Showing results: 616 - 630 of 5249 items found.
-
8666 -
TEGAM Inc.
The specially designed, shielded tip of this probes makes it ideal for monitoring moving air or gas temperatures. The exposed sensing element, located on the tip of a 3-3/4" long, 1/4" diameter, sheath, is protected by a perforated shield to minimize fluctuating readings caused by radiation or isolated gas pockets. The cord is an extendable / retractable coil-type which is 1-1/2 feet long and can extend up to 3 feet maximum.
-
Extech TH30 -
Extech Instruments Corporation
The Extech TH30 data logger is designed with a rugged housing and a standard USB connector, where stored readings (up to 48,000 data) are conveniently transferred to a PC in PDF or Excel® spreadsheet format when plugged in. Additional features include an 8-location logger bookmark, 6 language options, programmable sampling interval, adjustable alarm, and password-protected security log-in. Large LCD optimizes viewing and the smart LED provides color-coded temperature reading status.
-
Extech SD800 -
Extech Instruments Corporation
SD800 monitors air quality in schools, office buildings, greenhouses, hospitals and anywhere that high levels of carbon dioxide are generated. Selectable data sampling rate of 5, 10, 30, 60, 120, 300, 600 seconds or automatic. Maintenance free dual wavelength NDIR (non-dispersive infrared) CO2 sensor. Triple LCD simultaneously displays CO2, Temperature and Relative Humidity. Complete with six AAA batteries, 2G SD memory card, universal AC adaptor, and mounting bracket.
-
HD9817T… Series -
Delta OHM S.r.L.
Dual relative humidity and temperature transmitter for HVAC applications, environmental monitoring, pharmaceutical storage, food transport, greenhouse automation, etc. Equipped with an IP65 stainless steel AISI 304 housing, it is suitable even for severe environments; besides, its ultra-compact dimensions (Ø 14 x 133 mm) and wide range of outputs (analogue 0…1V, digital RS232C OR RS485-MODBUS RTU, USB 1.1-2.0) make it ideal for integrating into a variety of OEM applications. It is supplied with the HD9817TC software for reading measurements and calibrating the relative humidity sensor.
-
Extech SD700 -
Extech Instruments Corporation
SD700 records data to SD card in Excel format. Displays Barometric Pressure in 3 units of measure: hPa, mmHg, and inHg. Triple LCD simultaneously displays Barometric Pressure, Temperature, and Relative Humidity. Datalogger date/time stamps and stores readings on an SD card in Excel format for easy transfer to a PC. Selectable data sampling rate from 5, 10, 30, 60, 120, 300, 600 seconds. Complete with (6) AAA batteries, SD memory card, Universal AC adapter, and mounting bracket.
-
Sanwood Environmental Chambers Co ., Ltd.
Battery high low temperature test chamber is designed to test all types of batteries, including lithium-ion batteries. The battery test chamber has many safety functions built into the test chamber, which can handle battery tests and prevent safety accidents. Charge/discharge cycle testing, which determines the number of times a battery can be used by evaluating it until it deteriorates after repeated cycles of charging and discharging. In the laboratories involved in battery testing, tests based on charge and discharge cycles are a key activity. The instruments used for this type of test usually perform harsh and lengthy test protocols on the battery and can usually be connected to various instruments.
-
TGP-4520 -
Gemini Data Loggers Ltd.
This unit has connections for two external probes (not included) and is ideal for comparing ambient and process conditions or comparing two different processes.
-
TGP-4510 -
Gemini Data Loggers Ltd.
This logger has an integral sensor and a connection for an external probe (not included) that makes the unit ideal for comparing ambient and process conditions.
-
P3110E -
COMET SYSTEM, s.r.o.
The transmitter P3110E with 4-20 mA outputs is designed to measure airtemperature and relative humidity in chemically non-aggressiveenvironments.
-
CHROMA-1 -
Lisun Electronics Inc.
• Measure Pa rameters: CCT, Chromaticity Coordinate(x, y, u, v) • Display range: 1500K~25000K, Resolution: 1K • Accuracy: 0.5%F.S. • Luminance test function (lx test)
-
SIM923 -
Stanford Research Systems, Inc.
The four channels in the SIM923 have independent, stable 1 mA current sources to provide sensor excitation. Sensor resistance is determined ratiometrically with a half-bridge circuit consisting of the sensor and an internal reference resistor.
-
HD46… Series -
Delta OHM S.r.L.
The instruments of the HD46… series are transmitters, indicators and regulators suitable for measuring and monitoring the following environmental parameters, depending on the model:
-
SEM1600T -
Labfacility Ltd.
The SEM1600T accepts resistance or mV signals from RTD, Slidewire or Thermocouple sensors.
-
SCS -
Dwyer Instruments Inc.
The Series SCS Low Cost Current Switches are ideal for monitoring whether fans, pumps, or motors are operating. The current flowing through the core of the device powers the circuit without an external power supply. All models have a built in solid state output and are easy to install. Optional LED's and 10 Amp relay modules are available. The Series SCS is available in both Split and Solid Core configurations
-
Linkam Scientific Instruments
Your product descripThere are various version options for this stage, including pressure, vacuum, electrical sample measurement and sample holders to mount the stage vertically in IR or xray spectrometers.tion goes here.