Filter Results:
Products
Manufacturers
Applications
High Frequency
High Frequency operating at 3–30 MHz.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
High Frequency Probe
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
High Frequency Probe
Your product description goes here.
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
High Frequency Modules
-
Digital Signal Technology, Inc.
Modulators, frequency dividers, amplifiers, filters, etc.
-
Product
High Frequency/Microwave
-
SemiProbe high frequency probing solutions provide a broad array of capabilities for measurements ranging from DC to over 300 GHz. We design PS4L systems for high frequency applications with carefully selected components including chucks, probe arms, probes, cables, tuner modules, and calibration suites that are optimized for the frequency range that the application will operate in.
-
Product
MOSFETs For High Frequency Amplifier
-
The MOSFETs shown below are best suited for amplification of high-frequency signals.
-
Product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
-
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
Product
High Frequency Coaxial Analytical Probes
-
D-COAX offers four analytical probe models: HyPac model for package characterization, and two models, Omni and OmniJet, for board level characterization, and DP1.4mm differential, single-ended probe.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Products for High-Frequency Measurement
-
This product range includes passive high-frequency test probes and accessories as well as touch-protected BNC plug connectors, insulated BNC panel-mount sockets, leads with RG58 or RG59 cable, adapters and converters. Our test probes are suitable for use in CAT III- and CAT IV environments (Measurement Categories), such as the analysis of house and building installations with mains analysis/mains monitoring devices. Our high-frequency accessories are designed with clearance and creepage distances in accordance with IEC/EN 61010-031.
-
Product
High Frequency Cartridge for HFP Series Probes
PACC-MS003
-
High Frequency Cartridge for HFP Series Probes
-
Product
High-frequency Induction Heater Unit
-
High-frequency induction heater unit is a high frequency generator for non-contact heating of metal using electromagnetic induction.
-
Product
High Frequency Current Transformer
HFCT
-
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
Product
High Frequency Noise Simulator
SKS-H04GA
-
Shanghai Sanki Electronic Industries Co., Ltd.
The high-frequency noise simulation generator is an EMC test instrument that reproduces high-frequency noise with a fast rise time when the switch is turned on/off. Since the pulse rise time is less than 1ns and contains wide bandwidth noise, it is very suitable for reproducing malfunctions. The line noise entering the power line and the induced noise entering the communication line can be reproduced, and the performance evaluation of the malfunction and function degradation of electronic products can be performed.
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
MOSFETs For High Frequency Amplifier
-
The MOSFETs shown below are best suited for amplification of high-frequency signals.
-
Product
High-Frequency Probe, 300 kHz to 3 GHz
85024A
ICT/FCT Probe
85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.
-
Product
High-Frequency Signal Amplifier
VCH-605
-
High-frequency signal amplifier VCH-605 is designed to amplify and multiply sinusoidal signals with a frequency of 1-100 MHz.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
LXI High Frequency Matrices
-
Pickering's LXI high frequency (HF) matrix modules are suitable for switching frequencies up to 50MHz. They have an impedance of 50 and uses SMB signal connectors or with a larger case size is uses BNC connectors. This HF matrix is designed to provide a simple and scalable bidirectional matrix for radio frequencies and is intended for the easy construction of high performance bidirectional matrix switching systems.
-
Product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
High Frequency Probe
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.





























