  • LC/MS/MS Method Package For Short Chain Fatty Acids

    Shimadzu Corp.

    Of the short-chain fatty acids produced by intestinal bacteria, acetic acid, propionic acid, and butyric acid are well known, and it has been reported that there are some connections between them and lifestyle-related diseases such as obesity and diabetes. Generally speaking, short-chain fatty acids are highly volatile and highly hydrophilic. This makes it dificult to perform LCMS analysis using a conventional reverse phase system. For that reason, this method package targets short-chain fatty acids (C2 to C5) that have been derivatized using 3-nitrophenylhydrazine (3-NPH). Through making settings for MRM transitions, it can be used for the simultaneous analysis (of 22 components), including organic acids related to the central metabolic pathways.

  • Inductively Coupled Plasma Mass Spectrometer

    ICPMS-2030 - Shimadzu Corp.

    With its newly developed collision cell and optimized internal structure, the ICPMS-2030 provides superior sensitivity. At the same time, thanks to the adoption of its proprietary mini-torch unit and provision of an Eco mode, the quantity of argon gas needed for analyses has been greatly reduced to the industry's lowest levels. As a result, low running costs are assured. The Development Assistant function of the software automatically sets the optimal analysis conditions for quantitative analysis. Then, after measurements are complete, the Diagnosis Assistant function automatically checks the validity of the necessary data. While reducing the burden on the user, the efficiency of analyses is enhanced and the reliability of the data can be increased. It complies with FDA 21 CFR Part 11.

  • Advanced Customization Environment Development and Runtime Package

    B4606A - Keysight Technologies

    Dramatically reduce your time to insight with the Keysight B4606A advanced customization environment for logic analyzers. Quickly sift through large amounts of data during your digital system validation. With this optional development and runtime package, you can customize your logic analyzer's data analysis and displays as well as create scripts and interactive dialogs to automate repetitive tasks. The seamless integration of Microsoft's Visual Basic for Applications (VBA) into the logic analyzer application makes this possible. The package is available for the U4154A AXIe-based logic analyzer module, 1680 Series standalone logic analyzers, 1690 Series PC-hosted logic analyzers, and the 16900 Series modular logic analysis systems.

  • Colorimetry, Turbidity & UV-Vis Spectrophotometry

    Thermo Fisher Scientific Inc.

    Colorimetry, turbidity, and spectrophotometry meters for water analysis. You can choose from 134 preprogrammed methods to measure the concentrations of sample components with our colorimetry meters. These portable meters can go with you anywhere to test drinking water or wastewater. Take your portable turbidity meter to the source for on-site measuring. Our turbidity meters feature white and infrared light sources allowing you to meet regulatory methods. Achieve simple and efficient water and wastewater analysis with our UV-Vis and Vis spectrophotometers. These meters include over 260 preprogrammed methods using common reagent chemistries, making them the ideal instruments to include in your laboratory.

  • Design for Test Service

    Testing House, Inc.

    Design For Test (DFT) is a technique used to implement certain testability features into a product. Testing House can provide an analysis of the CAD data for testability of your circuit board. Access to a board can be very difficult as boards get smaller and designs get more densely populated. We can work with your design engineer to improve testability and maintain an effective in-circuit test. When access to the board is limited and boundary scan devices are present, we can provide the customer a list of key nodes that will require access in order to provide a very effective test. Our analysis will provide a list of all the accessible test points and an explanation for any nodes declared inaccessible.

  • Digestion Systems

    Tecator line - FOSS A/S

    FOSS Tecator line Digestion systems are based on a digestion unit and a tube rack, allowing fully automated digestion for convenient, safe and flexible Kjeldahl analysis. Two way PC communication supports traceability and GLP. These versatile digestion systems are capable of handling eight, twenty or forty tubes in volumes of 100 ml, 250 ml or 400 ml dependent on chosen configuration. Parameters: Kjeldahl digestions, Chemical Oxygen Demand & other reflux chemistries, Trace metal analysis by AAS or ICP instruments. Sample types: Raw materials and finished products in Food, Feed, Agriculture and related matrices, Water & Wastewater and a wide range of industrial compounds.

  • Field Strength Meter

    SMP2 - Wavecontrol, S.L.

    2-in-1: broadband measurements (1 Hz - 18 GHz) and spectrum analysis (1 Hz – 400 kHz)Real-time FFT-based spectrum analysis using digital processing.Weighted Peak Method (WPM) for automatic and real time comparison with limits.Special auto-gain function for peak detection (indispensable for procedures such as welding).Display of results in RMS and peak values.Function for time domain measurement of a specific frequency.Automatic field probe recognition.E&H field selection.Total field value and value for each component (X, Y, Z).Frequency SPAN selection.High Pass Filters at 1 Hz, 10 Hz, 25 Hz and 100 Hz.Max-hold function.Display of maximum, minimum and average

  • Machinery Fault Simulator

    MFS - SpectraQuest, Inc.

