Showing results: 3136 - 3150 of 3644 items found.
-
RM 1 -
Beck Elektroakustik
Using the RM 1 Tube Checker it is immediately possible to do an exact plate current measurement without doing the often very toilsome procedures mostly necessary with classical devices. Put the electron tube, which should be measured, simply into the accordingly marked test socket, switch the equipment on, select the socket by using the rotary switch (it is indicated by a LED), wait for approx. three minutes till the tube is working stabile and read off the value on the panel meter.
-
M9157CH40 -
Keysight Technologies
M9157CH40 operates from DC to 40 GHz, providing a low-cost operation switching solution for measurement and automation of Automatic Test Equipment (ATE) systems without compromise in the RF performance. It is being used in applications such as ATE, RF communication and RF parametric measurements where a rugged switching module is needed for signal routing. Typical switching applications for multiport coaxial switches include signal routing to a single input - to multiple instruments and routing of multiple input signals.
-
Signals & Systems India Private Limited
Large Display indicator measures and displays frequency from the input like supply voltage, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Frequency. The large display is for clear visibility of the frequency reading from long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct frequency measurements of various devices.
-
M9157C -
Keysight Technologies
M9157C operates from DC to 26.5 GHz, providing a low-cost operation switching solution for measurement and automation of Automatic Test Equipment (ATE) systems without compromise in the RF performance. It is being used in applications such as ATE, RF communication and RF parametric measurements where a rugged switching module is needed for signal routing. Typical switching applications for multiport coaxial switches include signal routing to a single input to multiple instruments and routing of multiple input signals.
-
N5700 Series -
Keysight Technologies
The Keysight N5700 Series delivers low noise power in a compact 1U package. Airflow moves front to back, so no additional space is required above or below the power supply in your automated test equipment (ATE) rack. Select output voltages from 6 to 600 V. For low current applications, the 750 W models provide 1.3 to 100 A. For higher current needs the 1500 W models provide twice as much current.
-
Data Patterns Pvt. Ltd.
The Generic RF ATE is developed to test the Radar and Radar Subsystems. The ATE is primarily built using an instrumentation control, precision RF routing systems and rack mounted test instruments. Generic RF ATE system enables measurement of parameters of Radar equipment such as Local Oscillators, Waveform Generators, Up and Down Converters, Analog Receivers, Array Group Receiver Units, TR Modules. The ATE is configured to test the Radars upto 18GHz frequency range.
-
VOLTCHEK -
Taurus Powertronics Systems
The VOLTCHEK is a variable non-contact voltage detector, A proximity device which detects the presence of an alternating electric or electromagnetic field. It is used by industry professionals for live or dead voltage determination of outdoor overhead or underground at URD test points. Firstly as a proximity device to determine live or dead situations and then as a touch device to verify the source has physically reached the zero AC field. This is the only equipment capable of testing all voltage from AC 415V to 765kV from a distance, beyond arcing zone.
-
CS1-RS -
Chuan Sheng Electronics Co., Ltd.
CS1-RS economic type Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm(2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
CS1-PM -
Chuan Sheng Electronics Co., Ltd.
CS1-PM economic type Potentiometer Indicator has been designed with high accuracy measurement, display and communication of resistance (3 wires) as like as Positioner.The meter supports Field Calibration function. It can be calibrated with sensor (Potentiometer) to meet machinery structure.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
CS2-PM -
Chuan Sheng Electronics Co., Ltd.
CS2-PM Potentiometer Indicator has been designed with high accuracy measurement, display and communication of Ohm (3 wire) as like as Positioner.The meter supports Field Calibration function. It can be calibrated with sensor (Potentiometer) to meet machinery structure.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
ViTec Co. Ltd
The hardware part of the measuring system of the test bench is built on the basis of equipment from National Instruments and contains the following components: multichannel switching system for signal conditioning SCXI, interrogation system of "fast-changing" voltage signals and AC power PXI, including M-series NI PXI-6220 board for SCXI module measuring channels, a high-performance Ethernet controller for the distributed I / O system and industrial control cFP-2110 running operating systems hard real-time, multi-channel vibration measurement complex K-5101.
-
ViTec Co. Ltd
The hardware part of the measuring system of the test bench is built on the basis of equipment from National Instruments and contains the following components: multichannel switching system for SCXI signal conditioning, interrogation system of "fast-changing" voltage signals and AC power PXI, including M-series NI PXI-6220 board for SCXI module measuring channels, a high-performance Ethernet controller for the distributed I / O system and industrial control cFP-2110 running operating systems hard real-time, multi-channel vibration measurement complex K-5101.
-
90-200-001 -
Pickering Interfaces Ltd.
Each power outlet can be programmed to switched on in sequence with a specific timing delay. The delay can be staggered to ensure that order dependent systems - like PXI - can be switched on and off in an orderly way with just one operation. A staggered start up also limits the inrush current associated with the powering up of equipment, including earth current inrush, placing less stress on cabling and leakage breakers. Power on or off instructions can be initiated from either the front panel switch or via the serial interface.
-
Copernicus Technology Ltd
Copernicus Technology supply test hardware accessories to support Intermittent Fault Detection testing using VIFD™ and IFDIS™ test equipment, such as Interface Test Adapters (ITA). We also supply and repair general purpose and customer-spec test hardware accessories: ITAs, Break-Out Boxes (shown below) and Mobile Vibration Systems. The Mobile Vibration System can be quickly set up in repair bays for applying environmental stimulus to components and wiring harnesses during testing.
-
ALVI Technologies
Fullcheck automatically checks the device functions during power-on.Possible to document the operablility and the regular maintenance and calibration of the meterSensoface monitors the sensor and the measuring equipment and provides information on sensor selection and hanglingUnknown cell constants can easily be determined with a standard calibrationEMC design protects the meter from electromagnetic interference ensuring reliable measurement results even under unfavorable conditions.Measuring input is automatically switched over to the appropriate operating mode.Via the standard RS 232 interface your data can be immediately processed by a computer.DatasheetRelated Products