Showing results: 1 - 15 of 17 items found.
-
CSA Series -
Ohm-Labs, Inc.
Ohm-Labs’ CSA series of ac current shunts are designed as laboratory standards for ac current measurement up to high frequencies.
-
Guildline Instruments Ltd
AC Current Shunts feature low uncertainty (high accuracy), low temperature coefficients and excellent stability. These shunts are purely resistive with extremely small values of reactance. The 7340 shunts may be used over a wide frequency range from DC to 100 kHz and are optimized for use with thermal converters.
-
Series A co-axial shunt and Option 02F/B shunt -
Powertek LLC
Use with wattmeters, DMMs and power analyzers to extend current measurement ranges. Use with phase angle meters to enable phase angle measurements between voltage and current. Ultra low phase shift
-
783731-01 -
NI
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Especially to accurately measure large DC currents via shunt resistors, ie for making isolated detection of mV voltage on shunts. Variants with calibrated range selection. Working voltage up to 3600 V AC / DC.
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Measurement of DC or AC voltages up to () 3600 V and of large DC currents to about () 20 kA with shunt resistor or directly in the device to () 5A DC and AC. Variants with calibrated range selection.
-
Teledyne LeCroy
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
DCP-BTA -
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Ajinkya Electronic Systems
Besides from physical parameters; application also demands logging of voltages and currents. The IM2000 series Voltage Logger / Current Logger / Power Logger offered by us can accept DC shunt inputs, signals from convertors 4-20mA range or CT current inputs for higher AC currents or AC signals from PT. These can calculate values from the recorded channels to generate additional channel values.
-
Keysight Technologies
Measure voltage, current and power on 4 channels: DC, 1-phase AC or 3-phase ACMake more accurate power measurements: 0.05% at 50/60 HzMeasure current directly: internal shunts to 50 Arms, or with external probes or transducersAddress multiple test scenarios with isolated inputs
-
Multiple Current Shunt -
Ohm-Labs, Inc.
*IMPROVED ACCURACY*WIDE RANGE: <1 TO 300 A*HIGH IMMUNITY FROM AMBIENT TEMPERATURE CHANGESDC OR AC USE*TRANSPORTABLE*CUSTOM VALUES AVAILABLEWith new features, Ohm-Labs' model MCS Multiple Current Shunt for the first time overcomes much of the chief problem with accurate current measurement.
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation Amplifier for DC voltage and current measurement with galvanic isolation, active and passive standard signal isolation amplifier, supply isolation amplifier for supplying 2-wire sensors, transmitter for temperature and AC signals, isolating amplifiers for high voltages and shunt applications. T
-
Guildline Instruments Ltd
Capacitance Bridge is an instrument employing the AC Current Comparator principle. The 9910A is a versatile instrument for a wide range of applications including capacitance measurements, cable testing, corona loss measurements, insulator and dielectric testing, inductance measurements, potential transformer error measurements, shunt reactor loss measurements and power transformer testing.
-
LS-96 -
Standard Electric Works Co., Ltd
● For ranges higher than 20A DC, use external shunt with a 50mV DC Ammeter.● For ranges higher than 300V DC, use external Volt Divider with a 1mA Voltmeter.● For ranges higher than 5A AC, use external Current Transformer with a 5A AC Ammeter. ● For ranges higher than 600V AC, use external Potential Transformer with a 150V AC Voltmeter.● Full Scale Deflection : 250° ● Accuracy : Class 1.5● Composition : Glass window, ABS resin frame and case, PC glass fiber base mounting fittings included.● Color : Black base and frame, white scale plate and meter body.● Pointer : Stick shape in black color.
-
DP150/DP200pro -
Powertek LLC
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.