Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 115 of 115 items found.

  • High Throughput 1 ns Pulsed IV Memory Test Solution

    NX5730A - Keysight Technologies

    Precise and fast characterization of new memory, such as spin transfer torque magneto resistive random access memory (STT-MRAM) from DC to high-speed pulsed IV measurement on silicon wafers Apply accurate and high-speed pulsed voltages (down to 1 ns pulse) to magnetic tunnel junction (MTJ) for STT-MRAM and precisely measure the resistance of MTJ Perform all typical MTJ characterization tests in one solution10 to 100 times faster cycle test, such as a bit error rate test (BERT)Capture and visualize MTJ switching waveforms clearly during the writing pulse Dedicated solution with Keysight Technologies’ technical expertise

  • PIN Photodiode

    Appointech, Inc.

    PIN photodiode is a kind of photo detector, it can convert optical signals into electrical signals.This technology was invented in the latest of 1950's. There are three regions in this type of diode. There is a p-region an intrinsic region and an n-region. The p-region and n-region are comparatively heavily doped than the p-region and n-region of usual p-n diodes. The width of the intrinsic region should be larger than the space charge width of a normal p-n junction. The PIN photo diode operates with an applied reverse bias voltage and when the reverse bias is applied, the space charge region must cover the intrinsic region completely. Electron hole pairs are generated in the space charge region by photon absorption. The switching speed of frequency response of photo diode is inversely proportional to the life time. The switching speed can be enhanced by a small minority carrier lifetime. For the photo detector applications where the speed of response is important, the depletion region width should be made as large as possible for small minority carrier lifetime as a result the switch speed also increases.

  • pHTestr® 30+ Waterproof Pocket Tester

    OAKTON Instruments

    Waterproof pHTestr 30 is great for outdoor applications such as taking pH measurements in lakes and streams. Designed to float in water, you can even attach a line to the housing for easy retrieval. Valox sensor housing resists most chemicals.The pHTestr 30 has a replaceable sensor for easy maintenance. pHTestr 30 purchased before Oct. 2019 use replacement sensor 35624-38. pHTestr 30 purchased after Oct. 2019 use replacemenr sensor 35634-03. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage.The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include a automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.

  • WEIGHING SYSTEM TESTING

    1006 - Pavone Sistemi S.r.l.

    The Tester 1006 has a simultaneous control function of up to 4 load cells in any weighing system, upload and download function for programming the DAT and MC 302 series instruments, but it can also be used as a Calibrator and Peak detector. It is very useful for the correct mechanical installation and for fault diagnosis. The Tester 1006 is supplied as standard with cable for connection to our junction boxes / sum mod. CEM 4 / C and CGS 4 / C. Simultaneous display of the signal of each individual load cell allows to control the entire weighing system, weight distribution, overloads, faulty cells and faulty connections. OUT OF PRODUCTION. Pavone systems provides a new version of Tester 1006: Tester 1008.

  • Thermal/Multi-Function Data Logger

    51101 - Chroma Systems Solutions, Inc.

    Models with 1, 8, and 64 channels on-line data recording. Multi-sets linked to a PC for hundreds of channels are doableSupports B, E, J, K, N, R, S, and T type thermal couples with ITS-90 defined temperature rangeIndividual channel cold junction compensation withTemperature resolution up to 0.01℃, error down to (0.01% of reading+0.3℃)Voltage full range ±480VDC, ±10VDC; resolution 1mV, 10uV; error down to (0.1% of reading+1mV), (0.015% of reading+100uV)1000VDC channel to channel isolation, full protection for testing points with charge and guarantee for accurate measurementsThermal couple open circuit detectionPC-based operation with powerful software for recording and analyzing data1 and 8 channel models are USB powered. No battery or external power supply is required

  • REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O

    784750-01 - NI

    4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.

  • Waveguide Detectors 26.5 to 110 GHz

    Fairview Microwave Inc.

    Our waveguide detectors cover a broad frequency range of 26.5 GHz to 110 GHz and are available with waveguide sizes ranging from WR-28 to WR-10. The video output ports utilize SMA female connectors. These high performance zero-biased waveguide detectors exhibit excellent performance in Ka, Q, U, V, E and W frequency bands. These types of waveguide detectors are commonly used in various aerospace, defense and commercial wireless applications used in instrumentation, power detection, power monitoring, direct detection receivers, high frequency communications, radar, SATCOM, point-to-point radio, telecom, data links and R&D. The detector circuits use high performance GaAs Schottky Barrier Beam lead diodes with extremely low junction capacitance. These waveguide detector designs perform with minimal sensitivity variation resulting in a flat frequency response across the entire waveguide band. All of the waveguide detectors are in-stock and ready to ship.

  • Multifunction Electrical Installations Meter

    MPI-502 - Sonel S.A.

    Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling

  • Temperature Data Acquisition

    THERMES-USB - Physitemp Instruments

    Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)

  • Temperature Data Acquistion

    THERMES-USB RF - Physitemp Instruments

    Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.