- Pickering Interfaces Inc.
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The...show more -
product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-012
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXIe-4136, 200 V, 1 A System PXIe Source Measure Unit
783760-01
±200 V, 1 A System PXI Source Measure Unit—The PXIe‑4136 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4136 features 4-quadrant operation. Th...show more -
product
Single Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-201
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-212
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-302
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXIe-4140, 4-Channel Source Measure Unit
781742-01
The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
PXIe-4147, 4-Channel, ±8 V, 3 A Precision PXIe Source Measure Unit
786888-01
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing e...show more -
product
Source Measurement Unit
SMU4
The SMU4 offers high voltage DPS in a compact, 3U PXI form factor. The SMU4 supports -20V to +20V 100mA with FVMI, FVMV, FIMV, FIMI modes.
-
product
PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit
783762-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and ...show more -
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external sig...show more -
product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with So...show more -
product
PXIe 5-channel Precision Source/Measure Unit, 500 kSa/s, 10 pA, 30 V, 500 mA
M9615A
The Keysight M9615A is a PXIe five-channel precision source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 uV / 10 pA.
-
product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology,...show more -
product
NVIDIA GPU And Intel® Xeon® AI Computing Platform For Autonomous Drive Applications
AVA-3510
The AVA-3510 Series is powered by an Intel® Xeon® E processor coupled with workstation-grade Intel®C246 chipset to support up to 64 GB ECC DDR4 memory. The system incorporates one 2.5" SSD 256G for easy installation as optional accessories for fast read/write performance.
-
product
3U OpenVPX Sensor Interface Unit
SIU32S
The SIU32S is a highly configurable Modular Open Systems Approach (MOSA) rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, processing, communications and Ethernet switching. The SIU32S leverages NAI’s Configurable Open Systems Architecture™ (COSA®) 3U boards and smart function modules to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Based Multifunction Measurement and ICT Instrument
PXI-501
The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and genera...show more -
product
Integrated AI-ADAS ECU And Cameras For Large Commercial Vehicle
ADM-TJ30
The integrated AI-ADAS ECU is connected to 8 cameras and powered by the vision-AI algorithm. It can detect and classify different kinds of vehicles/ pedestrians/ two-wheeler riders/ lane marking and other objects to perform multiple ADAS functions.
-
product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
product
Source Measurement Unit
SMU32
The SMU32 is a low cost solution for V/I source and measurement. The SMU32 offers PMU/DPS in a compact, 3U PXI form factor. The SMU32 supports -1V to +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs can be ganged to DPS for high current driving.
-
product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-012
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
3U OpenVPX Sensor Interface Unit
SIU34
The SIU34 is a highly configurable rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, communications, Ethernet switching and processing. The SIU34 leverages NAI’s 3U OpenVPX™ boards to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
product
PXIe-4144, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit
782432-01
PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit - The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.