  • (40×70×12mm) Full Function Single Channel Small Form Factor Booster EDFA Module

    SBA4100-FM01 - Hangzhou Huatai Optic Tech. Co., Ltd.

    SBA4100-FM01 is a full-function single channel booster EDFA module with digital control electronics, adopts subminiature 40×70×12mm compact package. The module uses high performance non-cooling pump laser, combined with artistic package and best optic performance, creating the best flexible and variable low-cost amplifier in the market. This module is suitable for multiple network application, especially the application that requires 40GB/S transmission speed.

  • FLIM Upgrade Kits for LSMs

    Becker & Hickl GmbH

    As technology leader in equipment and techniques for single photon counting, Becker & Hickl offers a wide range of high-grade Fluorescence Lifetime Imaging (FLIM) systems for laser scanning microscopes since 1998. Our techniques have found broad application within the scope of Life Sciences, Clinical FLIM, Diffuse Optical Tomography (DOT), Fluorescence Correlation (FCS, FCCS), Förster Resonance Energy Transfer (FRET) and more.

  • Metal Cored PCB

    Teledyne Labtech

    Teledyne Labtech is at the forefront of complex metal-cored PCB design and manufacture. The PCB use a thin metal core <2 mm, which acts as isolation between the RF/Microwave circuit and the Analogue/Digital circuitry and creates an excellent thermal path.The major advantages are reduced size and no need for complex microwave feed-thru's. The ability to laser cut pockets allows the designer engineer to mount the high power MMIC directly on to the metal core.

  • Wide-Field FLIM System

    LINCam FLIM - Becker & Hickl GmbH

    *Easy to Use Like an Ordinal Megapixel CCD Camera*Spatial Resolution ~ 1024 x 1024 Pixels*Temporal Resolution (IRF Width) 50 ps FWHM*Single-Photon Sensitivity*Saturated Count Rate Up to 5 MHz*Excitation by bh BDS-SM Family ps Diode Laser*Works with All Commonly Used MicroscopesI*llumination via Single-Mode Fiber*Lens System for Image Transfer Into Camera

  • Terahertz Systems

    TOPTICA Photonics Inc

    Optoelectronic Terahertz-Generation. TOPTICA provides complete systems and components for both time-domain and frequency-domain terahertz generation. For time-domain applications, the TeraFlash sets new standards in terms of dynamic range, bandwidth and measurement speed. Combining TOPTICA's FemtoFiber smart laser technology with state-of-the-art InGaAs antennas, the system achieves a peak dynamic range of more than 90 dB and a bandwidth greater than 5 THz.

  • Positioner LD

    DVTest Inc.

    The DVTEST LD Positioner is a two-axis elevation over azimuth positioner, for precise angular positioning with full spherical coverage. The LD Positioner is designed for the precise characterization of lightweight devices. The positioner is constructed from a low-permittivity polymer, for minimal reflections and multipath. For increased accuracy, the motor is outfitted with an absolute encoder, and laser guided calibration. A USB controller is included, with the positioner operated via Python or Matlab software libraries.

  • Molecular Spectroscopy

    Agilent Technologies

    Agilent’s best-in-class portfolio of molecular spectroscopy instruments have grown in breadth as well as capabilities. With leading innovations like the Cary 3500 UV-Vis and laser direct infrared (LDIR) chemical imaging, through to the 4300 handheld FTIR and our proprietary spatially offset and transmission Raman technologies, our spectroscopy systems are more qualified than ever to equip you with the right solution for your specific challenge.

  • Extreme Environment Sensors

    Kaman Fuzing & Precision Products

    For high pressure, low temperature, and high temperature applications* For applications requiring high accuracy, high reliability, and structural integrity.* Operating temperatures from -320°F to +1000°F (+1200°F short term).* Displacement systems withstand pressures up to 3500 or 5000 psi.* Dual-coil sensor design effectively minimizes radiation effects.* Hermetically sealed and laser welded.* Unaffected by environmental contaminants.

  • Custom Energetics

    Excelitas Technologies Corp.

    Excelitas has extensive experience with designing, manufacturing, and testing a wide range of energetic components including actuators, detonators, initiators, and timers.  The products are manufactured to precise standards enabling high reliability and consistency from device to device.  The initiation mechanisms include exploding foil initiators (EFI), exploding bridge wire (EBW), and laser initiators.  Detonators, actuators, and timers are manufactured and tested as build-to-print products for the NNSA.

  • Photoluminescence & Electroluminescence Measurement System (PL/EL)

    PL - ZOLIX

    PL/EL Measurement System includes Laser, Spectrometer, Lock-in amplifier, Optical Chopper, Sample Holder(PL/EL), PMT/CCD, Fiber, Optical optics, Optical Table, Refrigerator(low temperature),Sample Chamber and related accessories;

  • Confocal FLIM System

    DCS-120 - Becker & Hickl GmbH

    *FLIM Upgrade for Existing Conventional Microscope*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*One or Two BDL-SMN or BDS-SM ps Diode Lasers*Two Fully Confocal Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Wideband Version, Compatible with Tuneable Lasers*Electronic Pinhole Alignment*Z-Stack FLIM Acquisition with Zeiss Axio Observer Z1*Optional: Spatial Mosaic FLIM via Motorized Sample Stage

  • Multiphoton FLIM System

    DCS-120 MP - Becker & Hickl GmbH

    *Multiphoton FLIM Upgrade for Existing Conventional Microscope*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*Excitation by Ti:Sa Laser*Two Non-Descanned Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Electronic Pinhole Alignment*Z-Stack FLIM Acquisition with Zeiss Axio Observer Z1*Optional: Spatial Mosaic FLIM via Motorized Sample Stage*Laser Control via SPCM Software

  • Hand-held Tachometers

    Shimpo Instruments

    SHIMPO offers a wide range of hand-held tachometers that measure the total number of revolutions of a shaft or number of pulses of reciprocating equipment. Our models can measure and record last/min/max and up to 10 reading using up to 16 different units of measure. Our tachometers are designed for applications such as Motor Speed/Conveyor Speed/Fan Speed/Length Measurements that measure rpm of motors or shafts, either contact or non-contact with Laser style combination tachometer.

  • Non-Contact Temperature Gun With Range Of -58℉~716℉

    AstroAI 380 - AstroAI Corp.

    ULTIMATE CONVENIENCE: It's never been easier or safer to take temperature readings in the kitchen, garage, during home repairs, commercial heating, ventilation, air conditioning(HVAC) installation and more thanks to Innovative IR Thermometer TechnologyENHANCED ACCURACY: The Distance to Spot Ratio is 12:1, making it easier to accurately measure temperatures from greater distances; An Integrated Laser assists with accurate aiming to better locate surface temperatures

  • Optical Wavelength Meters

    ADC Corporation

    Optical wavelength meter that uses a He-Ne laser as reference wavelength and employs the Michelson interferometer method, providing high-accuracy measurement. It can measure emission center frequencies of LDs for DWDM with high resolution and accuracy.The 8471 even provides a high sampling rate of 10 times per second, and is suitable for oscillation wavelength adjustment. In addition, its deviation display function allows wavelength variation to be measured with high resolution and accuracy.