Dual 96 x 4 (Single -wire).96 x 4 (Two-wire)DP-cPCI-4149 uses magnetically screened reed relays.
-
Product
T-Coil Magnetometer
-
The TEM Consulting T-Coil Magnetometer provides an effective solution for measurement to ANSI C63.19 Clause 6 and other magnetic field readings. The system uses a high precision, anti-aliasing digital acquisition PCI bus board for convenient and accurate measurement.
-
Product
Automotive Fuse Current Probe
FUSE PEEKER
-
Automotive Diagnostics and Publishing
Automotive Fuse Peeker Current Probe for Testing Injectors, Coils, Solenoids and most components. The FUSE PEEKER Automotive Fuse Current Probe works with your own scope, the Auto Scope 1 or any other type of oscilloscope. It uses magnetic sensor technology, which is accurate and safe for your tool. It can detect small amounts of current as small as 5 milli-amps.
-
Product
Speed Pick-up
SU63
-
The Validyne SU63 is an AC inductive speed pick-up used for RPM measurement on high-speed rotating equipment. The SU63 is a tightly-wound coil with a laminated core that can be conveniently mounted on rotating equipment so that the magnetic field of a magnetized nut or part passes through the coil windings. The moving magnetic field produces a voltage within the coil proportional to its rate of change and the strength of the permanent magnetized part. The frequency of this inductive voltage spike is fed into an oscilloscope or counter to determine RPM.
-
Product
Handheld 1-D electro-magnetic current meter for rivers
AEM1-DA
-
AEM1-DA is a 1-D electro-magnetic (EM) current meter for the flow measurements in rivers, streams and various waterways. The measurement range is 0 to 5m s-1. The EM sensor can accurately measure water speeds at a shallow depth of 3cm. The display unit has a 2MB flash memory so that the data are saved with calendar information (up to 255 station data). In comparison with conventional propeller-type current meter, AEM1-DA is robust and extremely easy to be operated and maintained.
-
Product
Current Probe
-
Vernier Software & Technology, LLC
Simplify your experimental setup with the Go Direct Current Probe. It connects wirelessly via Bluetooth® or wired via USB to your device. The wireless connection eliminates additional cables that can clutter the lab bench. Capture small currents like those produced by a magnet falling through a coil.