2-wire
resistance measurement method.
-
Product
Earth Ground Tester
-
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
Product
20 Channel Multiplexer (2/4-wire) Module for DAQ970A and DAQ973A
DAQM901A
Multiplexer Module
20 Channel Multiplexer (2/4-wire) Module. High voltage switching capability of up to 300 V and built-in thermocouple reference junction.
-
Product
Door Contact Sensor
ENVIROMUX-M-DCS
-
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. Includes mounting hardware. For normally closed circuit connection. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft. Wide actuating gap, approximately 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: RoHS.
-
Product
IEC60695-11-2 Single Wire And Cable Vertical Burning Tester
CX-D12
-
Shenzhen Chuangxin Instruments Co., Ltd.
It’s strictly designed according to IEC60695-11-2, IEC60332-1, GB/T18380.11-2008, GB/T18380.12-2008 etc. Stainless steel screen with a sliding burner handle support for approaching or movingback the flame from the sample under test according to the CEI standards for test on cables.
-
Product
PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays
M9120A
Matrix Switch Module
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
Product
PXIe-2525, 64‐Channel, 2 A, Multibank, 2‐Wire PXI Multiplexer Switch Module
780587-25
Multiplexer Module
64‐Channel, 2 A, Multibank, 2‐Wire PXI Multiplexer Switch Module —The PXIe‑2525 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 2‑wire multiplexer configurations: 16 bank 4x1, octal 8x1, quad 16x1, dual 32x1, and 64x1. The PXIe‑2525 also features onboard relay counting for relay monitoring.
-
Product
- RS-232 to RS-485 2 Wire with LCD Display
Model 366
-
FEATURES: DataSpy® Status Display; Implements Low Cost LAN; Supports 32 Users; Uses Single Twisted Pair; External DTE/DCE Switch; Programmable Contention; Selectable Termination. The Model 366 allows interfacing RS-232 based equipment with networks/equipment using RS-485.
-
Product
ANSI X3.28 to Modbus RTU Converter
Model 2399
-
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
Product
REM-11115, 4-Channel, 2-Wire Analog Output Module for Remote I/O
784749-01
Analog Output Module
4-Channel, 2-Wire Analog Output Module for Remote I/O - The REM‑11115 is an analog output module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11115 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. You can use the REM‑11115 for voltage or current output, and it features a 2‑wire spring terminal connection method. The REM‑11115 has selectable output ranges and short-circuit-proof output channels.
-
Product
16-Channel Multiplexer (2 / 4-Wire) Module for DAQ970A and DAQ973A
DAQM902A
Multiplexer Module
DAQM902A 16 Channel Multiplexer (2/4-wire) Module. Reed relays with high voltage switching of up to 300 V and scan speed up to 250 ch/s.
-
Product
REM-11175, 16-Channel (Output), 24 V, 2-, 3-Wire Digital Module for Remote I/O
784745-01
Digital Module
The REM-11175 is a digital output module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and … individual modules mounted on a DIN rail. You control the REM-11175 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM-11175 features 2- and 3-wire spring terminal connection methods and circuit and overload protection.
-
Product
TB-2636, Screw Terminal, 4x32, 2-Wire PXI Module Matrix Terminal Block
196762-01
Terminal Block
The TB-2636 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 4×32 matrix. You can directly connect the TB-2636 to the front panel I/O connectors of the PXI-2529. The TB-2636 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
200-Pin Male OR 4X50-Pin To 200-Pin, 60 VDC LFH Switch Cable
779038-03
Switch Cable
The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. There are three different options for this cable. All three options have a 200-Pin, Male LFH front end connection. Each option has a different back end connection. The first option has a 200-Pin, Male Bare Wire back end connection. This option is specifically suited for the PXI-2569/70/71 and SCXI-1169. You can use the unterminated ends for custom wiring needs, twisting the channel and common terminals of the PXI-2569 and SCXI-1169 to reduce crosstalk. The second option has 4 50-Pin, Female D-Sub back end connections. This option is specifically suited for the PXI-2569/70/71 and SCXI-1169. The second option uses the same twisted-pair configuration (CH-Com Twisted) but offers 50-pin D-Sub connectivity. The third option also has 4 50-Pin, Female D-Sub back end connections, but it twists the ch+ and ch- terminals (CH-CH Twisted) when used in a 2-wire configuration. This option is specifically suited for the PXI-2575 and SCXI-1175.
-
Product
Toxic Gas Detector
SMC 4501-XX
-
The SMC 4501-XX Detector monitors toxic gases such as Hydrogen Sulfide, Carbon Monoxide, Oxygen Deficiency, Chlorine Dioxide, and others. Utilizing 2-wire loop-powered technology, the 4501-XX requires less wiring, leading to better protection from wiring errors.