Filter Results By:

Products

Applications

Manufacturers

Inductance

emf generated to oppose a given change in current. http://hyperphysics.phy-astr.gsu.edu/hbase/electric/induct.html

See Also: Inductor, EMF, Current


Showing results: 121 - 135 of 149 items found.

  • 48 Ω HMM Pulse Force Probe

    PHD-HMM-48-1 - High Power Pulse Instruments GmbH

    *High current wafer-level and package-level 98 Ω HMM probing with grounded DUT*Built-in high surge 48 Ω pulse reflection suppression resistor up to 80 A peak*Fast rise time < 0.5 ns due to low inductance GND loop*Variable pitch from 50 µm to 5 mm*Tungsten replacement probe tips*SMA pulse force pigtail*Compatible to PHD-3001A interface*High reliability

  • Grypper G80 / G80 LIF

    Ironwood Electronics

    *Package-size PCB footprint: Since the PCB footprint of G80 is identical to the package, only one PCB design is required, enabling a seamless transition from test and validation through production and reducing overall cost of test*Low insertion force: Unique contact design reduces the insertion force required to insert and retain higher-ball-count packages safely and securely within the test socket*No lid required: The package snaps directly without a lid, enabling easy probing, scoping and troubleshooting the topside of the device*Excellent signal performance: A short signal path achieves low inductance and low insertion loss, providing a nearly invisible electrical connection

  • Single Phase Impulse Winding Tester 3 kV

    SME1203 - Scientific Mes-Technik Private Ltd

    Single Phase , 3 kV Impulse winding testing Low inductance impulse test: down to 10 μH Low energy test without damaging the coil Fast detection of winding insulation at a speed of 5.5 Meas/sec 4 kinds of waveform comparison methods Up to 40 MSPS sampling rate 320×240 dot-matrix graphic LCD display Multi-trigger mode programmableVoltage, Time and Frequency measuring functions Direct display of comparison result

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Harmonic Filter Resistors

    Post Glover

    Post Glover designs, builds and tests their harmonic filter resistors in accordance with applicable IEC and IEEE standards to guarantee their performance. With no two installations ever being the same, our experienced engineers develop the proper solution for your particular application and environment. Our low inductance designs are built using all stainless steel elements in corrosion resistant enclosures chosen for your unique specification. Request a quote for your custom harmonic filter resistor.

  • Repeated Charge Discharge Test Set

    Sivananda Electronics

    The IS 13341 : 1992 has laid down the requirements for Ageing Test, Self-Healing Test and Destruction Test on Shunt Capacitors of the self healing type for AC Power Systems. The Ageing Test is to be performed at a specified voltage of 1.25 times the rated voltage for 750 hours. The test is to be followed with a repeated discharge cycle test which involves charging of the capacitor to a DC voltage and discharge of the same through an Inductance. Sivananda Electronics has developed this equipment for the benefit of capacitor manufacturers, for the first time in India.

  • Socket /Contactor

    Verticon® 100 BGA - Johnstech International Corporation

    The Verticon® 100 BGA socket /contactor is an elastomer based contactor technology featuring a combined contact profile, and proprietary plating, and solid contact dynamics providing low inductance and stable contact resistance under multiple (production) landing test conditions. The overall design architecture of the Verticon® 100 contactor enables functional test hardware interface compliance as required by precision analog/mixed signal, high speed digital and RF SOCs’ up to the millimeter wave frequency domain.

  • Precision Metal Clad Shunt Resistor

    IRHF - RARA Electronics Corporation

    Precision Metal Clad Resistors designed in four- terminal technique, are distinguished by high load capacity as well as excellent accuracy. Isolated voltage and current connections making them suitable for very precise current measurements. Easy current measurement is performed by attaching to current bus directly and connecting to voltage (ampere) metal through flexible wires. The ULH models are UL approved versions. Units have a low inductance, heavy copper terminals. The main application is battery manufacturing test jig.

  • ST2817B+ LCR Meter (50Hz to 100kHz, 10 points))

    Saluki Technology Inc.

    ST2817B+ LCR meter is a high-performance and cost-effective measuring instrument. It can automatically measure the inductance L, capacitance C, resistance value R, impedance modulus |Z|, quality factor Q and loss tangent value D and other component parameters. The instrument combines powerful functions, superior performance and simple operation, which can not only meet the needs of high-speed measurement on the production site, but also meet the needs of precision testing in quality inspection, measurement, scientific research and experiment departments.Applications: Passive component / Other component

  • AC Resonant Test System

    Yangzhou Power Electric Co., Ltd

    Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.

  • Battery Analyzers

    BA6010 Series - B&K Precision Corporation

    The BA6010 Series battery analyzers measure voltage and resistance of modern battery technologies with high accuracy, resolution, and speed. Additionally, these instruments provide auxiliary measurement parameters inductance, capacitance, dissipation factor, impedance, quality factor, reactance, and phase angle in degrees and radians. The BA6010 Series is suitable for characterizing battery chemistries that are responsive to a 1 kHz AC stimulus signal including lead acid, lithium and alkaline type batteries used in consumer products, electric vehicles, power backup, security, and fire alarm systems.

  • Uni-Therm High Current Electrosurgical Analyzer

    Seward Medical

    A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.

  • Chroma LCR Meters

    Chroma Systems Solutions, Inc.

    Some of the key features to look for in an LCR meter (also known as an impedance meter) are: accuracy, test frequency, measured parameters, test voltage and test current. Additionally, an easy to understand display of test results and the ability to access and use these results has become increasingly important. Component testing often requires much more than simply a resistance, capacitance or inductance value at a given test frequency and stimulus voltage. An LCR meter or impedance meter must have the flexibility to provide multi-parameters over wide frequency and voltage ranges.

  • General Purpose Basic Carrier Demodulator

    CD15 - Validyne Engineering

    The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.

Get Help