Filter Results By:

Products

Applications

Manufacturers

Harmonic

Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.


Showing results: 331 - 335 of 335 items found.

  • Function Generators

    Shanghai MCP Corp

    Respective dual channels function/arbitrary waveform generator. Sine wave output up to 160MHz, full-band resolution of 1μHz. Pulse waveform up to 50MHz (or 40MHz), adjustable time of rising, falling and duty ratio. Sampling rate of 500MSa/s and vertical resolution of 16bit. 6-bit high-precision frequency meter compatible with TTL level signal. Arbitrary wave storage of 8~32M points, 7GB non-volatile waveform storage. Multi modulation function::AM,FM,PM, ASK,FSK,PSK, BPSK, QPSK,OSK,PWM, QAM, SUM . 16bit digital arbitrary wave (TTL level) DARB. 16th Harmonic Generation Function. Protocol output: I2C, SPI, UART (TTL level). 8 Inch high-resolution TFT color LCD,WVGA(800×480). Standard interface: USB Host, USB Device, LAN, 10MHz clock source input/output. Frequency sweep and burst output. Easy-to-use multi-functional knob and numeric keypad

  • 40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger

    SD750100G - Zhejiang Sandi Electric Co., Ltd

    40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%

  • Automated Tuners / Impedance Tuners / Load Pull Tuners

    Maury Microwave Corporation

    MT97x, MT98x and XT98x series automated tuners (also known as automated impedance tuners and automated load pull tuners) are precision instruments that are optimized for a broad class of in-fixture and on-wafer applications, and may be used in any automated or manual application requiring the ability to match the impedance of a microwave circuit element or to establish specific impedances at a terminal interface. The tuner design is based on the slide screw concept using the inherently broadband slab-line transmission structure. Each unit has two non-contacting probes deliver high VSWR with superb accuracy and reliability over a wide frequency range. These probes can be fully retracted leaving a low-loss, well-matched transmission line, which is a significant benefit in power related applications where two-port tuners capable of handling large amounts of power are required. As integral components of Maury Device Characterization Solutions, these PC-based tuners are controlled using Maury's family of Device Characterization Software tools, including MT930 IVCAD, MT993 ATS and the DLL-based measurement automation environment. Maury Microwave automed impedance tuners are ideal for load pull, harmonic load pull, active load pull, hybrid active load pull, noise figure, noise parameters and all automated tuner applications.

  • Dual-Channel Precision Audio Analyzer with Built-In Condenser Measurement Mics

    PAA6 - Phonic Corporation

    Essential tools, such as the Phonic PAA6 Professional Audio Assistant generally wind up at the bottom of pro audio wishlists after esoteric preamps, compressors, and EQs. But more often than not, the key to great sound lies in the utilitarian gear, particularly, the Phonic PAA6 audio analyzer. If you want to get the most out of your studio equipment or PA system, the PAA6 should be at the top of your bucket list. A highly accurate measurement tool, the elegant touch screen interface of the PAA6 offers unfettered access to 61-band real-time spectrum analysis; Fast Fourier Transform (FFT); sound pressure (SPL) and dBu/dBV line voltage measurement; EQ setting; phase and polarity check; LEQ (equivalent continuous noise level); audio oscilloscope; and RT-60 functions. The PAA6 also has two built-in condenser measurement mics that can be used in six different positions. If sound is your product or passion, the Phonic PAA6 is perhaps the wisest investment you can make for your studio or sound reproduction system. Whether you're setting up monitors, treating room characteristics, calibrating listening levels, or want to know the harmonic distortion and noise characteristics of your workhorse preamps to ensure clean mixes, the Phonic PAA6 is your key to the best possible quality sound.

  • Power Phase Converter Single phase 220VAC to 3 phase 380VAC Converter

    SDT-40KW - Zhejiang Sandi Electric Co., Ltd

    SANDI SDT series single-phase to three-phase converter, adopted SVPWM modulation control technology, which can convert ordinary single-phase power to industrial three-phase power. After through SDT series single-phase to three phase converter power conversion, the three-phase power output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards of three-phase power quality, applicable to all types of load.The SDT series single-phase to three-phase converter can solve production inconvenience because of some areas with the three-phase electric power restrictions, also solved some user requirements that can?謒?apply for the three-phase electric because of space limitation.Features1) Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It's service life can up to 15 years or more.2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter?謒?usage, which reduced the cost of equipment investment, easy to connect wires and control.3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage.4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference.5) Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load.7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices.8) Output perfect protection function, with output over-voltage, overload, short circuit, over temperature, self-diagnosis protection and other protection.9) High conversion efficiency, high instantaneous power and low load loss.10) The input voltage, output voltage, frequency and phase can be custom made.SpecificationModel SDT-40KWIsolation mode Low Frequency TransformerAC InputRated voltage (Vac) 240V single-phase 60HZVoltage range (Vac) 190-270VInput current (A) 167AAC OutputRated power (KW) 40KWRated voltage 240V ± 2%Output phases Three-phase with Neutral wires (L1, L2, L3 + N)Rated current (A) 96AOutput frequency 60Hz ±0.05 (50HZ can be set)Waveform Pure sine waveVoltage accuracy Load balancing≤1%、Unbalanced load≤5%Waveform distortion rate (THD) Linear load≤2%、Nonlinear load≤3%Dynamic Response 5%,≤50ms (load 0~100%)Power Factor (PF) 0.99Inverter Efficiency ≧85%Electrical insulation properties 2000Vac、1 MinuteProtection FunctionOverload Ability 150%、10sProtection Input under voltage, overvoltage, output over-current, short circuit, overheating etc.Display LCD+LEDMethod of working Working continuouslyCooling method Intelligent fan coolingShort-circuit protection No automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protection IP20 (indoor)Working Altitude(m) ≤3000mWorking temperature (℃) -20~+50℃Relative humidity (℃) -25~+85℃Noise (1 meter) ≤60dBReference size: (W x D x H) 750×750×1480mmReference net weight (Kg) 340Kg

Get Help