    To gain an in-depth understanding of different vibration signatures, controlled experiments on a device that emulates real world machinery are needed. While analysis of a single machinery fault may be beneficial, there are many occasions when the analysis of the interaction between dynamic stiffness, resonance, and speed is essential in order to gain an understanding of real world vibration spectra. With the MFS, the expertise required to diagnose industrial machinery problems in well controlled experiments can be developed and enhanced. With a plant running at full production, it is virtually impractical to gain an understanding of the kinetics and dynamics of machinery without adversely affecting production and profits: The MFS enables offline training and experimentation which in turn will minimize production downtime.

  • Machinery Fault Simulator – Lite

    MFS-LT - SpectraQuest, Inc.

    To gain an in-depth understanding of different vibration signatures, controlled experiments on a device that emulates real world machinery are needed. While analysis of a single machinery fault may be beneficial, there are many occasions when the analysis of the interaction between dynamic stiffness, resonance, and speed is essential in order to gain an understanding of real world vibration spectra. With the MFS, the expertise required to diagnose industrial machinery problems in well controlled experiments can be developed and enhanced. With a plant running at full production, it is virtually impractical to gain an understanding of the kinetics and dynamics of machinery without adversely affecting production and profits: The MFS-LT enables offline training and experimentation which in turn will minimize production downtime.

  • Universal Offline AXI Systems

    XT-series - Matrix Technologies GmbH

    The XT-series provides the advanced inspection capability of Nordson MATRIX‘s inline system in a smaller footprint manual load/island of automation system. The platforms are designed for flexibility and ease of use for a wide variety of products requiring 2D and 2.5D automated X-ray inspection. The XT-6/XT-6A platform is a highly flexible automated X-ray inspection system with minimum footprint and a parallel-kinematic Hexaglide manipulation unit for extreme-angle off-axis image acquisition with high resolution. It is suitable for high-quality X-ray analysis of electronic assemblies and material analysis of parts that require flexible part manipulation with multiple inspection angles. For batch modes and volume inspection the XT-6 can be equipped with a single-sided conveyor setup and magazine load/unload station (XT-6A).

  • PXI Oscilloscope

    PXI-5922 / 779153-03 - NI

    24-Bit, Flexible Resolution PXI Oscilloscope—The PXI‑5922 high-resolution oscilloscope features a flexible measurement resolution range up to 24 bits, with up to 114 dBc spurious‑free dynamic range (SFDR), and up to 15 MS/s rates. This PXI oscilloscope has flexible settings for coupling and voltage range, as well as a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. The PXI‑5922 is capable of taking extremely resolute and accurate analog measurements. It is ideal for audio signals, spectrum analysis, and other small, accurate signal measurements. The PXI‑5922 also features PXI synchronization and data streaming capabilities.

  • PXI Oscilloscope

    PXI-5922 / 779153-01 - NI

    24-Bit, Flexible Resolution PXI Oscilloscope—The PXI‑5922 high-resolution oscilloscope features a flexible measurement resolution range up to 24 bits, with up to 114 dBc spurious‑free dynamic range (SFDR), and up to 15 MS/s rates. This PXI oscilloscope has flexible settings for coupling and voltage range, as well as a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. The PXI‑5922 is capable of taking extremely resolute and accurate analog measurements. It is ideal for audio signals, spectrum analysis, and other small, accurate signal measurements. The PXI‑5922 also features PXI synchronization and data streaming capabilities.

  • Rotor Winding Monitoring

    Iris Power

    The most common causes of induction motor failures are due to breaks in rotor bars or shorted circuit rings due to rotor eccentricity. Current Signature Analysis (CSA) is used to accurately measure faults in the induction motor rotors through changes in the rotor magnetic field.

  • Atomic Absorption Spectrophotometer

    AA-7000 - Shimadzu Corp.

    The AA-7000 series of Atomic Absorption Spectrophotometers features high-sensitivity analysis, flexible system configuration, and a compact footprint for user-friendly operation. In addition, the AA-7000 systems are the first AAs to employ a vibration sensor as standard. The AA-7000 series ensures efficient and comfortable operation in your laboratory.

  • Vibration Test Analyzer

    VAS-HJ - Beijing Pansino Solutions Technology Co., Ltd.

    The VAS-HJ vibration test analyzer is mainly used for the collection, analysis and storage of the vibration signals of the gas turbine engine rotor. The system can not only measure and analyze local signals, but also connect it to the customer data terminal through a network cable to complete remote testing.