-
product
Voltage Calibrators
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
product
Electronic Calibration Module (ECal), 18 GHz, Type-N, 50 Ohm, 2-port
N4690D
The Keysight N4690D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4690D is a precision 2-port ECal module that supports 50-ohm type-N connectors up to 18 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4690D is included for securing your ECal module and accessories.
-
product
Panel Meter Calibrator
1040C/CU
Calibrate panel meters, transducers, circuit breakers and relay units with Model 1040C, a portable, field-ready unit featuring eight key calibration functions.
-
product
MP field sources calibration set
The MP field source calibration set is used to measure electric or magnetic fields in a frequency range up to 3 GHz. RF fields or transient fields can be measured. The MP field source calibration set is used to check fields of the Langer EMV-Technik GmbH field sources, fields of TEM cells and IC striplines.
-
product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Calibration
RF Test Equipment
We calibrate following types of RF test equipment:EMF test systems (frequency selective)EMF test systems (broadband)Field strength transfer standards (e.g. RefRad)Line Impedance Stabilisation Network (LISN)Cable, attenuator, couplerAntennaField Probe
-
product
Bench Power Supply, Calibrated w/Data, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL D
The 72-2690 CAL D from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
product
AC Calibration Standard
1U647-001
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL DU
The 72-7755 CAL DU from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
product
Very High Temperature Calibration System
BBS-VH
The 'True' Black Body - Range 500 to 1300°C, Resolution 1°C, Accuracy <0.3% reading, Stability ±0.5°C, Aperture Ø 25 mm, Emissivity better than 0.99, Semi-Portable
-
product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
Calibrated, Integral Isolator Noise Sources
Calibrated, Integral Isolator Noise Sources by Pasternack
-
product
Waterproof Infra-Red Turbidimeter (NTU) with calibration kit
TN 100
The microprocessor-based waterproof TN100 meter is an easy-to-use turbidimeter that meets the rigor of rugged field applications. It is a "must -have" for anyone monitoring turbidity on the go. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).
-
product
Refractometer Calibration Oils
Calibration Oils are one of the most commonly used materials for calibrating refractometers as they have good traceability, particularly to NIST. Having a high temperature co-efficient, Calibration Oils are best used where strict temperature control is adopted either by Peltier or external waterbath between 10 and 75 °C as well as with refractometers operating at ambient by making use of supplied tables or an RI/°C Temperature Calculator as long as the prism temperature is reliably known.
-
product
Large Calibre Barrel Bore Gauge System
BG20
Aeronautical & General Instruments Ltd.
The BG20 has been specifically designed to modernise and improve the inspection routines of large calibre barrels. A two-point measuring head is supported in the barrel or chamber by a clear disk which facilitates the angular alignment of the head and the location of a suspected defect.
-
product
Power Calibrators And Power Quality Calibrators
Calmet Smart Calibration Devices
A power calibrator and a power quality calibrator are both specialized instruments used to verify and adjust the accuracy of other instruments, but they focus on different aspects of electrical power.
-
product
Calibrated Diffuse Reflectance Standards
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
product
Energy Meter Calibration
Beijing GFUVE Electronics Co.,Ltd.
The process of verifying the measurement accuracy and working status of the energy meter through the actual test.
-
product
Electrical Calibrators
An electrical calibrator, or dc calibrator from Fluke Calibration includes many innovative and multi-functional solutions to help laboratories operate efficiently, increase throughput, and comply with today’s quality standards. Versatile models and options provide a wide range of possibilities to match a variety of workloads and budgets. Electrical calibrators include: Multi-product calibrators; multifunction calibrators; oscilloscope calibrators; power calibrators; pressure/temperature calibrators.
-
product
Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit
72-1015 CAL DU
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
product
Calibration Measurement
The process of comparing a measuring instrument's readings to a known, more accurate standard to detect and correct errors.
-
product
Relay Test Set and Universal Calibrator
CMC 256plus
The CMC 256plus is the first choice for applications requiring very high accuracy. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibrator.
-
product
Decade Box, Calibrated W/D & U, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL DU
The 72-7270 CAL DU from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Testing And Calibration Services
Radian Research provides a broad range of unrivaled value-added servicesincluding calibration services done by laboratory and on-site, utilitymanagement training, product training and more.
-
product
Probes, Sensors, Measurement Microphones, Calibrators, Accessories
Passive Probes, Active Probes, USB Isolators, Noise & Vibration Sensors & Accessories, Electro-Acoustic Test Accessories
-
product
CableEye Tester Calibration Verification Board | Cable & Harness Tester
CB50
Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently.
-
product
M2730 DIGITAL PORTABLE FLOW CALIBRATOR
M2730 is the new digital portable calibrator of ForTest® M series. Enclosed in a container of anodized aluminium with shatterproof plexiglass front, we find a completely new circuit board and a mass flow meter sensor, for direct measurement of leaks. Coupled to the micrometer nozzle supplied, they are designed to simulate the desired leakage, facilitating the procedure for programming and verification of leak test instruments.
-
product
RF Calibration Kit
SMK-3000
The SMK calibration kits are precision, high power calibration standards that are used to calibrate RF radios, wattmeters, directional couplers and other high-power RF test equipment in the field or metrology lab. Unlike other calibration solutions, the SMK-3000 calibration kits reduce the cost of ownership and provide a much faster time-to-calibration with lab precision and accuracy you’ve come to expect from Bird.
-
product
Transducer Calibration
m+p SensCal
Regular transducer calibration is an essential requirement for maintaining the accuracy, reliability and repeatability of the results obtained from a measurement system. m+p international’s m+p SensCal program provides a quick and simple process for calibrating accelerometers (piezo-electric with charge output or IEPE, piezo-resistive, capacitive) in your laboratory, as well as velocity or displacement transducers.





























