PM7503 -
Outram Research Ltd (ORL)
The PM7503 Power Quality and Energy Monitor is a panel mounted variant of our top of the range PM7000 Power Quality Analyser. As with the PM7000 and P7000FLM, as well as recording all other important power quality parameters, the PM7503 with the optional Interharmonics upgrade is able to record 100 Voltage or Current harmonics on all 4 inputs at the same time.
-
ALCL-40 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
ALCL-40H -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
North Atlantic Industries
NAI designs and manufactures a wide variety of self-contained, remotely mountable, Signal Converter Modules:*Synchro/Resolver Booster AmplifiersS*ynchro/Resolver Converters*ARINC 429-to-Synchro Converters*Second Harmonic Fuel Flow ConvertersTheir field-proven designs and carefully selected components assure highly reliable performance. These military grade modules are specifically designed for rugged defense and industrial applications.
-
TCM-1A -
Macintyre Electronic Design Associa
The TCM-1 is a three-channel portable signal conditioner specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from either its internal batteries or the power line. It incorporates two sets of power line rejection filters, switch selectable for 50 or 60 Hz and the corresponding first four harmonics.
-
AK-6 -
Amperis sl
*5 automatic or manual test modules: DC test, AC test, distance test, harmonics and frequency protection*Phase, frequency and amplitude are continuously and independently adjustable.*All-in-one design: built-in Windows CE & rotary encoder & keyboard & 6.4" TFT LCD (RJ45/USB for updates and downloads)*High power: 3x450VA at 0...35A average voltage test
-
SPS-50 -
Kongter Test & Measurement Co., Limited
SPS-50 standard power source is applied for various tests of analog and digital AC voltage meter and current meter, single/three phase active and reactive power meter, phase angle meter, single/three phase power factor meter, frequency meter, and synchronous-meter, single/three phase active and reactive power meter. It also output 2nd ~63rd harmonics.
-
Qualstik -
SensorLink
The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.
-
DP Series -
PRANA
Class A solid stateBroadband (instantaneous single band): 10 kHz 250 MHzTypical output power : 1000 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB>600 W and H<-20 dBcAir cooling: self contained fansCan operate in full mismatch conditions without damageReliable, efficient and robust19" Cabinet on wheels3 years standard warranty
-
En Technology
The mAEStro AADC-100 accepts balanced stereo analog audio inputs and converts them into a single digital bit stream in compliance with the AES/EBU (AES3) and S/PDIF digital audio standards. It generates 24-bit values and uses 128 times over-sampling for extremely accurate and linear analog to digital conversion, as well as offering a high dynamic range with exceptionally low total harmonic distortion and noise.
-
STMicroelectronics
The RF integrated passive device (RF IPD) uses a high-resistivity substrate to integrate quality factor components such as capacitors and indictors. Many functions like impedance matching networks, harmonic filters, couplers, baluns, and power combiners/splitters can be designed using IPD technology. ST's IPDs are manufactured using thick film and HiRes Si or glass wafer manufacturing technology and photolithography processing.
-
SAM-3 -
Macintyre Electronic Design Associa
The SAM-3 is a portable single channel signal conditioneer specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from eitherits internal batteries or the power line. It incorporates two sets of power line rejection fileters, switch selectable fro 50 to 60 Hz and the corresponding first four harmonics.
-
iSTAT M355 -
GE Grid Solutions
The iSTAT M355 is a Power Quality Analyser that provides measurements to IEC 61000-4-30. 2008 Class A and reports Power Quality compliance to EN50160: 2011. Sampling at a rate of 31 kHz (620 samples per cycle at 50Hz) and true RMS measurement gives accurate readings under all harmonic conditions, with Measurement accuracy better than 0.1% and Class 0.2S Energy.
-
Flexible Coil Current Sensor -
MEET International Ltd.
*Analysis of harmonics, power measurements*Very high-current monitoring*Measuring starting transients of electric motors*Sudden short circuit testing*Arc furnace currents*High-current monitoring of switch-gear and fuses*Data logging*Can be measured by popular multi-meter
-
ACD-41PQ -
Amprobe Test Tools
The Amprobe ACD-41PQ provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.