Showing results: 211 - 225 of 1447 items found.
-
LDM-100 -
Standard Instruments Co., LTD.
Featured is a laser distance meter that is designed with precision to ensure accurate measurements. It allows indirect measurements with the Pythagoras technology. Brief illumination display or detailed multi-line display are available for your option.
-
Leuze electronic GmbH + Co. KG
Thanks to the configurable protective and warning fields, safety laser scanners can be used versatilely for danger zone and access guarding. Their compact design makes them ideal both for stationary and for mobile applications. Our RSL 400 safety laser scanners are characterized by their performance, robustness and easy handling. Thanks to its high operating range of 8.25 m and a scanning angle of 270°, it can monitor even large areas. The series also includes models for integration via PROFIsafe/PROFINET interface and models with data output for the navigation of automated guided vehicles.
-
MTI Instruments
Ultimate laser displacement sensor for measuring height, thickness, displacement, vibration, and more, with a sensor frame rate of 40k Samples/sec. and linearity of 0.03% FSO (Full Scale Output) accuracy and repeatability are assured
-
HT Italia Srl
Those Laser distance meters are the evolution of linear measurement with possibility of carrying out precision measurements, geometric calculations and transferring data onto your smartphone or tablet through the relevant App, available in the store.
-
OLS4100 -
Olympus Corp.
The LEXT OLS4100 is a Laser Scanning Microscope to perform non-contact 3D observations and measurements of surface features at 10 nanometer resolutions. It also features a fast image acquisition and a high-resolution image over a wider area.
-
Santa Barbara Infrared, Inc.
Santa Barbara Infrared, Inc. offers an extensive family of test systems and components that test and characterize the performance of laser range finders, designators, illuminators and spot trackers. In this section, detailed information is provided for the following:
-
Ametek Process Instruments
Tunable diode laser absorption spectroscopy (TDLAS) is a fast, accurate, non-contact gas analysis technique that responds quickly to changing analyte concentrations. It is a proven technology free of interferences from other sample stream components.
-
KM 973 -
Kusam Electrical Industries Limited
• Measuring Range : 0.05 to 40M (KM 973) , 0.05 to 70M (KM 975), 0.05 to 100M (KM 976) • Measuring Accuracy : ± 2 mm• Display Accuracy : 1 mm• Laser Classification : Class 2M II• Laser Type : 620-690nm, <1mW• Protection against splashes and dust : IP 54• Temperature range for Operation : 0°C to +40°C• Temperature range for Storage : -20°C to +70°C• Laser Switch-OFF Automatically : After 30 Seconds• Instrument Switch-OFF Automatically : After 3 Minutes• Area, Volume Measuring.• Indirect (Pythagoras) Measurement.• Plus-Minus Method.• Continuous Measurement.• Minimum / Maximum Measurement.• Display illumination.• Show beep.• Battery Life : 5000 to 8000 Measurements• Battery Selection : Lr6 (AA) 2 x 1.5V• Dimensions : 121(L) x 56(W) x 28(H) mm• Weight : 150g
-
Sparklike Oy
Sparklike Laser Integrated™ is an automated insulating gas measurement station, which is integrated in the IG production line. In addition to measuring the gas concentration of IGUs, it helps with monitoring possible over fill and optimizes the use of butyl.
-
Panasonic Industrial Devices Sales Company of America
When your application calls for the precision measurement of dimensions such as thickness, diameter, and height, Panasonic has the solution. Panasonic high-quality Laser Displacement, Inductive Displacement and Collimated Beam Sensors provide high-speed and accurate measurement solutions.
-
Carl Zeiss AG
A confocal laser scanning microscope scans a sample sequentially point by point, or multiple points at once. The pixel information is assembled into an image. As a result you acquire optical sections with high contrast and high resolution in x, y and z .
-
Jinan Testing Equipment IE Corporation
Model LE-05 and LE-15 extensometers measure strain optically, without contacting the specimen, using laser diode technology. The extensometers are self-contained and portable. They may be interfaced with a variety of testing machines and data acquisition systems using the ±10V analog output or bi-directional RS-232 serial port. Operation may be local or remote. A digital display is included. The scanning beam is always perpendicular to the specimen, unlike most laser extensometers. This eliminates errors when viewing through windows in chambers. It also minimizes sensitivity to the distance between the extensometer and the sample. Because the unit measures reflected light, no receiver is required behind the sample.
-
LCD-4400 -
Korima, Inc.
The LCD4400 offers an economical, precision instruments designed to repair short, remove excess material (ITO, Cr, Al…) on panel before or after assembly. Featuring lightweight, state of the art technology, the LCD4400 focuses a Nd:YAG laser directly through microscope objective.
-
SAT-3E -
Shaanxi Aitelong Technology Co., Ltd
SAT-3E optical laser source fits to optical power meter to measure fiber loss and evaluate transmission performance. They are indispensable tool for optical network installation, trouble shooting, maintenance and widely used in LAN, WAN, CATV, remote optical network, etc.
-
LGR-ICOS Series -
ABB Ltd.
LGR-ICOS laser process analyzers accurately measure gas concentrations with extraordinarily high sensitivity, fast response and over a wide dynamic range in both simple and complex mixtures. They are ideal for contaminant monitoring in HyCO (syngas), fuel gas, petrochemicals, and semiconductor fabrication facilities.