Filter Results By:

Products

Applications

Manufacturers

Showing results: 676 - 690 of 714 items found.

  • Premium Automotive DMM

    597 - Electronic Specialties Inc.

    *CATIII 1000 Volt / CATIV 600 Volt Approved & Safety Rated *Safe For Use on Hybrids and EV's *Highest Quality Auto-Ranging DMM Designed for Automotive Trouble Shooting *18 Test Functions, 48 Test Ranges *Peak Min/Max records transient voltages as fast as 1 millisecond *Min/Max Mode records variations in all functions *Also measures Temperature via Temp Probe in Both F and C *Milliseconds Pulse Width Measures Fuel Injector ON-TIME *Inductive RPM Readings for both DIS and Conventional Ignitions *Desirable 20 Amp Test Range - Dual Fuse Protection *Modern Design, the Protective Holster is Built Into the Housing *Data Hold, Auto Power-Off, + Trigger Adjust *Large LCD Display w/White LED Backlighting and 40 Segment Analog Bargraph *Blow Mold Case, Test Leads, K-Type Temp Probe, Inductive RPM Clamp and Instructions included *Waterproof to IP67 Standards

  • Premium Automotive DMM

    597IR - Electronic Specialties Inc.

    *Highest Quality Auto-Ranging DMM Designed for Automotive Trouble Shooting *18 Test Functions, 48 Test Ranges *Peak Min/Max records transient voltages as fast as 1 millisecond *Min/Max Mode records variations in all functions *Exclusive Non-Contact IR Thermometer Adapter Included - 1022F/550C max temp readings *Also measures Temperature via Temp Probe in Both F and C *Milliseconds Pulse Width Measures Fuel Injector ON-TIME *Inductive RPM Readings for both DIS and Conventional Ignitions *Desirable 20 Amp Test Range - Dual Fuse Protection *Modern Design, the Protective Holster is Built Into the Housing *Data Hold, Auto Power-Off, + Trigger Adjust *Large LCD Display w/White LED Backlighting and 40 Segment Analog Bargraph *Blow Mold Case, Test Leads, IR Thermometer Adapter, K-Type Temp Probe, Inductive RPM Clamp and Instructions included

  • AC Power Sources

    CSW Series - AMETEK Programmable Power, Inc.

    The CSW Series represents a new generation of AC/DC power sources that address the increasing demands on test equipment to perform additional functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the Compact CSW Series is capable of handling complex applications that have traditionally required multiple systems. The sleek integrated approach of the CSW avoids cable clutter that is commonly found in test systems. All connections are made internally and the need for digital multimeters, power harmonics analyzers, and current shunts or clamps is eliminated.

  • Back Plane Tester

    Alpha Automation Inc.

    This machine is used to test back planes used in telecommunications central stations. An operator loads a completed point to point wired back plane onto a retractable shelf on the front of the tester. Table continues and the disk falls through a hole into the bin. The shelf is pushed back into the machine where it is held in place by pneumatic operated clamps. Then a series of pneumatic cylinders sequentially insert a test card into each location in the back plane. A remote instrument performs a complete point to point continuity, short and hi pot test on all connections in the back plane.

  • AC Line Splitter

    Extech 480172 - Extech Instruments Corporation

    This Extech 480172 Line Splitter provides a fast and easy way to “open” standard 120 Volt AC electrical lines, eliminating the need to cut off the plug and separate the conductors. When connected between a 120 Volt AC outlet and a device under test, this splitter separates the hot/live conductor from the neutral and ground, which enables users to measure AC current up to 15 Amp on a two-wire or three-wire lines using a clamp meter. This splitter also features two Voltage Test jacks so that voltage can be measured using a multimeter.

  • Electrostatic Chuck Optimizer

    Model 640 - TREK, INC.

