Showing results: 166 - 180 of 324 items found.
-
DP Series -
PRANA
Class A solid stateBroadband (instantaneous single band): 10 kHz 250 MHzTypical output power : 1000 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB>600 W and H<-20 dBcAir cooling: self contained fansCan operate in full mismatch conditions without damageReliable, efficient and robust19" Cabinet on wheels3 years standard warranty
-
En Technology
The mAEStro AADC-100 accepts balanced stereo analog audio inputs and converts them into a single digital bit stream in compliance with the AES/EBU (AES3) and S/PDIF digital audio standards. It generates 24-bit values and uses 128 times over-sampling for extremely accurate and linear analog to digital conversion, as well as offering a high dynamic range with exceptionally low total harmonic distortion and noise.
-
SAM-3 -
Macintyre Electronic Design Associa
The SAM-3 is a portable single channel signal conditioneer specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from eitherits internal batteries or the power line. It incorporates two sets of power line rejection fileters, switch selectable fro 50 to 60 Hz and the corresponding first four harmonics.
-
iSTAT M355 -
GE Grid Solutions
The iSTAT M355 is a Power Quality Analyser that provides measurements to IEC 61000-4-30. 2008 Class A and reports Power Quality compliance to EN50160: 2011. Sampling at a rate of 31 kHz (620 samples per cycle at 50Hz) and true RMS measurement gives accurate readings under all harmonic conditions, with Measurement accuracy better than 0.1% and Class 0.2S Energy.
-
Flexible Coil Current Sensor -
MEET International Ltd.
*Analysis of harmonics, power measurements*Very high-current monitoring*Measuring starting transients of electric motors*Sudden short circuit testing*Arc furnace currents*High-current monitoring of switch-gear and fuses*Data logging*Can be measured by popular multi-meter
-
ACD-41PQ -
Amprobe Test Tools
The Amprobe ACD-41PQ provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.
-
DG1000Z Series -
Rigol Technologies Inc.
DG1000Z series function / arbitrary waveform generator is a multi-functional signal generator which integrates function generator, arbitrary waveform generator, noise generator, pulse generator, harmonic generator, analog / digital modulator, frequency meter and other functions.
-
Vishay Intertechnology, Inc.
Vishay ESTA is one of the few manufacturers to offer a complete range of power capacitors. These cost-effective devices for harmonic control, energy savings, and voltage stabilization are highly reliable and environmentally safe, and can be used under the most rugged conditions. Vishay ESTA power capacitors address a wide range of energy-generation applications. Their “green” applications include energy generation in on- and off-shore wind turbines and solar power plants.
-
7 Series -
Powermetrix Systems
We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.
-
SPM Series -
Farran Technology Ltd
Farran offers fundamental (RF ≈ LO), sub-harmonic (RF ≈ 2xLO) and harmonic mixers (RF≈NxLO, where N=2, 4, 6 …) for a wide variety of applications from 26.5 GHz to 500 GHz. All mixers use planar Schottky diodes and provide state of the art performance in a small and lightweight package.High-performance sub harmonically pumped mixers are available in frequencies from 50 to 350 GHz and beyond.
-
T&C Power Conversion
100 W to 2400 W 13.56 MHz Analog/Digital, RS-232, USB interfaces Low Harmonic Distortion Automatic and Manual Gain Control High Speed Pulsing (Bursting) controls Compatible with T&C''''s Matching Networks GUI Software (complete PC control) Includes all essential RF power/communication cables and mounting brackets Air cooled (Air & Water 1200 W +) Half rack mount or stand alone versions Ideal for: Industrial, Scientific, and Medical Applications
-
SPC70 -
Martindale Electric Co. Ltd
The SPC70 is a Class 2 sound level calibrator suitable for periodic testing of sound level meters and verifying their accuracy before and after readings, in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB. The output is accurate to 0.5dB with low levels of harmonic distortion. The SPC70 is compatible with the Martindale SP79 Class 2 Sound Level Meter and other meters with microphones up to 25mm.
-
4016(800Vp,20Arms/200Ap) -
PRODIGIT Electronics Co, Ltd.
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
ITS-9050 -
Innovative Technical Systems
The Innovative Technical Systems ITS-9050 Detector is a sensitive, harmonic mixing detector designed to measure millimeter-wave free-space radiation. It is ideal for measuring radiation patterns of antennas inboth the near and far-field. The ITS-9050 employs a free-running dielectric resonator oscillator (DRO) and an integrated harmonic mixer with a waveguide RF input that either connects directly to a circuit under test or to an antenna for radiation detection. The resulting IF is amplified and detected by an IF log-detector that drives a front panel LCD voltmeter to provide an indication of signal strength. A DC output voltage from the log detector is available on a BNC connector to drive external data acquisition instrumentation. Also, a sample of the IF output is provided for measurement on a spectrum analyzer.
-
BL1350 Series -
Behlman Electronics Inc.
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.