Filter Results By:

Products

Applications

Manufacturers

Amplitude

Amplitude Intensity Modulation

See Also: Interference


Showing results: 301 - 315 of 341 items found.

  • HandyScope HS5 + SureConnect: 200 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 20MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-220XMS-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 200 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

  • HandyScope HS5 + SureConnect: 500 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 40MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-540XMS-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 500 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

  • HandyScope HS5: 100 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 10MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-110XM-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 100 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

  • HandyScope HS5 + SureConnect: 100 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 10MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-110XMS-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 100 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

  • HandyScope HS5: 200 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 20MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-220XM-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 200 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

  • HandyScope HS5: 500 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 40MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-540XM-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 500 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

  • HandyScope HS5: 50 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 5MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-055XM-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 50 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

  • Oscilloscopes

    all-sun

    *Screen Display 60mm×80mm Screen 240 Dot×320 Dots*Backlight Adjustable Save 6 Groups Of Waveforms And 10 Groups of parameters*Dual Channel, Bandwidth 20 MHz*The auto set function, continuous fully automatic adjustment of amplitude range and time base.*Waveforms and waveform parameters can be displayed on the screen at the same time. The user can choose parameters (such as RMS, peak to peak, means, frequency, period and so on) according to the needs.*With 100Msa/s real time sampling rate each channel and 20MHz bandwidth. It can reflect the waveform state quickly and factually, catch the fault impulse with the least breadth of 10ns.*Saving and recalling function. It can save six groups of waveform data and ten groups of parameter setups.*High distinguishable crystal display. It can display the details of the waveform distinctly.*With compact, convenient, full functional operating menu.*It can be portable with lighter, smaller, only 0.7kg weight.*Supplied with Ni-battery. It can be used under all kinds of environments constantly.

  • Capacitor Testing

    EMC Partner AG

    The test system includes control of the nominal AC supply via an integrated variac and also the stress impulse that is applied to the capacitors. Impulse amplitudes are programmable up to 8kV which covers all the requirements. X1 capacitors are stressed up to 4kV, X2 and Y4 capacitors up to 2.5kV and Y2 capacitors up to 5kV. Capacitors up to 1F can be tested with the COMP0804CAP and up to 50F when the COMP0804CAP includes also the decoupling elements to prevent the disturbance signal entering the power mains supply. Control is from the EMC PARTNER Operating System (EPOS) interface which allows fast and easy control of the test process.

  • PXI-5650, 1.3 GHz RF Signal Generator

    779670-00 - NI

    The PXI‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • PXIe Audio Analyzer

    M9260A - Keysight Technologies

    M9260A is significantly different from the traditional general purpose PXI digitizer modules which are being used for today's audio measurement. In order to achieve fast test speed and high performance it comes with large one million sample arbitrary waveform buffer and one million sample "limitless" input buffer, as well as super-linear/low noise amplifiers and digital to analog converters. This enables M9260A's ultra-low residual distortion and high amplitude accuracy. M9260A is now an important part of Keysight Radio Test Solution, and may also be easily integrated into any audio related PXI test system with its developer-friendly drivers and commands.

  • PXIe-5650, 1.3 GHz RF Signal Generator

    781215-01 - NI

    The PXIe‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXIe‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • Ultra Narrow Linewidth, CW TI: Sapphire Laser

    SolsTiS - M Squared Lasers

    Award-winning SolsTiS is a next generation continuous-wave Ti:Sapphire laser designed to meet the needs of pioneering scientists looking for high performance, ease of use, system flexibility and reliability. This fully automated, compact system features a completely sealed, alignment-free cavity with hands-free operation, an unprecedented tuning range, unrivalled power, and the ultimate narrow linewidth, low noise output. SolsTiS has options of high power output up to 5W, linewidths <50 kHz and amplitude noise of less than 0.05%. SolsTiS is made to order giving you the ability to specify your linewidth, output power and wavelength range. Fully integrated accessories such as beam pick-off and fiber coupling are available.

  • RF Conducted Immunity Test System

    RFCI61000-4-6 - Lisun Electronics Inc.

    RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.

  • RF Ports Alignment Software

    Rohde & Schwarz GmbH & Co. KG

    With the R&S®RF Ports Alignment software together with the option R&S®SMW-K545, Rohde & Schwarz provides a standard and tailored solution for calibrating amplitude, time and phase of multi-channel SMW setups. The RF Port Alignment automatically collects the gathered correction data for the multi-channel setup using a connected vector network analyzer such as the R&S®ZNA or R&S®ZNB. Thanks to an intuitive graphical user interface the test engineer is guided through the calibration procedure step-by-step in a convenient way. With a calibrated multi-channel setup, tests of advanced systems in wireless communication or of radar receivers can be performed straightforward.

Get Help