Showing results: 166 - 180 of 289 items found.
-
SC6540 -
Associated Research
Our patented SC6540 modular scanning matrix pioneered the largest productivity improvement in the electrical safety compliance industry in years. With up to 16 independent high voltage or high current channels in a convenient 2U design, the SC6540 can be customized in 10 different configurations for multi-point Hipot, Ground Bond, Insulation Resistance and Leakage Current testing.
-
STP-01RAN/STP-01RFN/STP-01RFB -
HK Film Capacitor Ltd
This series of capacitors is Plastic Enclosure, Dry construction design and doesn't have leakage problem when compared with traditional Metal Enclosure Oil impregnated capacitors.Handle Medium Frequency range, high surge current, RMS current and surge voltage with temperature up to +105CCapacitance : 0.1uF - 15uF ( can be customized )Voltage range : 1,200Vdc to 17,000Vdc / 350Vrms to 6,900VrmsRMS Current - Irms : up to 100Armspeak to peak pulse current - Ipp : up to 5,900AppTemperature ranges : +85C / +105C
-
M-740 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High sensitive for low range leakage current*Suitable for measurement of 4-20mA DC controlled circuit*DC mV analog signal output*Lowest influence from Magnetization and Terrestrial magnetism*Wide measuring ranges - up to DC 1000mA and AC10A
-
LXinstruments GmbH
The system is used to characterize the leakage currents of capacitor packages. LXinstruments implemented a project-specific PCBA for the required HV switching. The measurement technology consists of Keithley source meters and USB based devices. The DUT adaptation with safety technology was realized in cooperation with ATX.
-
2672C -
Shenzhen Chuangxin Instruments Co., Ltd.
*High voltage, large current, high accuracy.*Leakage current, testing time, continuous arbitrarily, well-adapted.*Synchronized display measuring value( time, voltage and current).*Can choose manual or remote control test*High voltage breakdown protection, sound and light alarm, safe and reliable *Easy operation, suitable for use in production line*DC output can test small capacitance, high-voltage silicon stack, reverse voltage of transistors
-
M-700 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High sensitive for low range leakage current.*Suitable for measurement of 4-20mA DC controlled circuit.*DC mV analog signal output.*Lowest influence from Magnetization and Terrestrial magnetism.*Wide measuring ranges up to DC 1000mA and AC 10A.
-
doblePRIME IDD -
Doble Engineering
The doblePRIME IDD Bushing Monitor detects deterioration in bushings, finding abnormalities in the insulation and issuing actionable alerts.The doblePRIME IDD Bushing Monitor provides leakage current and phase analysis for up to 12 bushings, measuring parameters for each bushing individually and together.
-
AMIC-5005 -
Amperis sl
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current ;Function with digital filter
-
Sentinel III -
Chroma Systems Solutions, Inc.
The Sentinel III System provides complete Electrical Safety Testing to IEC60601-1 and IEC 60601-2-49 (Multifunctional Patient Monitoring Equipment) in a fully automated fashion. The Sentinel III saves time by scanning patient connections for leakage current without powering down the device.
-
PAT-815 -
Sonel S.A.
TECHNICAL SPECIFICATIONFILESPAT-815 digital meter is used to measure the parameters of electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power, automatic measurement of all RCD parameters.
-
Yokogawa Test & Measurement Corp.
With our 16 models of different clamp-on testers, Yokogawa provides the right tool for the job. Our CL Series consists of AC, AC/DC, and leakage current clamps with various ranges and dimensions. The multiple options include RMS, Mean, Temperature, frequency, and recorder output.
-
Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
KVZG -
KV Hipot Power Test Equipment Co.,Ltd
DC Hipot Tester is applied to measure output voltage and leakage current for zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipment.
-
Weshine Electric Manufacturing Co., Ltd
1. This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.
-
Sentris -
OptoTherm, Inc.
Due to the continued decrease in integrated circuit feature size and supply voltages, detecting and locating the miniscule amount of heat generated by failure sites has become increasingly difficult. Sentris pinpoints low-level infrared thermal emissions from IC faults such as short circuits and leakage current.