Filter Results By:

Products

Applications

Manufacturers

Showing results: 286 - 300 of 309 items found.

  • Multiple Channel Burn In Power Supply

    MCPS - Test Electronics

    The most important features of this burn in power supply is its ability to hold a constant output for each channel even in the event that a unit under test on one channel may short and fail. Since each channel has it''s own transformer, no glitches or voltage spikes can get into any of the other channels. This image shows the results as the second channel from the left is shorted with a small wire and the circuit breaker pops out. Used for burn-in testing and other timed testing where power isolation is required. Very basic simple circuit, see schematic below. Cleans and frees up benchtops, burn in racks and work space clutter. Available in benchtop or rackmount.

  • Digital High Voltage Insulation Tester - Autoranging Insulation Measurements to 10MOhm

    Extech 380363 - Extech Instruments Corporation

    This Extech insulation tester measures up to 10GΩ with 250V, 500V and 1000V Test Voltages. Features include: Lo-Ohms for testing connections, analog bargraph for viewing trends, AC/DC Voltage measurement to 999V, manual data record/recall function (9 sets), and live circuit display warning and beeper. Can be used to test motor, transformer windings, instruments, and appliances, check for moisture in wire and cable assemblies, safely evaluate a new wiring installation, and check for carbon tracking in breakers, relays, and switches. Extech Insulation Testers offer high sensitivity to assure reliable monitoring of low resistance motor windings. Complete with carrying case, test leads, and 6 x AA batteries.

  • 15 Amp 120 VAC Filter and Surge Arrestor

    AS-AC15 - Array Solutions

    - 15 amp 120VAC quad outlet for high power devices- Resettable circuit breaker protection, easy to use and reset- I EA standard input plug and #14 GA AC line cord for USA - standard interface- MOV surge arrestors included - for even more protection- High level of common mode and differential mode filtering digital noise and RF filtering eliminates- digital artifacts and RF interference - See chart- Front Panel Neon Blue AC ON indicator - just plain cool to look at, not too bright!- Double shielded box inside - for optimum filtering operation- Size 6W X 4H X 4 3/4 D in inches approx 3 lbs

  • 3-Phase AC Voltage Transducer

    ENVIROMUX-PT3-600 - Network Technologies Inc

    Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.

  • AC / DC Electronic Loads – Benchtop Testing to Automated Test Systems

    Chroma Systems Solutions, Inc.

    Chroma is the global leader in Electronic Load manufacturing. Chroma’s AC Electronic Loads are designed for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources, and other power devices such as switches, circuit breakers, fuses and connectors. Chroma’s DC Electronic Loads are used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, and fuel cell testing. Chroma loads can do it all including full current down to 0.4VDC, CZ mode, user defined waveforms, timing measurements, and 3 current ranges per load. Chroma’s electronic loads come standard with either USB or RS232 ports for control and can be configured for GPIB (IEEE-488) control as well.

  • Precision Capacitance and Dissipation Bridge

    SG2008 - Shanghai Jiuzhi Electric Co., Ltd.

    SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (tgδ) and capacitance (C) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test such asHigh Voltage (EHV) class Bushings, Windings of transformer (1/2/3 windings), shunt reactors, Current Transformer, Capacitor Voltage transformer(CVT), grading capacitors of Circuit Breakers, Surge Arrester and other electrical equipments. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

  • Microohmmeter

    MMR-6500 - Sonel S.A.

    The MMR-6500 digital meter is designed for measuring low resistances with a stabilised current of up to 100 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6500 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.

  • Microohmmeter

    MMR-6700 - Sonel S.A.

    The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

  • Micro-Ohmmeters

    IBEKO Power AB

    Contact resistance measurement is one of the most important and common tests during switchgear manufacturing, commissioning and maintenance stages. Besides switchgear testing, the RMO digital micro-ohmmeters are designed for simple, safe and efficient testing of:disconnecting switches,high-current bus bar joints,cable splices,welding joints,and different high-current links in factory and high-induction field environments.All DV Power RMO micro-ohmmeters use Kelvin’s 4-point measurement principle which is the most convenient for very small resistance measurements. The measurements are accurate and in accordance with international standards for AC high-voltage circuit breakers testing (IEEE C37.09 and IEC 62271-100).Starting from 2003, DV Power has been a trend-setter on the market when our first 500 A micro-ohmmeter weighing only 8 kg (RMO500A / CPM500) was released.Currently, DV Power products portfolio includes 16 models, divided into 3 series:13 portable models: RMO-A (6) and RMO-G (7) series.6 handheld models: RMO-H (6) seriesThe instruments generate a user-selectable and ripple-free test current up to 800 A in an automatically regulated test ramp. Test current ramping significantly decreases the influence of the magnetic transients to measurement.

  • Protective Bonding Testers

    RMO-E Series - IBEKO Power AB

    The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E

  • Ground Grid Tester

    GGT Series - IBEKO Power AB

    The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

Get Help