Showing results: 271 - 285 of 3654 items found.
-
PD-Analyser -
Scope T&M Pvt, Ltd.
This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.
-
IBEKO Power AB
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.
-
Dongguan Amade Instruments Technology Co., Ltd
Packaging testing equipment are intended to measure the resistance of corrugated containers to various crushes and burst at given conditions, applied to bursting strength test, ring crush test, edge crush test, flat crush test, pin adhesion test, puncture strength test, bending stiffness test, corrugating medium test, compression test, damp-proof test etc. As corrugated boxes assume the important responsibility of loading and protecting goods playing an inevitable role in modern logistics, so the properties of corrugated boards have to be mastered by manufacturers and users prior to use. The physical performances which are measured by a series of testings are core factors for judging the quality of packaging boxes. Paper testing items mainly include quantification, thickness measurement, whiteness, smoothness,breaking elongation, burst resistance, folding resistance, stiffness, tearability, degree of sizing, etc.
-
yieldWerx Semiconductor
Commonality Analysis (CA) refers to a set of statistical techniques to identify any systematic causes of yield loss. These techniques typically use association rules and/or ANOVA (Analysis of Variance) to identify manufacturing variables that are common to failed devices. Engineers use these techniques to narrow down the possible cause. This information helps in the decision
-
EMCTEST
Our AFJ FFT 3100 & 3300 EMI Receivers cover the full frequency range from 9kHz to 3GHz.To allow a greater flexibility GTemCell can provide either a single or multiple solution of receivers to cover the most common standards and regulations such as CISPR, EN, IEC, FCC etc.
-
Datrend Systems Inc.
Setting a new performance standard in Fetal/Maternal simulationTwo direct Fetal ECG'sFive full Maternal ECG leadsFour separate Fetal ECG tracingsThree Fetal ultrasound channels with "Triplets" capabilityThirteen Fetal static ECG ratesFifteen trends of Fetal data representing real-life case studies
-
HEM -
TOEI INDUSTRY CO, LTD.
The physical quantity of Hall Coefficient, Hall Mobility and Carrier Density etc. can be investigated by measuring at room temperature voltage occurred perpendicularly to the both magnetic field and constant-current when flowing constant-current perpendicularly to magnetic field from current source while applying magnetic field to sample set at the center of magnetic field of magnet.
-
AMIC-5010 -
Amperis sl
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits
-
Specialty Coating Systems
For manufacturers driven to deliver quality products, SCS Ionic Contamination Test Systems are the industry standard, delivering accuracy and performance in a range of configurations.
-
-
MFAGE Family -
Sun Test Systems Ltd.
The MFAGE® is the product name for a variety of mobile multi-function ground support vehicles suitable for all helicopters and a range of fixed wing aircraft.
-
Soken Electric Co. Ltd
Different from a conventional partial dischargemeasuring set provided with a fixed testingfrequency, Model DAC-PD-5 is newly designed toselect the center and the bandwidth of testingfrequencies so that partial discharges emitting in anoptional frequency in the range of a specifiedbandwidth can be detected. Generally, partialdischarges are measured in a wide band frequencythough; the detecting sensitivity must be lowered inorder to detect partial discharges partially.DAC-PD-5 has a wider bandwidth and can measurepartial discharges in a high sensitivity by bypassingnoises emitting bands.
-
Hanco International
Hanco units provide a full high voltage electrical test as required by OSHA. Front-loading, top-loading and portable units are available.- Sticks can be tested wet or dry.- Test units are available to test sticks up to 14 or 21 feet maximum length or up to 8 feet for the portable unit.
-
Multi-Tech Industries, Inc.
Multi-Tech Industries also manufacturers a line of quality instrument-grade electromechanical switches for commercial, industrial, military, institutional and OEM applications. Rotary switches (open frame, enclosed frame), thumbwheel, keyreader and other types are available to be integrated into your process controls or test instrumentation. Standard and custom switch designs can be modified to meet specific customer requirements.
-
AK-30 -
Amperis sl
AC voltage source with 4 channels, current source and aux with 6 channels. DC source can be used simultaneously. Amplitude, frequency and phase angle can be adjusted respectively, independently and continuously; Control via PC via Ethernet RJ45 interface