PXI DAQ
-
Product
PXI 8-slot BRIC Multiplexer, 12-Channel, 80-Pole (8 Sub-cards)
40-570A-116
Multiplexer Module
The 40-570A-116 is a 12-channel, 80-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
W-CDMA/HSPA+ Analysis Using NI PXI RF Test Instruments
RFmx W-CDMA/HSPA+
test
The NI-RFmx W-CDMA personality is a highly optimized API for performing physical layer measurements on W-CDMA cellular standard signals. NI-RFmx W-CDMA is completely interoperable with all NI-RFmx APIs. It provides simple access to the most advanced optimization techniques such as multi-measurement parallelism and multi-DUT measurements. The result is extremely fast and high-quality measurements with minimal software development efforts.
-
Product
12-Slot BRIC PXI Matrix, 576x16 1-Pole (18 sub-cards)
40-558-121-576X16
Matrix Switch Module
The 40-558-121-576x16 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
Product
Time Interval Counter PXI Card
GTX2200 Series
Interval Counter
The GTX22x0 family of PXI universal time interval counters offer many of the measurement and timing functions of high-end stand-alone frequency counters, including accumulate, auto ratio, frequency, fast frequency (GTX2220 and GTX2230 only), period, ratio, single period, test clock, time interval, time interval delay, totalize, totalize gated, totalize gated once, & pulse width.
-
Product
PXI Resistor Module 2-Channel 1.5R to 8.19k with SPDT
40-293-124
Programmable Resistor Module
The 40-293 is a Programmable Resistor module with two channels of 16-bit, two channels of 12-bit or four channels of 8-bit resistor chains in a single 3U PXI module. The module is ideal for simulating sensors for control and management systems under test, allowing the user to verify system response in design verification or manufacturing test applications.
-
Product
PXI 8 Slot BRIC 360x8 2-pole (12 sub-cards)
40-561A-122-360X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI Microwave Switch Modules
-
Pickering's PXI Microwave Switch Modules vary from simple multiplexer and switch configurations to integrated matrices and large multiplexers. Most products are characterized for 50 operation however certain 75 versions are supplied either as standard or custom products. Remote versions occupy a single PXI slot with the microwave switches mounted separately from the host chassis, connection to the module is via a supplied control cable.
-
Product
PXI Mixed Configuration Relay Module - 7 Cells Populated
40-138-AA-BB-CC-DD (7 CELL)
Relay
The 40-138 2A Relay Module with 7 cells populated is a cell-based mixed configuration switching module suitable for applications requiring medium power switching with high density. It provides a broad selection of mixed relay types for greater flexibility and features 2A current capacity and voltages to 300VDC/250VAC.
-
Product
Dynamically Controlled High Speed Digital I/O PXI Card
GX5150 Series
Digital I/O
The GX5150 Series are high speed, 6U PXI, sequenced digital I/O instruments. The GX5150 master controller has 32 bits of I/O channels that supports test rates of up to 50 MHz and a vector depth of up to 128 Mb per pin. The GX5151 slave offers the same timing characteristics and multiple I/O level configurations when used in conjunction with the GX5150. The GX5150 can control up to 15 GX5151 boards using the same timing and sequencer.
-
Product
PXI Pull-Thru Adapter, Wired, QuadraPaddle, to 78 Pin Female D-Sub
510140194
Pull-Thru Adapter
PXI Pull-Thru Adapter, Wired, QuadraPaddle, to 78 Pin Female D-Sub
-
Product
PXI-2585, 10‐Channel, 12 A, 1-Wire PXI Multiplexer Switch Module
778572-85
Multiplexer Module
10‐Channel, 12 A, 1-Wire PXI Multiplexer Switch Module —The PXI‑2585 is a high‐power PXI multiplexer switch module that is ideal for switching power signals and loads in control applications and battery, power supply, and automotive testing. It is configured as a 10x1 multiplexer with both low contact resistance and high isolation voltage. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
PXI Hybrid Single SP6T Switch, DC To 26.5 GHz, Terminated
M9157C
Switch Module
M9157C operates from DC to 26.5 GHz, providing a low-cost operation switching solution for measurement and automation of Automatic Test Equipment (ATE) systems without compromise in the RF performance. It is being used in applications such as ATE, RF communication and RF parametric measurements where a rugged switching module is needed for signal routing. Typical switching applications for multiport coaxial switches include signal routing to a single input to multiple instruments and routing of multiple input signals.
