Filter Results By:

Products

Applications

Manufacturers

Experiments

test of hypothesis to learn.

See Also: Data Analysis


Showing results: 226 - 240 of 248 items found.

  • MassLynx Mass Spectrometry Software

    Waters Corporation

    The challenges of MS and MS/MS analyses are often compounded by the use of several types of analytical instruments and high personnel turnover. To maintain – and even increase laboratory productivity, turn to Waters software to simplify interaction with your MS system and retain the ability to perform advanced experiments. Waters MassLynx™ Software improves your MS system with its intuitive interface, intelligent instrument control, and software features built around the focus of your analysis: the sample. With much of its development driven by input from our extensive user base, MassLynx has evolved into a powerful software package that delivers the versatility and flexibility you require.

  • Optogenetics

    Thorlabs, Inc.

    Thorlabs offers a line of optogenetics equipment that allows for in vivo optical stimulation for neuroscience research. We currently offer a large selection of optogenetics supplies, including implantable fiber optic cannulae with ceramic or stainless steel Ø1.25 or Ø2.5 mm ferrules, available both cleaved and scissor-cut. We offer lightweight multimode patch cables with an optional rotary joint. They have ferrule ends for mating to our cannulae using an interconnect or ceramic mating sleeve. A separate 1x1 rotary joint that accepts FC/PC multimode patch cables is also available. Cannula holders and implant guides provide additional stability and accuracy when implanting cannulae. Our optogenetics kits provide all the necessary components for an optogenetics experiment including LED, patch cable, cannulae, and accessories. Customers can add, remove, or replace parts in these kits to customize the purchase for their needs. We also offer couplers/splitters, a 1x2 rotary joint splitter, fiber-coupled LED light sources, and a 473 nm fiber-coupled laser.

  • TOV Test System

    Shanghai Guantu Technology Co., Ltd.

    1. Safety protection: traffic light indication status, emergency stop and interlocking of the test product door2. Equipped with a computer, set the TOV power supply parameters through the software interface, and automatically test3. Equipped with alarm function, equipped with emergency brake switch, equipped with safety cover and door switch4. The computer interface displays real-time voltage and current data5. Automatically draw voltage and current waveforms, and can save the waveforms as BMP format pictures, which is convenient for editing experiment reports.6. Automatically record test time, test current, test voltage, etc., and save the recorded data to files7. Installation method: cabinet installation.

  • Windows-Based Software Suite for Rigaku's X-Ray Diffractometers

    SmartLab Studio II - Rigaku Corp.

    SmartLab Studio II is a new Windows®-based software suite developed for the flagship Rigaku SmartLab X-ray diffractometer that integrates user privileges, measurements, analyses, data visualization and reporting. Newly available for the MiniFlex, the modular (plugin) architecture of this software delivers state-of-the-art interoperability between the functional components. Just one click switches from measurement to analysis. Watch real-time scans from one experiment while simultaneously analyzing other data on the same desktop by selecting an appropriate layout. The software provides various analysis tools such as automatic phase identification, quantitative analysis, crystallite-size analysis, lattice constants refinement, Rietveld analysis, ab initio structure determination, etc.

  • Laboratory EM current meter / water level and wave height meter

    JFE Advantech Co., Ltd.

    ACM2-RS and ACM3-RS are 2-D and 3-D electro-magnetic current meters for laboratory experiments. The models provide digital output, a high-speed sampling rate and insusceptibility to electro-magnetic noise. ACH-600RS is a highly sensitive capacitance water level meters. With the new system, a maximum of four different sensors can be connected to the compact interface unit, enabling simultaneous recording on a personal computer. Additionally, the system can provide analog output as well as necessary. While conventional water level and wave height meters cannot be used near velocity sensors, our instrument can be as near as 5 cm without increasing noise, due to its special isolated circuit. The result is an innovative system that is capable of achieving highly accurate data.

  • Lightweight Hammershock Testing

    National Technical Systems

    Lightweight Shock Machine (LWSM) Testing per MIL-DTL-901E is the military specification covering shock test requirements for shipboard machinery, equipment, systems and structures. Anyone who produces an item for military use in any of these shipboard categories will likely need to complete this testing. The purpose of this testing is to verify the ability of shipboard installations to withstand shock loadings which may be incurred during wartime service due to the effects of conventional or nuclear weapons. These requirements grew out of the Navy’s experiences during World War II and the subsequent underwater explosion (UNDEX) experiments. In many cases, it was found that critical ship systems could be disabled by the shock effects of nearby weapons explosions that were not a direct hit on the ship itself.

  • Spectrographs & Monochromators

    ZOLIX

    Manual micrometer adjustable slits for precision control of incoming light. Motorized Slit and fixed slit is optional. More than 100 gratings for the best spectral range, throughput and dispersion to meet your applicationDSP controlled stepping motor scanning system provides superior precision and repeatability of wavelength positioningOptional internal shutter or six-position filter wheel for experiments requiring background removal or signal attenuationInstallation and set-up through USB 2.0 computer interfaces Stand-alone Omni Series monochromator control software for basic scanning and calibration. Also includes utilities for grating updates and communications Active X control support Visual Basic, C++ and Delphi drivers allow users to design their own acquisition programsZolixScan data acquisition software provides a simple user interface for easy data acquisition and experimental set-up

  • Photon Counting PMT Detection System

    HORIBA, Ltd.

