Inertial Measurement Units
combinations of precision gyroscopes, accelerometers, magnetometers, and pressure sensors measuring motion.
See Also: IMU
-
product
Source Measure Units
NGU
Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.
-
product
PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit
782856-02
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
product
DFB Laser Source Module
LaserPXIe 1200 Series
The LaserPXIe 1200 Series is a highly customizable DFB laser source available in a wide range of wavelengths and powers.
-
product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
product
PXI Source Measure Unit
PXI Source Measure Units (SMUs) combine high-precision source and measure capability with features designed to reduce test time and increase flexibility. These features include high channel density for building parallel SMU test systems, deterministic hardware sequencing for minimizing software overhead, and high-speed update and sample rates for quickly changing setpoints and acquiring data. Additionally, the flexible sampling rate and streaming capability of PXI SMUs allows you to use the instrument as a digitizer to capture transient behavior, and the digital control loop gives you the ability to adjust the transient response of the instrument. The ability to change the transient behavior of the SMU, called SourceAdapt, reduces SMU settling time and minimizes overshoot and oscillations, even with highly capacitive loads.
-
product
4- Channel PXI Source Measure Unit (SMU)
GX3104
The GX3104 is a precision 3U PXI module that forces and senses both voltage and current over a range of ±20 V and up to ± 1 A ( channel 1) with channels 2- 4 capable of supplying up to 500 mA. Total available output current from the module is 1A. The four channels are electrically isolated from the PXI power supply and share a common, isolated ground.
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-194A-002-HI
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXIe-4140, 4-Channel Source Measure Unit
781742-01
The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
Source Measure Units (SMUs)
B1511B
The SMUs of B1500A integrate 4-quadrant voltage/current source and measurement capabilities for accurate IV measurement with the range of 0.1 fA - 1 A / 0.5 µV - 200 V. It supports spot, sweep, pulse sampling and QS-CV measurements.
-
product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
product
Digital Source Capture Unit
DIO2
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Autonomous Driving AI Decision Making ECU
ADM-AL30
ADM-AL30 is dedicated to Autonomous Driving Applications. Powered by Intel® 12th Gen Core i9/i7 CPU and the NVIDIA RTX 4000 SFF Ada GPU, this AI computing platform can process huge amounts of data and make crucial decisions for autonomous vehicles. Equipped with 2 x 10G Base-T and 8 x 1G Base-T1 automotive ethernet ports, as well as 8 x CAN FD and 4 x CAN 2.0 interfaces, it seamlessly integrates into any automotive ecosystem. Plus, its ISO 16750-2 and ISO 7637-2 ensure reliability and safety under the most demanding conditions.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
4-Quadrant General-Purpose Source/Measure Unit, ±20 V, ±1 A Or ±6 V, ±3 A, 20 W
N6784A
The Keysight N6784A is a source/measure unit (SMU) designed for general-purpose precision sourcing and measurement. General-purpose applications can span many different industries and many different devices under test (DUTs). The N6784A SMU is a versatile tool designed to tackle many of these general-purpose applications. Its glitch-free operation ensures safe usage with the DUT during output and measurement range changes, even with capacitances of up to 150 µF. Its 4-quadrant operation enables it to act as a bipolar power supply or a bipolar electronic load, for added versatility. When using the N6784A SMU, engineers can be confident that they have an all-around general-purpose tool for their test systems or lab bench.
-
product
64-Ch 1-Bus Fault Insertion
YAV91082
64 channels 1 thread 2A 250V 1 Fault Insertion Buses Switching up 60W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
4x 3U OpenVPX MOSA Remote Interface Unit
SIU34-RIUVARM-01
SIU34-RIUVARM-01 is a Modular Open Systems Approach (MOSA) Remote Interface Unit (RUI) to manage, monitor and control connected I/O, communications, measurement and simulation interfaces through Ethernet commands from a main mission processors. Extremely low power with 2 x 10/100/1000Base-T Ethernet.
-
product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
The 40-205-008 (PXI) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.