Showing results: 76 - 90 of 98 items found.
-
National Technical Systems
Contamination Analysis, which begins with a set of basic evaluations that on most occasions will answer the “What is this?” question. The protocol contains four parts:*Visual Examination*Organic Analytical Testing by Fourier Transform Infrared (FTIR) Spectroscopy*Elemental Analytical Testing by Scanning Electron Microscopy / Energy Dispersive X-Ray Spectroscopy (SEM/EDS)*Ionic Analytical Testing by Ion Chromatography (IC)
-
ALS Co., Ltd
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
Nexera Organic Acid Analysis System -
Shimadzu Corp.
The Nexera Organic Acid Analysis System has been well-received in the fields of food and environment as a highly selective high-sensitivity system. It uses separation by ion exclusion chromatography and Shimadzu’s unique detection technique (pH-buffered electric conductivity detection). Recently, this system is being utilized by even more users in a wide variety of fields, and its usage in the fields of pharmaceuticals and life science is increasing.
-
Thermo Fisher Scientific Inc.
We offer a full spectrum of analytical technologies, and sample clean up and moisture extraction reagents, designed to provide reliable, accurate, and precise results that make compliance easier and help you reduce regulatory risks. Organic Elemental Analysis, Trace Elemental Analysis, X-Ray Fluorescence (XRF) Spectrometry, Automated Discrete Photometry, Gas Chromatography Mass Spectrometry (GC-MS), Accelerated Solvent Extraction (ASE).
-
Model N901 -
Teledyne Advanced Pollution Instrumentation
The Model N901 is a near-continuous hydrocarbon gas analyzer that measures the concentration of Methane (CH4) and Total Hydrocarbons (THC) in air. The concentration of the non-Methane (NMHC) component is calculated by the subtraction of CH4 from THC, with high sensitivity and accuracy. The hydrocarbons are measured using a Flame Ionization Detector (FID), in combination with gas chromatography (GC). The instruments range and performance are tuned specifically for use in ambient air quality monitoring assessments.
-
ASX‑280 -
Teledyne LABS
Users call CETAC Autosamplers the best on the market, and it’s easy to see why. Put the most reliable, efficient and solidly built autosampler to work in your lab for sample analyses. We have a model to meet your needs, regardless the size of your lab or your specific technique, whether AA, ICP, ICP-MS, TOC, US-VIS, flash/prep chromatography, protein purification, liquid handling or others.
-
ASX‑560 -
Teledyne LABS
Users call CETAC Autosamplers the best on the market, and it’s easy to see why. Put the most reliable, efficient and solidly built autosampler to work in your lab for sample analyses. We have a model to meet your needs, regardless the size of your lab or your specific technique, whether AA, ICP, ICP-MS, TOC, US-VIS, flash/prep chromatography, protein purification, liquid handling or others.
-
ReaXus LD Class -
Teledyne LABS
The versatile LD Class consists of dual-headed, positive displacement piston pumps, delivering unmatched performance for analytical, flash, and small-scale preparative chromatography applications.The pumps are designed for high flow rate accuracy and low pulsation required for Analytical Liquid Chromatography (HPLC). Standard fluid path materials are Stainless Steel, PEEK, in addition to optional Hastelloy. Other available features include jacketed heads for temperature controlled processes. With 12 mL/min, 36 mL/min, and 100 mL/min versions, reaching pressures up to 6,000 psi, these pumps will meet the performance requirements of demanding HPLC needs.The high performance linear cams, along with automatic pressure compensation, provide precise flow rates for very accurate high pressure and low pressure gradients. Standard features include an integrated Prime-Purge Valve, Pulse Dampener, interactive keypad control, and complete PC control status through RS-232 and Micro USB 2.0 ports. The LD Class provides the precise flow and low pulsation for the most challenging separations.
-
UF-Amino Station -
Shimadzu Corp.
Two major problems exist with traditional amino acid analysis techniques. The first technique (ion-exchange chromatography with postcolumn derivatization) allows many components to be analyzed at once but the method run times are long. The second technique (reverse-phase HPLC with pre-column derivatization) enables faster analysis but the number of analyzed components is limited. As a result, chemists are forced to make a decision to either analyze a large number of components or have a fast method.
-
AMS Technologies AG
AMS Technologies has a long track record of developing and manufacturing customized optical technologies solutions – tailored to the requirements of applications like: *Life Sciences *Biomedical Photoacoustic Imaging; Photoacoustic Microscopy, *Mesoscopy, Macroscopy *MALDI Mass Spectrometry (Matrix Assisted Laser Desorption Ionisation) *Fluorescence Lifetime Imaging (FLIM) *Pumping of Dye Lasers, OPOs, Raman Lasers *LIDAR *Gas Chromatography *Interferometry *Sensing *Micromachining *Marking *And Many More…
-
Haomai Electric Power Automation Co.,Ltd.
The laser-based photoacoustic spectroscopy transformer oil and gas online monitoring system developed has a lot of advantages comparing with the traditional oil chromatography oil and gas online monitoring equipment and wide light source photoacoustic spectroscopy transformer oil and gas monitoring system. Please check the following figure to see the details:
-
ALS Co., Ltd
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
VUV Analytics, Inc.
All gas phase molecules absorb strongly in the vacuum ultraviolet region (120 – 240 nm), yet application of VUV absorption technology to routine analytical detection and measurement has not been addressed…until now. The VGA-100 is the world’s first benchtop VUV spectrometer. It is a universal mass-sensitive gas chromatography detector that provides both qualitative and quantitative data. The strong absorption of gas phase molecules in the VUV spectrum provide excellent sensitivity, and the compound-specific absorption spectra provide unparalleled selectivity.
-
ACQUITY QDa -
Waters Corporation
ACQUITY QDa is as intuitive as an optical detector, with the robustness to handle all of your analyses. Working in harmony with your chromatography, it is pre-optimized to work with your samples, without the sample-specific or user adjustments typical of traditional mass spectrometers. For the first time, any analytical scientist can consistently generate the highest quality mass spectral data, routinely without the need for any special training or expertise thus eliminating any need to contract out and wait for results from specialist analytical service laboratories.
-
Nexera UC Prep -
Shimadzu Corp.
The Nexera UC Prep is a new preparative supercritical fluid chromatography system that offers both the high basic performance developed for the previous Nexera UC model and original state-of-the-art preparative SFC technologies. It resolves a number of issues in preparative tasks, reducing labor and improving efficiency while fitting into pre-existing workflows. Not only does the Nexera UC Prep achieve superior recovery rates for purification, it provides flexible system configurations in a compact design, requiring low installation space and allowing you to maximize lab resources.