Filter Results By:

Products

Applications

Manufacturers

Amplitude

Amplitude Intensity Modulation

See Also: Interference


Showing results: 286 - 300 of 341 items found.

  • FREQUENCY SYNTHESIZERS (Insight FS) FROM 30 TO 1250 GHz

    Insight Product Company

    Insight Product Company introduces a family of new wide band synthesizers of millimeter and submillimeter waves (Insight FS). Insight FS cover frequencies from 30 to 1250 GHz and generate substantial output power. In the millimeter wave range, each synthesizer covers a full waveguide band (Q, U, V, E, W, F, D, G, Y, J). IPWBS provides several options for frequency and amplitude modulation (analog FM/AM modulation, frequency manipulation, pulses modulation).

  • Phase Noise Tester 5MHz to 40GHz

    Model 7340 - Berkeley Nucleonics Corporation

    Broad Frequency Range in a single compact instrument from 5MHz to 40GHz. Measurement offsets from .01Hz to 100MHz. Absolute Phase Noise - High Drift mode (ability to measure modulations, high drifting or unstable DUTs, etc.). AM (Absolute Amplitude Noise) measurements. Pulsed Measurement Capabilities. Transient Mode: measure WB Frequency, NB Frequency, NB Phase, NB Power (WB/NB being Wide Band and Narrow Band). Dual channel low-noise integrated power supplies.

  • CT / PT Analyzer

    CTPTA-504 - UDEYRAJ ELECTRICALS PRIVATE LIMITED

    UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.

  • Phase Noise Analyzer and VCO Tester

    FSWP - Rohde & Schwarz GmbH & Co. KG

    The R&S®FSWP phase noise analyzer and VCO tester features very high sensitivity thanks to extremely low-noise internal sources and cross-correlation. It can measure phase noise and amplitude noise in mere seconds on highly stable sources such as those in radar applications. Additional options such as pulsed signal measurements, residual phase noise (including pulsed) characterization and integrated high‑end signal and spectrum analysis make the R&S®FSWP a unique test instrument.

  • QAM DVB Analyzer

    Wuhan Sunma Technology Co., Ltd.

    QAM Analyzer designed for both installation and maintenance of HFC system. Measure and display main parameters in DVB testing (channel power, MER, BER, Constellation Diagram), signal level on any frequency, amplitude of the carriers singly in the whole system range, and etc. The Analog, QAM and FM channel can be set and tested efficiently; it also supports HUM measurement, C/N measurement, voltmeter function, spectrum analysis and data logging. Also it is easy for user to obtain a report of test data via PC or printer through toolbox software.

  • Power Line Meter

    Alpha Lab, Inc.

    The Line EMI Meter measures electromagnetic interference in a single-phase AC power line. It plugs into a wall outlet (mains socket) and requires no battery. It immediately displays total line noise in millivolts (range 1999 mV, resolution 1 mV) in the frequency range 10 KHz 10 MHz (the frequency limits at which sensitivity is of the maximum sensitivity). A speaker plays the sound of the EMI, amplitude demodulated, in order to identify the EMI source (such as an AM or shortwave radio station vs. a motor vs. an electric arc).

  • PXI Attenuator Modules

    Pickering Interfaces Ltd.

    Pickering's PXI Attenuator Modules are available in the following configurations:*Programmable RF Attenuators accurate DC to 3GHz programmable attenuator has a 1dB step resolution, allowing it to adjust signal amplitudes for optimum measurement by other devices.*Solid State Programmable RF Attenuators available in triple or hex formats with bandwidths between 10MHz and 6GHz.High Voltage *Attenuators provide a convenient way of attenuating high voltage low frequency signals to levels that can be captured by other PXI devices without risk of damaging them.

  • PXIe-S5090, 9 GHz PXI Vector Network Analyzer

    787251-01 - NI

    PXIe, 9 GHz PXI Vector Network Analyzer - The PXIe-S5090 is a 2-port Vector Network Analyzer (VNA) that helps you measure amplitude, phase, and impedance. You also can use the PXIe-S5090 to perform time-domain analysis and to calculate the S-parameters of 2-port RF devices. It features a 300 kHz to 9 GHz frequency range, a wide dynamic range, and high sweep speeds for automated design validation and production test. Additionally, the PXIe-S5090 supports automatic precision calibration, full vector analysis, and reference plane extensions.

  • Intelligent Interface Card

    IIB-1553-PCI-2C - Western Avionics Ltd.