-
Product
PXI 8 Slot BRIC 276x16 1-Pole (12 sub-cards)
40-560A-121-276X16
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI High Density Precision Resistor Module, 4-Channel, 2.5Ω to 472Ω
40-298-120
Programmable Resistor Modules
The 40-298-120 is a high density programmable resistor module with 4 channels which can be set between 2.5Ω and 472Ω with 0.125Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
Product
Astronics PXIe-1209 , 2-Channel, 100 MHz PXI Pulse Generator
785033-01
Pulse Generator
2-Channel, 100 MHz PXI Pulse Generator - The Astronics PXIe-1209 provides dual independent pulse generation with full control of all timing parameters with extremely high resolution. Both channels are fully independent, and you can configure pulse delay, double pulse spacing, pulse width, and period. Each channel offers front panel trigger inputs with software-programmable thresholds and PXI backplane triggering.
-
Product
PXI 2-Slot BRIC Matrix, 64x16, 1 Pole (2 Sub-cards)
40-558-201-64x16
Matrix Switch Module
The 40-558-201-64x16 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
Product
PXI 12x4 Matrix, 1 Pole Screened
40-510-021-S
Matrix Switch Module
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
Product
Dual 12x4 1-Pole High-Density PXI Matrix Module
40-520-405
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI Very High Density MUX 198 Chan 1 Pole
40-675-002-198/1
Multiplexer Module
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
BNC Box-D37M To 16 SE BNC Outputs For 12-Bit PCMCIA DAQ Cards
CB516S
-
*D37M input connector*16 Single Ended BNC output channels*Connects from Ines or Elan 12-bit PCMCIA DAQ cards via CBL-T30-32-D37F cable*Only for Ines or Elan 12-bit PCMCIA DAQ cards
-
Product
PXI Dual 2 x 2 Insert/Bypass Switch FC/APC
40-860-022
-
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Product
PXI 12-Slot BRIC Matrix, 924x6 1-Pole (11 Sub-cards)
40-558-121-924X6
Matrix Switch Module
The 40-558-121-924x6 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
Product
PXI Pull-Thru Adapter, PCB, QuadraPaddle, to 68 Pin VHDCI Plug
510109473
Pull-Thru Adapter
PCB adapter from a 192 position QuadraPaddle receiver module to one 68 pin VHDCI plug
-
Product
BNC Box-D37M To 16 SE BNC Outputs For 24-Bit PCMCIA DAQ Cards
CB218S
-
*D37M input*16 Single Ended BNC Output Channels*Connects from Ines or Elan 24-bit PCMCIA DAQ cards via CBL-T30-32-D37F cable*Only for DMM i218, AD218 or AD218/i PCMCIA DAQ cards
-
Product
PXI Dual 16x8 Matrix, 2 Pole Switching
40-532-022
Matrix Switch Module
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
Product
PXI 8 Slot BRIC 230x8 1-Pole (5 sub-cards)
40-560A-121-230X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 10 Banks 0f 8 Channel 1 Pole MUX
40-615-021-10/8/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Dual 4 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-761A-002
Multiplexer Module
The 40-761A-002 terminated dual 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
HDD-8261, 4 TB, 6-Drive, PXI Data Storage Module
784192-01
Data Storage
4 TB, 6-Drive, PXI Data Storage Module - The HDD‑8261 in-chassis PXI Express high-speed data storage module features an onboard PCI Express SATA controller. The module fits into a PXI Express chassis, and it occupies only three PXI slots. With the HDD‑8261, you can choose between hard-disk drives (HDDs) or solid-state drives (SSDs) for increased ruggedness. It is ideal for field testing or signal recording applications. You can use this module to not only stream high-speed data, but also to easily move data between multiple test setups or supplement the PXI system controller’s storage capacity.
-
Product
PXI H. Density Digital I/O Module 32 Bit O/C
40-410-002
Digital I/O
The 40-410 range of Digital I/O Modules are suitable for operating external devices, such as heavy duty relays (power, RF and high voltage types), solenoids, lamps, or for interfacing with external logic such as a programmable instrument with a BCD interface. Two choices of output drive are available: TTL for interacting with external logic and Open Collector Transistor for operating external devices with voltages to 50VDC and currents to 500mA.





























