Filter Results By:

Products

Applications

Manufacturers

Temperature

a measurement of heat or cold.


Showing results: 4471 - 4485 of 5231 items found.

  • Gas Permeability Tester

    EKT-2128BR - Ektron Tek Co., Ltd.

    Windows Operation Software SystemWindows operation software system provides friendly operation environment also the following characteristics: 1. User can pre-set and save the testing specifications to save time of setting procedures before test. 2. User can choose and arrange the related coordinates such as retraction value corresponding to time and temperature. 3. After tests, all test curves and related test data can be saved and retrieved for future use.

  • Grain Moisture Analyser

    Perten AM5200 - Calibre

    The AM5200 is a bench top moisture meter providing moisture and specific weight measurements in just 10 seconds. The high frequency technology penetrates deep into samples, providing more accurate analysis, regardless of temperature or crop type. This particular machine draws upon Perten’s extensive research and development with over 1,000 different types of grain moisture testing equipment, to offer unmatched analysis in terms of accuracy, repeatability and reliability.

  • Industrial Battery Manufacturing

    Analog Devices Inc.

    Analog Devices precision analog front ends and controllers for testing and monitoring battery cells simplify design by providing excellent accuracy, performance over temperature, flexibility with functionality, and overall reliability in a space saving package. Our devices measure battery charge/discharge current through precision fixed gain and programmable gain instrumentation amplifiers, and measure battery voltage via fixed gain and programmable gain difference amplifiers.

  • HALT – Highly Accelerated Life Test

    Reltech Limited

    HALT is a process used on electronic assemblies and modules to determine weaknesses and the stress limits of a product by temperature cycling and omni-axial random vibration step stress. Inherent weaknesses in a products design and build are stimulated by applying increasing levels of mechanical stress. Within an accelerated timescale, faults in a product can be realised prior to product release and preventing failures occurring during after-sale user operation, very often during the warranty period.

  • Power Metering Precision Shunt Resistore

    PMS - RARA Electronics Corporation

    These components have E-Beam welded manganese-copper alloy elements giving high strength, stability and reliability. Low thermal EMF and TCR. Small size and minimal power loss. Minimal heat generation and surface temperature due to small total resistance. Proprietary processing technique allows very low resistance values. Ideally suited for KWh meters and sampling sensor shunts. These units are also suitable for custom design.

  • Desktop Indoor Air Quality CO2

    Extech CO210 - Extech Instruments Corporation

    CO210 is a Desktop Indoor Air Quality CO2 Monitor/Datalogger. Measurement ranges are 0 to 9,999 ppm (CO2), 14 to 140°F (-10 to 60°C) for Air Temperature and 0.1 to 99.9% for Relative Humidity. It features Minimum/Maximum CO2 value recall, Year/Month/Date/Time display, and an Automatic Baseline Calibration (minimum CO2 level over 7.5 days) or manual calibration in fresh air. Comes with AC adapter and user manual.

  • Portable Ruggedized Test System

    BADGER - ADVINT, LLC

    Badger systems utilize NI's CompactRIO (cRIO), Single Board RIO (sbRIO), and/or CompactDAQ (cDAQ) hardware. The Badger product line offers high speed data acquisition/control and flexibility in an industrial package. Badger chassis and instrumentation have a 50 g shock ratings and a wide -40 to 70 °C operating temperature. These systems are ideal for automotive, industrial automation, remote monitoring, field service, and advanced control applications.

  • Walk in Chamber for Altitude Simulated Test

    Guangdong Bell Experiment Equipment Co.,Ltd

    Walk in Chamber for Altitude Simulated Test Relative Standard test requirementsTest Object: battery pack and systemTest Conditions: Altitude 4000m or the equate air pressure condition, atroom temperature.The test objects stay in the test condition as Item 2 for 5 hours.Subject the test object to 1C(no more than 400A) constant current discharge until reaching the cutoff condition.After testing, observe for 2h under the room temperature.

  • Oxidation Stability & Cold Flow Properties

    Anton Paar GmbH

    These Anton Paar instruments enable you to evaluate the oxidation stability as well as the storage and thermal stability of mineral oil products or oil and fat containing cosmetics and food samples. The gum content tester is available for tests on the gum content of fuels and other volatile distillates. Cold flow properties (cold filter plugging point and cloud and pour point) show the lowest temperature for a trouble-free operation of diesel fuel or heating oil.

  • Sharp GP2Y0A21YK0F IR Distance Sensor 10-80 Cm

    28995 - Parallax Inc.

    The Sharp GP2Y0A21YK0F infrared distance measuring sensor uses a beam of infrared light to reflect off an object to measure its distance. Because it uses triangulation of the beam of light to calculate the distance, it is able to provide consistent and reliable readings which are less sensitive to temperature variation or the object’s reflectivity. The sensor outputs an analog voltage corresponding to the distance of the object, and can easily be read using an inexpensive analog to digital converter (ADC) chip.

  • Capacitance Sensors

    Accumeasure Series - MTI Instruments

    The Accumeasure product line features capacitive sensor products for high resolution gap and displacement measurements that require a high level of accuracy that is both stable and repeatable. A capacitive sensing system consists of a probe and amplifier. Capacitive measurements can be performed in a multitude of environments using non-contact passive capacitance probes that are not affected by magnet fields, temperature, humidity, nuclear radiation, and pressure. This is largely due to the nature of the rugged and passive capacitance probes.

  • Antenna Test System

    ATS1000 - Rohde & Schwarz GmbH & Co. KG

    Offering measurements on active and passive devices - supporting also extreme temperature testing. 5G is all about data, speed and reliability using high frequency millimeter wave bands. The lack of conventional external RF connectors makes 5G antenna characterization challenging. 5G antenna, chipset and UE manufacturers as well as wireless market operators need a viable solution for research, diagnostics and debugging up to type approval.

  • Digital Telemetry Solutions

    imc Test & Measurement GmbH

    For measurements on rotating components and moving machinery, imc offers modern telemetry systems for a wide variety of tasks: whether single-channel torque monitoring of a rotating shaft, multi-channel strain gauge and temperature measurements on a train wheel-set or non-contact power measurement on a vehicle drivetrain in harsh environments. There are transmission electronics available for a large variety of sensors, such as strain gauge (quarter-, half- and full-bridge), thermocouples, PT100/1000, as well as IEPE sensors and voltage signals.

  • Portable Receivers

    SRc & SRc5P - Lectrosonics, Inc.

    The SRc5P and SRc consists of two separate receivers built into a single, ultra compact housing with adapters for video camera receiver slots and for stand-alone use. Digital Hybrid Wireless® technology provides superb, compandor-free audio quality and compatibility with other wireless systems. The RF performance is extremely stable over a very wide temperature range, making the receiver perfectly suited to the rough environmental conditions found in field production.

  • Stability Chambers

    PH Series - Darwin Chambers Company

    The Darwin Chambers PH Series Stability Chambers are designed for performance specifications exceeding FDA and ICH requirements. For GMP studies, ultrasonic humidification provides excellent humidity control and avoids hot spots during mapping. Thermoelectric cooling provides more stable temperature control than equivalent refrigeration systems. All PH series chambers incorporate inherent cooling redundancy, quiet operation, simple serviceability and excellent reliability.

Get Help