    For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMTs are durable, long-lived, and economical.HORIBA provides a simple, self contained PMT housing that operates in either analog or photon counting modes with the flick of a switch. This ambient PMT housing is ideal for standard side-on PMTs that are used from 185 to 900 nanometers. It has a very low dark count for a non-cooled PMT housing providing a dark count of only ~ 50 to 500 counts per second (cps) depending on the PMT selected.

  • Audio Fiber Tracer

    CFT-810 - FiberPro

    Motorized Polarization Controller. In addition to its basic function of adjusting polarization states in multi channels, it also provides convenient ‘save and recall’ functions. As a Scanning PC, it provides very powerful ‘auto scan’ modes with variable scanning speeds. Polarization states can be manipulated by either manual adjustment or remote control (GPIB, RS-232) using two quarter-wave plates in each channel of the PC1600. Additionally, the auto scan mode of FIBERPRO’s Motorized Polarization Controller has been upgraded in LPC, and it shows another auto scan mode of four quarter-waveplates with higher polarization extinction ratio when connecting two channels at a high speed. PC1600 is an essential tool to complete fiber-optic, multi-channel measurement systems such as WDM/DWDM as well as R&D (i.e. PMD experiments), and manufacturing.

  • Dual Vapor Gravimetric Sorption Analyzer

    DVS Resolution - Surface Measurement Systems

    DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.

  • Signal And Image Processing Research

    The Phased Array Company

    TPAC solutions are ideal for research in signal processing applied to ultrasound. You need to be able to access to any parameter, implement a particular algorithm, and access to any data during the acquisition or postprocessing phase. TPAC provides you all of these. It can be applied to studies in signal processing, image processing, beamforming, machine learning, etc… Thanks to TPAC’s open platforms, you will be able to freely set the ultrasonic sequences, record the raw data from your experiment, and test your own algorithms or even method. In order to adapt to a wide variety of habits, TPAC proposes multiple APIs (Application Programming Interface) compatible with Matlab, C++, Python, C#, Labview and working under Windows or Linux operating systems. Through a socket, it is even possible to use any OS of your choice.

  • Counter Electrodes

    ALS Co., Ltd

    For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.

  • SQUID Magnetometer

    S700X - Cryogenic Ltd.

    The S700X SQUID Magnetometer is the most sensitive instrument for DC and AC measurement of magnetic properties as a function of magnetic field and temperature. Numerous different experiments may be performed with this unique instrument. The SQUID sensor at the heart of the system has an input noise power sensitivity of approximately 10-30 Joules per root Hz. This energy sensitivity is 108 better than any semiconductor device and accounts for the instrument's ability to resolve extremely small magnetic signals with accuracy and speed. The S700X has several modes of operation. The most widely used is the measurement of total magnetic moment made by moving the sample through a set of pick-up coils. During the measurement the sample temperature and applied magnetic field are precisely controlled. The second order gradiometer configuration used for the pick-up coils is insensitive to the externally applied field but allows samples of 10-11 Am2 total moment to be resolved with ease.

  • Cold Atomic Beam System

    AOSense

    Detailed description of item: Complete cold atomic beam sources for alkaline-earth precision experiments and atomic devices. Small chambers with patented permanent-magnet Zeeman slowers and in-vacuum 2D MOT optics allow high flux with low outgassing and no thermal beam flux at the cold atom port, which provides a CF-133 connection to customer vacuum chamber. Advanced thermal design of the effusion oven allows long-lifetime operation at minimal heating power, with no water cooling. An integrated low-outgassing hot window is provided for coupling of on-axis Zeeman cooling light. Ion and getter pumps integrated into the chamber manage outgassing from the oven at temperatures up to 520 °C. Operating baseline pressures below 1×10-11 mbar can be attained in the customer’s downstream cold atom (typically 3D MOT) science chamber, with suitable pumping speed provided at the differentially-pumped cold beam output port.

  • Omni-λSeries Imaging Spectrograph

    Omni-λi - ZOLIX

    Zolix Imaging Spectrometer includes different focal length 320mm, 500mm, 750mm; ◆Manual micrometer adjustable slits for precision control of incoming light. Motorized Slit and fixed slit is optional. • More than 100 gratings for the best spectral range, throughput and dispersion to meet your application◆DSP controlled stepping motor scanning system provides superior precision and repeatability of wavelength positioning◆Optional internal shutter or six-position filter wheel for experiments requiring background removal or signal attenuation◆Installation and set-up through USB 2.0 computer interfaces • Stand-alone Omni Series monochromator control software for basic scanning and calibration. Also includes utilities for grating updates and communications◆ Active X control support Visual Basic, C++ and Delphi drivers allow users to design their own acquisition programs◆ZolixScan data acquisition software provides a simple user interface for easy data acquisition and experimental set-up

Get Help