Hydrogen Maser Frequency References
Microwave Amplification by Stimulated Emission of Radiation
See Also: Atomic Clocks
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
RF High Frequency Probes
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
product
Redundant Reference Frequency Shaper
CH7-317
Redundant reference frequency shaper Ch7-317 is designed to generate and reproduce frequency and time signals protected from frequency and phase failures based on the results of signal processing from a group of frequency and time keepers.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
AC Reference Modules
NAI offers a variety of AC reference modules that provide a drive capability to 5 VA. The units are transformer-isolated and operate over a frequency range from 47 Hz to 10 kHz. These modules are specifically designed for rugged defense, commercial aerospace, and industrial applications.
-
product
Hydrogen Frequency & Time Standard
CH1-1033
The hydrogen frequency and time standard Ch1-1033 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main areas of application: – public service of time and frequency; – ground control complexes of radio navigation systems; – radio interferometry with extra long base.
-
product
120 GHz Frequency Extender
N5295AX01
The N5295AX01 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Reference Thermometers
Reference thermometers (standard thermometers) are, due to their excellent stability and their geometrical adaptations, ideally suited for applications in industrial laboratories. They enable easy comparative calibration in baths, in tube furnaces and in dry-well calibrators. The advantage of reference thermometers is the wide temperature range, and with this, their flexible operation. Furthermore, with their low drift, a long service life is ensured.
-
product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
product
Reference Standard
Beijing GFUVE Electronics Co.,Ltd.
It has been designed for universal laboratory and test applications and is intended for checking and the calibration of reference standards for electrical power and energy.
-
product
Oxygen/Nitrogen/Hydrogen Analyzers
EMGA-Expert
The characteristics and performance of metal and solid materials, including steel, various other metals, ceramics, and electronic materials, are determined by the amount of oxygen, nitrogen, and hydrogen. Analyzing elements in such materials at high accuracy and with a small amount has become increasingly important in the study and performance analysis of materials.The EMGA Series Oxygen/Nitrogen/Hydrogen Analyzers significantly reduces analysis time and costs while enhancing analysis accuracy and functionality. Pursuing also usability, the EMGA Series strongly supports improved efficiency in material research and development and quality control.
-
product
Reference Cells
Reference cell is used for measuring and setting the intensity of solar simulators for one sun (or other user desired) intensity condition. They are also used to calibrate the IV Measurement system photo-detector intensity to match the measured ISC to calibrated ISC.
-
product
Oxygen / Hydrogen Analyzer
ELEMENTRAC OH‑p 2
The new ELEMENTRAC OH-p 2 is a powerful and robust elemental analyzer for measurement of oxygen and hydrogen concentrations in inorganic samples like steel, iron, copper or ceramics. The highly sensitive NDIR and thermal conductivity detectors reliably detect element concentrations from low ppm content to high percentages.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Reference Standards
GF333V2
Beijing GFUVE Electronics Co.,Ltd.
Standard kWh meter is a reference standard with the characteristics of wide-range, multifunction and high-precision. It has accuracy class of 0.02. By adopting techniques of DSP, embedded system and automatic temperature balancing and other compensation, it has not only advantages of light weight, small size, high precision, high performance, powerful function, original interface, ease-to-use, but also work stability.The product can be widely used in fields of electric energy measuring, electric energy laboratories and other relevant industry, not only in laboratories but also at the industrial field.
-
product
Intelligent Time Reference
TM-4™and TM-4/OEM™
The Intelligent Reference/TM-4™ and TM4/OEM™ are multi- purpose, GPS disciplined timing signal generators and frequency references in economical off-the-shelf and custom configurations. Intended for use in a wide variety of timing, synchronization and frequency reference applications, they are based on the most advanced architecture Spectrum has ever offered, and include the most popular features of Spectrum's core platform for current timing products.
-
product
Reference Measuring System
SMG-R
Reference peak voltage meter SMG-R for precise measurement of high voltage. This PEAK voltmeter has higher accuracy and the measuring divider has a very high stability.
-
product
Emissions Reference Source
ERS
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
product
AC Reference Generators
SR25
Computer Conversions Corporation
The SR Series are miniature, low cost AC reference generators designed to supply 26 or 115 volt excitation to synchros or resolvers in military and industrial control applications. They accept +/-15V DC and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6”x3.1”x1”H.
-
product
Master Reference Generator
Mentor
Precision Time Protocol IEEE-1588 PTP grandmaster• Multiple video and audio formats in one box• Simultaneous 525/625 and HD Tri Level Sync outputs• Highly accurate GPS reference for synchronisation and timecode• Vector web-browser setup and monitoring tool• Redundant PSU option• Add upgrades and options without return to factory• Generates synchronised audio and video• Redundant units with changeover• 4K test pattern ready (future upgrade)
-
product
Reference data
The performance data of the SiTek PSDs conform to the highest standards. The device specification data are measured in a well-defined environment but are also proven to be perfectly adequate in widely diverse environments, including those of an extremely demanding nature.
-
product
Frequency Converters
Analytic Systems' Single and 3-Phase Sine-Wave Converters deliver output power ranging from 250 VA to 5000 VA. Our Frequency Converters also generate nominal output voltages of 115 VAC or 220 VAC, at frequencies of 50, 60 or 400 Hz. A broad range of input voltages are available.
-
product
Oxygen/Nitrogen/Hydrogen Analyzer
EMGA-930
This is a simultaneous oxygen, nitrogen & hydrogen elemental analyzer with high accuracy and repeatability suiting to cutting-edge technology's R&D as well as quality control in the market of steel, new materials, catalyst and so on. This is a new generation model optimized to fit to user's requests.The oxygen is measured as carbon monoxide and carbon dioxide by two non-dispersive infrared detectors, the nitrogen by a thermal conductivity detector and the hydrogen with non dispersive Infra Red detector as H2O.
-
product
Hydrogen Leak Detection System
Yamaha Fine Technologies Co., Ltd.
Yamaha Fine Tech's proprietary MEMS hydrogen sensor equipped, and a wide range of concentrations, from low to high concentrations, detectable just with one unit.A high resolution hydrogen leak detector that can detect low to high concentrations in the range from 0.5 ppm to 13,000 ppm with a single unit. Quick measurement is realized by high-speed response and real measurement. A desktop type and a handy type are available.
-
product
UV Fluorescence Hydrogen Sulfide Analyzer
Model T101
The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T101 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Reference Meter
ST1000
Shenzhen Star Instrument Co., Ltd.
The ST1000 three-phase reference meter incorporates high-precision A/D converter, DSP, wide-range measuring and embedding industrial PC technologies. It has a high accuracy of class 0.01. The voltage measuring range (phase voltage): 1V~480V, current measuring range: 1mA~120A.