Showing results: 46 - 60 of 335 items found.
-
M1971V -
Keysight Technologies
Keysight M1971V 50 to 75 GHz waveguide harmonic mixer is an un-preselected mixer that provides a complete solution for wideband millimeter-wave signal analysis of more than 2 GHz with X-Series signal analyzers. Embedded smart features help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
PA920 -
Vitrek Corporation
The new PA920 is the most powerful, accurate and flexible power analyzer available on the market today available with 0.024% power accuracy. These new products provider faster sampling rates, bandwidth performance and greater harmonic frequency, yet still easy-to-use and affordable.
-
PA910 -
Vitrek Corporation
The PA910 power analyzers offer expanded power analysis options. The PA910 offers ultra high 0.045% power accuracy for all channels and improved voltage and current self-heating adders over those of other power analyzers. In addition, the PA910 provides easy channel selection for the user while offering 100 full precision readings per second and measurement bandwidths sufficient to handle 5 MHz waveforms.
-
2745 -
Kusam Electrical Industries Limited
Power measurement of Active power (KW), Reactive power (KVAR), Apparent Power (KVA). Power Factor (PF) for 3 Φ 4W, 3 Φ 3W, 1 Φ 2W, 1 Φ 3W
-
Extech PQ3350-3 -
Extech Instruments Corporation
Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.
-
Extech PQ3350-1 -
Extech Instruments Corporation
Complete with 1200A 12" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case
-
HA1600A -
Aim-TTi
Compliance quality measurements to EN61000-3-2 and EN61000-3-3Measures peak or rms voltage or current, real or apparent power, power factor, phase etc.Tabular/histogram of 40 harmonicsVoltage/current waveforms displaysContinuous analysis with real-time graphical updateWide range of power connectors available320 x 240 pixel high-contrast displayUSB, RS232 and printer interfaces fittedPC control and documentation software supplied (HA-PC-Link+)
-
Harmonic Vibration -
ZETLAB Company
The Harmonic vibration program is intended for harmonic oscillations resistance testing within the specified frequency range or at a fixed frequency during the set time interval.
-
Harmonic Distortion Analysis -
ZETLAB Company
The software is used for automatic measurement of the harmonic distortion factor and voltage r.m.s. of signals coming to the input channels of FFT spectrum analyzers. Adjustment to the frequency of the main component is performed automatically. The program is based on the measurement of the voltage r.m.s. of higher components by an external or internal reference signal.
-
Hilkar
LCL Type Harmonic Filter Modules are used to filter out the input current harmonics of the Motor Drives having six-pulse diode/thyristor rectifiers, where harmonic current distortion exceeds the limits defined in standards.
-
-
MPR1 Series -
Entes Elektronik
CurrentNeutral currentVoltage (Phase to Phase, Phase neutral)Active, Reactive and Apparent powerFrequencyActive PowerReactive PowerApparent PowerCos φPower FactorTotal Active PowerTotal Reactive PowerTotal Apparent PowerTotal Cos φTotal Power FactorTotal Harmonic Distortion of the CurrentTotal harmonic distortion in current from phase to phaseTotal harmonic distortion in neutral current from phase to phase
-
S96082A -
Keysight Technologies
The S96082A offers the solutions for measuring mixers/frequency converters and amplifier's harmonics using the ENA. The frequency offset mode (FOM) provides the capability to tune the ENA's receivers to different frequencies from the source. This enables measuring amplifier's harmonic responses and mixer/converter's conversion loss.
-
UI2001B -
Lisun Electronics Inc.
• Measure input parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components. V range: 10.0~300.0V, A range: 0.010~2.000A, F range: 45~65Hz • Measure output parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components Lamp voltage range: 10.0~450.0V, Lamp current range: 0.010~2.000A • Accuracy: ± (0.4% reading+0.1% range+1 digit) • Can test every kind of curve, print both data & curve • Communication interface available for PC, running under Windows98/2000/XP/Vista
-
Pacific Millimeter Products
A series of broadband frequency multipliers is available with output frequencies between 18 and 110 GHz. The use of GaAs diodes on a suspended substrate circuit allows an extremely compact device. Circuit symmetry is used to enhance either even or odd harmonics while suppressing unwanted odd or even harmonics. These devices can be used as higher order even or odd harmonic multipliers with reduced efficiency. All of these multipliers have maximum input power +23 dBm for temperature less than +50°C.