    The IIB-1553-PCI-2C provides an intelligent interface card for two serial, dual redundant MIL-STD-1553 data buses and the PCI bus. The card supports 1553A, 1553B, McAir and STANAG 3838 variants on a single card. The IIB-1553-PCI-2C provides concurrent Bus Controller (BC) and up to 31 Remote Terminals (RT) with Bus Monitor (BM). An additional stand-alone Chronological Bus Monitor (CBM) facility is also provided, with comprehensive multi-level triggering capability. Full error injection capability is provided in BC and RT modes, with full error detection in BC, RT, BM and CBM modes. Two independent variable amplitude dual redundant 1553 interfaces are provided, each with2 Mbytes of dual ported RAM. The board is supplied with C drivers in source code and Windows menu driven software as standard.

  • Intelligent Interface Card

    IIB-1553-VXI-4C - Western Avionics Ltd.

    The IIB-1553-VXI-4C is an intelligent interface card which provides 4 independent channels for full MIL-STD-1553 test, simulation and bus analysis functions on the VXI bus. All 1553A, 1553B, McAir and STANAG 3838 variants are supported. Each independent channel may be operated as a concurrent Bus Controller (BC) and up to 31 Remote Terminals (RT) with a windowed Bus Monitor (BM), or as a stand-alone Chronological Bus Monitor (CBM) with comprehensive multi-level triggering capability. Full error injection capability is provided in BC and RT modes, with full error detection in BC, RT, BM and CBM modes. Each channel provides a variable amplitude dual redundant 1553 interface, with 2 Mbytes of dual ported RAM. The board is supplied with C drivers in source code and Windows menu driven software as standard.

  • Message Based Intelligent Interface Card

    IIB-3910-VXI - Western Avionics Ltd.

    The IIB-3910-VXI is message based intelligent interface card for dual redundant 3910 and 3838 applications. It gives full 3910 and 3838 test, simulation and bus analysis capability on the VXI bus, providing 3910, 3838 1553A, and 1553B variants in a single card. Each channel supports concurrent Bus Controller (BC) and up to 31 Remote Terminals (RT) with passive Bus Monitor, and an independent Chronological Bus Monitor (CBM). Full error injection capability is provided in BC and RT modes, with full error detection in BC, RT, BM and CBM modes. The unit provides dual redundant prEN3715 compatible 3910 interface, with variable amplitude dual redundant 3838 interfaces. External trigger-in and trigger-out are provided, with both Primary and secondary bus coupling for direct and stub bus, with access to internal 1553 bus, on the front panel.

  • Hardy Shaker

    HI-903 - Metrix

    This is our top of the line Hardy Shaker. It provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting vibration tests easier. Tests can be conducted on multiple vibration transducers, and then the saved data can be transferred via USB Flash Drive to be displayed in an automated and customizable report using an Excel template on your computer. In manual mode, the vibration test level and test frequency can be set from 7 Hz to 10,000 Hz. The high accuracy instrument can display the vibration level in terms of g’s peak, velocity peak (in/sec or mm/s) or displacement peak-to-peak (mils or µm). The unit can support payloads up to 800 grams (see frequency limits in the manual). A built-in display reads the output sensitivity, which can be stored in memory. Complete testing sequences and data can be stored in memory for each tested sensor, the unit logs the data on the spot or stores it for later use. For testing of heavy transducers or at high frequencies, the HI-903 automatically corrects the sensitivity calculation for the effects of transducer mass loading. A built-in self-test program checks for accuracy of all calculations. The HI-903 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • Preamplifiers

    Com-Power Corporation

    Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.

  • Resonant Chopper Systems

    Electro-Optical Products Corp.

    An external clock signal, to provide an ultra stable modulating optical beam motion [sub] system. The system can be used as a "stand alone" unit, in the laboratory, or can be incorporated into a larger instrument/system. The chopper is ONE FIXED FREQUENCY, picked from the range of 5 Hz to 20 kHz. The chopper is a small size, light weigh, low cost and long life device. It requires low power drive electronics and does not radiate electromagnetic interference (EMI). It has high frequency stability and high amplitude stability. The chopper is IR, VIS and UV and high vacuum capable. Reference signal and position output available.

  • HandyScope HS5 + SureConnect: 500 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 40MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS5-540XMS-W5 - TEAM SOLUTIONS, INC.

    The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 500 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.

Get Help