Line Replaceable Unit
unit of a complex engineered system, designed for quick replacement.
See Also: LRU
-
Product
GPU
-
The MAGIC1A is a rugged line replaceable unit (LRU) suitable for high-performance computing in the harshest of environments. The combination of Intel and NVIDIA processors in a low SWaP-C3 package ensure it can be used across a wide range of commercial and military applications, including displays, situational awareness, data/radar processing, video processing, classification, and artificial intelligence (AI).
-
Product
Avionics Suite Tester
-
Based on order from the Navy, Data Patterns developed the complete Automated Test Equipment required for validating all the Line Replaceable Units (LRUs) utilized in the Seaking Helicopter. The upgrade was carried out at multiple Naval bases in India.
-
Product
MAX629 Bus Connect
-
The MAX629 Bus Connect panel is a 19 inch rack mount or table top device to connect together ARINC 629 Line Replacement Units (LRUs) without the need for ARINC 629 couplers. This is the ideal solution for tests & simulation benches.
-
Product
Depot Repair & Redesign
-
ARC has worked with the DoD/military agencies and the FAA to help service and repair critical products in the national air system and various line replaceable units (LRUs) that may contain multiple circuit cards. With a skilled team of engineers and service technicians that can troubleshoot, reverse engineer, and help in finding components for damaged and obsolete parts, ARC is the right depot partner.
-
Product
Intermittent Fault Detection & Isolation System
IFDIS
-
The IFDIS™ uses patented Intermittent Fault Detector technology that simultaneously and continuously monitors every circuit path within a Unit Under Test (UUT) - such as a Line Replaceable Unit (LRU) chassis' interconnects - for intermittent continuity failures that occur for as short as 50 nanoseconds. This state of the art technology is combined with an environmental chamber and vibration table, which simulate the UUT’s operational environment and cause intermittent faults to manifest, creating a system that is unsurpassed in intermittent fault detection.
-
Product
72.5-Watt DC Power Line Conditioner w/Holdup
44KS3-02
Power Line Conditioner
NAI's 44KS3-02 is a 72.5-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides a single output at 72.5 Watts either 22.5 to 30 VDC with holdup time or +16 VDC without holdup time - to all downstream DC/DC converters.
-
Product
VPX55-3HU 3U VPX Power Line Conditioner with Holdu
VPX55-3HU
Power Line Conditioner
The VPX55-3HU is a 400-Watt DC/DC Power Line Conditioner which plugs directly into a standard 3U VPX chassis with a VITA 62 0.8" or 1.0" power slot. This off-the-shelf solution is compatible with VPX specifications and addresses the need for 3U VPX power applications requiring an optional VITA 62 Energy Storage Module.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
Precision Source/Measure Unit, 1 Ch, 10 FA Resolution, 210 V, 1.5 A
B2910BL
Source Measure Unit
The Keysight B2910BL Precision Source / Measure Unit (SMU) is a 1-channel, compact and cost-effective bench-top SMU with the capability to source and measure both voltage and current. It is versatile to perform I/V (current vs. voltage) measurement easily with high accuracy. Integration of 4 quadrant source and measurement capabilities enables I/V measurement simply and easily without configuring multiple instruments.
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A, Hardware Interlock
40-192A-012-HI
Fault Insertion Unit
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
Product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXIe-4142, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit
782430-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit - The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
64-Ch 1-Bus Fault Insertion
YAV91082
Fault Insertion Unit
64 channels 1 thread 2A 250V 1 Fault Insertion Buses Switching up 60W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Precision Source / Measure Unit (1 Ch, 100 FA)
B2901B
Source Measure Unit
The Keysight B2901B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
USB Source Measure Units
Source Measure Unit
The U272xA is a 3-channel USB SMU that can operate in a 4-quadrant operation. It can function as a standalone module or used as a modular device, allowing expansion and compact solution when used with the other modules in the USB Modular Instruments and DAQ family.
-
Product
PXIe-4140, 4-Channel Source Measure Unit
781742-01
Source Measure Unit
The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
Fault Insertion Unit
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXI 30A Fault Insertion Switch 6-chan 2-bus
40-191-012
Fault Insertion Unit
The 40-191-012 is a PXI fault insertion switch using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
PXI Source Measure Unit
Source Measure Unit
PXI Source Measure Units (SMUs) combine high-precision source and measure capability with features designed to reduce test time and increase flexibility. These features include high channel density for building parallel SMU test systems, deterministic hardware sequencing for minimizing software overhead, and high-speed update and sample rates for quickly changing setpoints and acquiring data. Additionally, the flexible sampling rate and streaming capability of PXI SMUs allows you to use the instrument as a digitizer to capture transient behavior, and the digital control loop gives you the ability to adjust the transient response of the instrument. The ability to change the transient behavior of the SMU, called SourceAdapt, reduces SMU settling time and minimizes overshoot and oscillations, even with highly capacitive loads.
-
Product
USB Modular Source Measure Unit
U2723A
Source Measure Unit
The 3-channel 20V/120mA module can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Optical / Electrical Clock Recovery
N1078A
Clock and Data Recovery Unit
N1078A Optical/Electrical Clock Recovery provides standards-compliant clock recovery capabilities for single-mode optical as well as electrical signals from 125 MBd up to 64 GBd PAM4 and NRZ
-
Product
Optical/Electrical Clock Recovery
N1077B
Clock and Data Recovery Unit
N1077B Optical/Electrical Clock Recovery provides standards-compliant clock recovery capabilities for multimode and single-mode optical as well as electrical signals from 125 MBd up to 64 GBd PAM4 and NRZ
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
Source Measurement Unit
SMU32
Source Measure Unit
The SMU32 is a low cost solution for V/I source and measurement. The SMU32 offers PMU/DPS in a compact, 3U PXI form factor. The SMU32 supports -1V to +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs can be ganged to DPS for high current driving.