2-wire
resistance measurement method.
-
Product
Banana-Triax Adapter For 2‑Wire (Non-Kelvin) Connection
N1297A
Accessory Kit
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
Product
REM-11115, 4-Channel, 2-Wire Analog Output Module for Remote I/O
784749-01
Analog Output Module
4-Channel, 2-Wire Analog Output Module for Remote I/O - The REM‑11115 is an analog output module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11115 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. You can use the REM‑11115 for voltage or current output, and it features a 2‑wire spring terminal connection method. The REM‑11115 has selectable output ranges and short-circuit-proof output channels.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781421-14
Matrix Switch Module
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix topology With Column Protection Resistors
782385-12
Terminal Block
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
NI TB-2643B Terminal Block for NI 2532B as 1-Wire Dual 4x64 Matrix or 2-Wire 4×64 Matrix topology With Column Protection Resistors
782385-08
Terminal Block
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXI-2576, 64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module
778572-76
Multiplexer Module
64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module —The PXI‑2576 is a multibank PXI multiplexer switch module with 16 banks of 4x1 2‑wire multiplexers. With the flexible architecture of the PXI‐2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low‐channel counts, or you can combine all multiplexer banks to form a single high‐channel‐count multiplexer featuring 64 2‑wire channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays
M9120A
Matrix Switch Module
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
Product
PXIe-2739 , 256-Crosspoint, 16x16, 2-Wire PXI Matrix Switch Module
782835-39
Matrix Switch Module
256-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2739 is a high‐density 16x16 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
TB-2635, Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block
778839-01
Terminal Block
Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block - The TB-2635 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 8×16 matrix. You can directly connect the TB-2635 to the front panel I/O connectors of the PXI-2529. The TB-2635 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
Digital Power Recorder
MPR-601W-02
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and 3phase 3wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
Product
Industrial Grade PCI DIO 96 Board
MS 1817
-
*96 digital input/output lines*Support s all PPI Modes (Mode0, Mode 1 and Mode 2)*5 V TTL/CMOS*Compatible with NI DIO Card*2-wire handshaking capability*Known power-up
-
Product
In-Line IR Sensor
ILA
-
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Product
Earth Ground Tester
-
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
Product
PXI Switch - 4x8 2-Wire Matrix Module
PXI-7931
Matrix Switch Module
ADLINK PXI-7931 is a matrix module with 32 cross-point 2-wire relays (DPDT, 2 Form C). The default configuration of the PXI-7931 itself is a 4-group 2x4 2-wire matrix. With the termination board, TB-6231, users could flexibly choose one of the configurations: one 4x8, two 4x4, one 2x16, two 2x8 and four 2x4. Any contact of the PXI-7931 can connect to other contacts, individually or in combination. The PXI-7931 matrix module simplifies the wiring and makes it easy to change the internal connection path. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7931, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
Matrix Switch Module
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
ARINC interface
RAR-EC
Interface
Available in a range of configurations to match your needs, the 11 channel RAR-EC provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols, for an ExpressCard interface. The RAR-EC supports maximum data throughput on all channels while providing onboard message scheduling, label filtering, multiple buffering options, time-tagging, error detection and four avionics-level I/O discretes.
-
Product
Interface
RAR-cPCI
Interface
Available in a range of configurations to match your needs, the RAR-cPCI provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols in a CompactPCI form factor.
-
Product
Micro-Ohmmeter
3207
-
The Ballantine 4 Digit Micro-ohm Meter 3207 measures Low Resistance in Milli and micro-ohms with precise accuracy. It employs the proven 4-wire measurement technique and eliminates the lead resistance inherent in 2-wire technique to give accurate readings.
-
Product
Modbus Register Converter
Model 2390
-
* Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.
-
Product
Interface RS-485 and RS-422
-
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Product
Isolated RS-485
-
Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications. The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus.
-
Product
Multi Function Coil Tester
-
This device tests all ECU control, electronic control, or conventional distributor type ignition coils. The Tester comes with a range of connection cables with terminals to suit the majority of 2-wires, 3-wires, or 4-wires Ignition Coil of various car makes. The Ignition Coil Test is designed to detect the faults in the ignition system and whether there is any occurrence of misfire in a sluggish engine.
-
Product
Interface
RAR-PCIE
Interface
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.
-
Product
PXI Switch - 24-CH 2-Wire Multiplexer Module
PXI-7921
Matrix Switch Module
ADLINK PXI-7921 is a relay multiplexer which consists of 24 2-wire relays (DPDT, 2 Form C). As a multiplexer, the PXI-7921 provides 48x1 1-wire, 24x1 2-wire and 12x1 4-wire configurations. Users could choose one of the configurations by software. PXI-7921 typically connects one instrument, such as a DMM, a digitizer or a signal source, with many points which need measurement or excitation. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7921, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
Product
Interface
RCEI-530
Interface
Available in a range of configurations to match your needs, the RCEI-530 provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols. The RCEI-530 supports maximum data throughput on all channels while providing onboard message scheduling, label filtering, multiple buffering options, time-tagging, error detection and avionics-level I/O discretes, with support for either 33 MHz or 66 MHz PCI interfaces.
-
Product
Modbus or Laurel ASCII ProtocolSerial Output DIN Rail Transmitters
-
Laureate TM Series serial output transmitters can be jumpered for two signal levels: RS232 or RS485. Two serial protocols are selectable in software: Modbus or Laurel's Custom ASCII.Modbus protocol operation is fully compliant with the Modbus Over Serial Line Specification V1.0 (2002) for 2-wire, half-duplex connection.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 Matrix topology With Column Protection Resistors
782385-14
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
2-Wire Bus Buffers
-
Renesas' 2-wire bus buffers are designed to improve data transmission speed on SMBus or similar 2-wire serial bus interfaces.
-
Product
RS232 / RS485 / RS422 / Ethernet Surge Protectors
-
Our passive, rugged, industrial-grade RS232 / RS485 / RS422 / Ethernet surge protectors are designed for direct industrial DIN-rail mounting and they come with two (2) or three (3) stages of surge protection — Gas Discharge Tube (GDT), protection resistors, and Transient Voltage Suppressor (TVS) - for maximum protection. From 2-wire RS485, 4-wire RS422 / RS485, to 10 / 100 / 1000M Ethernet, CommFront's surge protectors safeguard your data lines and provide you with a peace of mind.
-
Product
2Wire Temp Transmitter
TS
-
● Accuracy: RTD: 0.5%, T/C: 0.75%● Wide selection of input● Low output ripple● High stability & low cost