    Trek’s Model 640 Electrostatic Chuck Optimizer system is a diagnostic tool which enables evaluation and optimization of waveforms/voltages for electrostatic chucks/clamps in order to minimize de-clamp time, maximize clamp force, and achieve optimum wafer processing for ESC systems. Model 640 combines two amplifiers (for two-phase voltage combinations) and a waveform generator, which can be independently programmed and configured to investigate, research, and discover the perfect power supply and waveform recipe to efficiently drive an ESC application. An electrostatic voltmeter (ESVM) is included to monitor residual voltage from the clamping/de-clamping process.

  • Test Leads

    AL-34WB 10A - Standard Electric Works Co., Ltd

    ● Wire length: 1m approx.    Silicone insulated wire (700mm) with wire connected to straight input plugs (150mm PVC wire), and wire for clamp (150mm PVC wire).● Outside diameter of silicone insulated wire: 6.4mm   Outside diameter of PVC wire: 4mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 10A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Test Leads

    AL-34WB - Standard Electric Works Co., Ltd

    ● Wire length: 1.2m approx.    Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm   Outside diameter of  PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Portable Electricity Meter Testers

    EE-120A-1S - EMSYST Ltd

    The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.

  • DM 150-Watt Transmitter

    Loc-150Tx - Vivax-Metrotech Corp

    The Loc-150Tx, 150-Watt DM Transmitter is used primarily with the Defect Mapper (DM) Receiver, however it is also useful for those needing a low frequency, high output transmitter. Typically, the Loc-150Tx, transmitter (DM transmitter) is used to apply a signal current to the anode bed. The pipeline returns the signal via coating faults back to the transmitter. The Loc-150Tx transmitter is designed to be powered from CP (Cathodic Protection) stations, AC or external batteries, eliminating the need for internal batteries. This transmitter has a direct connection mode to apply the locate frequency onto the conductor.  There is no clamp or induction mode.

  • Multiphoton Laser Scanning Microscope

    FVMPE-RS - Olympus Corp.

    The Olympus FVMPE-RS multiphoton imaging system is purpose-built for deep imaging in biological tissue, aimed at revealing both detail and dynamics. Innovative features for efficient delivery and detection of photons in scattering media enable high signal-to-noise ratio acquisition. This translates to bright images with precise details — even from deep within the specimen. High sensitivity is matched with high-speed imaging to capture rapid in vivo responses. For advanced applications, dual-wavelength excitation extending to 1300 nm is available. Independent control of visible or multiphoton laser light stimulation and the ability to synchronize with patch clamp data are also possible.

  • ELECTRICAL TEST Kit

    1021 TK - Standard Electric Works Co., Ltd

    2950 CL ● Pocket size.● 4000 counts.● Full automatic measurement : Voltage measurement. Current measurement. Resistor measurement.● Data hold function.● Continuity check.● Diode measurement.● Select function.● Low battery indication.● Auto off function.● Flashlight (auto off in 1 minute). ALS-2 ● Use with any clamp meter.● x10 mode allows for more accurate measurements of low amperage devices.● x1 mode allows for direct reading.● 4mm voltmeter input jacks.● Integrated ground conductor.● 10 amp capacity.● 10cm plug cord for greater flexibility.

  • Portable Electricity Meter Testers

    EE-120A-3S - EMSYST Ltd

    The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.

  • RF Conducted Immunity Test System

    RFCI61000-4-6 - Lisun Electronics Inc.

    RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.

  • True RMS AC Voltage/Current Datalogger

    Extech DL150 - Extech Instruments Corporation

    The DL150 is a True RMS AC voltage and current data logger. Data log up to 100,000 readings of TRMS AC Voltage (600) or Current (200 Amp) with a user programmable sample rate from 1 second to 24 hours. LCD displays time/date, current reading, min/max, and if the user settable high/low alarms have been exceeded. Readings can be downloaded to your PC via the USB interface. Featuring Normal, Peak, and Capture (user specified trigger level) recording modes. Complete with current clamp, test leads, alligator clips, software, USB cable, 110-Volt AC Adapter, and four (4) AAA batteries.

Get Help