Filter Results By:

Products

Applications

Manufacturers

Actuators

Converts a signal to an action.


Showing results: 196 - 210 of 228 items found.

  • MEMS Module

    COMSOL, Inc.

    The design and modeling of microelectromechanical systems (MEMS) is a unique engineering discipline. At small length scales, the design of resonators, gyroscopes, accelerometers, and actuators must consider the effects of several physical phenomena in their operation. Consequently, COMSOL Multiphysics is ideally suited for MEMS applications. To this end, the MEMS Module provides predefined user interfaces with associated modeling tools, referred to as physics interfaces, for a variety of coupled physics, including electromagnetic-structure, thermal-structure, or fluid-structure interactions. You can include a variety of damping phenomena in your model: thin-film gas damping, anisotropic loss-factors for solid and piezo materials, anchor damping, and thermoelastic damping. For elastic vibrations and waves, perfectly matched layers (PMLs) provide state-of-the-art absorption of outgoing elastic energy.

  • PXIe-6509, 96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module

    787358-01 - NI

    PXIe, 96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module - The PXIe-6509 can directly drive external digital devices such as solid-state relays (SSRs). You can configure each line for input or output and you also can configure each line with a user-configurable pull-up or pull-down resistor. Using the PXIe-6509 programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. The PXIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter.

  • FADEC/EEC Test Platform

    Bloomy Controls, Inc.

    The FADEC/EEC Test Platform provides a hardware in-the-loop (HIL) closed-loop test environment for dynamic and maintenance testing of full-authority digital engine control (FADEC) and electronic engine control (EEC) units of both rotary- and fixed-wing airframes. The system simulates one or more turbofan engines, including its sensors and actuators for use with the most sophisticated FADECs and EECs on the market. The system delivers repeatable, cost-effective testing in a fraction of the time needed with typical in-house simulation test systems.

  • Solution for High Density I/O Applications

    BitBox - BitFlow, Inc.

    The BitBox is BitFlow''s new solution for high density I/O applications. Many machine makers require a large number of computer managed I/O signals for continuous control of the system state. This means controlling devices such strobes, solenoids, actuators, indicators etc. as well as gathering inputs from photo-detectors, switches, encoders and triggers. In general, BitFlow frame grabbers come with a fairly large number of inputs and outputs, but for some system this is simply not enough. Most customers end up purchasing another device to manage the I/O, which adds expense, requires another slot, another driver and SDK, another manual, etc. The BitBox has been designed for just this situation. It is controlled completely from the frame grabber, uses the same API, driver and manuals as the frame grabber. This saves time, money, space, and learning curve.

  • Precise Testing & Simulation of A2B® Networks

    A2B®-Component-Tester - NOFFZ Computer Technik GmbH

    The Automotive Audio Bus (A²B®) is a bus developed by Analog Devices Inc. for infotainment systems in automobiles. It is increasingly being used in other applications such as AV conferencing systems. Typical A²B® -products are Hi-Fi amplifiers/speakers, head units, eCall systems, microphones, vibration/noise suppression units, actuators, or sensorsCommunication happens via a simple two-wire UTP (Unshielded Twist Pair) cable. All A²B® -components are connected in a master/slave architecture to form a network. The complexity of audio systems in these A²B® -networks is reduced, and with it the cost and weight.

  • Isolated Digital I/O 60VDC, 150mA

    OTP2 module no.186 - LXinstruments GmbH

    The National Instruments PXI-6528, PCI-6528, and PXI-6529 Digital I/O Modules are isolated digital I/O interfaces for PCI and PXI. These modules can use inputs from NI 6528 and PXI 6529 devices to capture the status of sensors, actuators, and logic devices. NI 6528 devices have 24 SSR outputs for switching external devices with input currents up to 150 mA. The NI 6528 and PXI-6529 devices are suitable for a variety of applications, from automotive development and industrial factory automation to aerospace, laboratory research, and biomedical applications due to their high current handling capacity and isolation.

  • PCI-6517, 32-Channel, ±30 V, Sink Outputs, Bank-Isolated Digital I/O Device

    779083-01 - NI

    The PCI-6517 is an industrial digital output interface, with one bank of channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6517 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6517 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.

  • PCI-6516, 32-Channel, ±30 V, Source Outputs, Bank-Isolated Digital I/O Device

    779082-01 - NI

    The PCI-6516 is an industrial digital output interface, with one bank of channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6516 module is an industrial digital I/O interface, with all channels on an isolated bank. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6516 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.

  • PXI-6528, 48-Channel, 24 Sink/Source Inputs, 24 Sink/Source Outputs, Channel-Channel Isolated, PXI Digital I/O Module

    778543-01 - NI

    48-Channel, 24 Sink/Source Inputs, 24 Sink/Source Outputs, Channel-Channel Isolated, PXI Digital I/O Module—The PXI‑6528 is an industrial, parallel digital I/O interface. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6528 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.

  • Fluids Resistance Testing

    National Technical Systems

    NTS has extensive abilities in fluid testing. We’ve tested a large variety of products, from pipe fittings to process controllers, flexhoses to pressure vessels, valves to actuators, tank liners to heat exchangers, water to Skydrol. We have tested these products for a variety of measurements, from viscosity to flash point and auto ignition, among others. NTS fluids testing facilities are equipped with computerized data acquisition, reduction and analysis equipment for monitoring the functional characteristics of specimens during testing. NTS has considerable expertise in high flow testing of small devices – such as meters, indicators, totalizers, sensors, transmitters, and check valves.

  • PCI-6518, 32-Channel, ±30 V, 16 Sink/Source Inputs, 16 Source Outputs, Bank-Isolated Digital I/O Device

    779084-01 - NI

    The PCI-6518 is an industrial digital I/O interface, with two banks optically isolated channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6518 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6518 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.

  • PCI-6519, 32-Channel, ±30 V, 16 Sink/Source Inputs, 16 Sink Outputs, Bank-Isolated Digital I/O Device

    779085-01 - NI

    The PCI-6519 is an industrial digital I/O interface, with two banks optically isolated channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6519 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6519 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.

  • PCI-6509, 96-Channel, 5 V, TTL/CMOS, 24 mA, PCI Digital I/O Device

    778792-01 - NI

    The PCI-6509 can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is required for outputs. Using programmable power-up … states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the PCI-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.

  • PXI-6514, 64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Source Outputs, Bank-Isolated PXI Digital I/O Module

    778965-01 - NI

    64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Source Outputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6514 is an industrial digital I/O interface with eight banks of isolated channels. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6514 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.

  • PCIe-6509, PCI Express, 96-Channel, 5 V, TTL/CMOS, 24 mA Digital I/O Device

    779976-01 - NI

    The PCIe-6509 can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is required for outputs. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the PCIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.

Get Help