2-wire
resistance measurement method.
-
Product
TB-2635, Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block
778839-01
Terminal Block
Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block - The TB-2635 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 8×16 matrix. You can directly connect the TB-2635 to the front panel I/O connectors of the PXI-2529. The TB-2635 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
TB-2636, Screw Terminal, 4x32, 2-Wire PXI Module Matrix Terminal Block
196762-01
Terminal Block
The TB-2636 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 4×32 matrix. You can directly connect the TB-2636 to the front panel I/O connectors of the PXI-2529. The TB-2636 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
PXI Switch - 24-CH 2-Wire Multiplexer Module
PXI-7921
Matrix Switch Module
ADLINK PXI-7921 is a relay multiplexer which consists of 24 2-wire relays (DPDT, 2 Form C). As a multiplexer, the PXI-7921 provides 48x1 1-wire, 24x1 2-wire and 12x1 4-wire configurations. Users could choose one of the configurations by software. PXI-7921 typically connects one instrument, such as a DMM, a digitizer or a signal source, with many points which need measurement or excitation. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7921, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
Product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix topology With Column Protection Resistors
782385-12
Terminal Block
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module
782835-37
Matrix Switch Module
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
PXIe-2529, 128-Crosspoint, 4x32 OR 8x16, 2-Wire PXI Matrix Switch Module
780587-29
Matrix Switch Module
128-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or an 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXIe‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
Matrix Switch Module
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
PXI High Density Multiplexer: 99-ch, 2-Wire, 100Vrms/1A, Armature Relays
M9103A
Multiplexer Module
The M9103A, a high-density, high-power 99-channel multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time, or multiple channels can simultaneously connect if needed. This module is ideal for routing multiple analog signals to a measurement device in an automated test environment (ATE) or data acquisition systems. Each channel switch has a high and low for 2-wire switching. The high-quality armature relays are capable of switching up to 100Vrms, with up to 60W of power. Choose from the durable connector block or standard cable connections.
-
Product
2-Wire Bus Buffers
-
Renesas' 2-wire bus buffers are designed to improve data transmission speed on SMBus or similar 2-wire serial bus interfaces.
-
Product
PXI High-Density Multiplexer: 64-ch, 2-Wire, 100Vrms/1A, Reed Relays
M9101A
Multiplexer Module
The M9101A, a high-density, 64-channel PXI multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time or, if needed multiple channels can connect simultaneously. Ideal for routing multiple analog signals to a measurement device in automated test environment (ATE) or data acquisition systems. Each channel switches a high and a low for 2-wire switching up to 100Vrms, with up to 10W of power. Connection options include the durable connector block or the standard cable connections.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
SWB-2813, 4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-13
Matrix Switch Module
4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2813 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
VXI 16-Channel, 2-Wire LVDT/RVDT Simulation
65DL1
Simulator
NAI’s 65DL1 is a 16-channel, 2-wire, LVDT/RVDT Simulation Instrument on a VXI board. This single-slot, message-based board provides 16 independent, transformer-isolated, LVDT/RVDT, programmable 2-wire outputs (up to 34 V), wrap-around self-test, and an onboard programmable excitation supply.
-
Product
Switch Mainframe
SW1002
-
Switch between voltmeter and battery tester while testing. 264 channels max. (2-wire) to 72 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.
-
Product
2Wire Temp Transmitter
TS
-
● Accuracy: RTD: 0.5%, T/C: 0.75%● Wide selection of input● Low output ripple● High stability & low cost
-
Product
Signal Conditioners
-
Process transmitters isolate, filter amplify, and convert sensor signals to 4-20mA current or 0-10V voltage signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, 3-wire DC-powered transmitters, or 4-wire AC/DC-powered transmitters. 3-wire and 4-wire models are available as 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount version are available. Configuration is easy with Windows software, push-buttons, switches, or pots for span/zero settings depending on the series.
-
Product
Keysight Dual 4x16 Armature Matrix for 34980A
34932A
Matrix Switch Module
The Keysight 34932A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x16, 8x16, or 4x32 configurations 128 2-wire cross-points 300 V, 1 A switch; 2 A carry current Connections to the internal DMM Latching armature relays, with relay counter Expandable via four 2-wire analog buses
-
Product
Serial Bus Buffers, Extenders, and Accelerators
-
The Analog Devices family of I2C solutions support hot swappable, 2-wire bidirectional bus buffers to allow I/O card insertion into a live backplane without corruption of the data and clock busses. Additional supported 2-wire buses include SMBus, PMBus, the ATCA intelligent platform management bus (IPMB), and the HDMI DDC bus. I2C/SMBus Accelerators improve bus transitions to allows multiple device connections or a longer, more capacitive interconnect, without compromising slew rates or bus performance. ADI's software-programmable and pin-selectable I2C multiplexers help resolve I2C address limitations, increase fan-in or fan-out, and integrate bus buffers and rise time accelerators for an all-in-one solution. Resistor configurable I2C address translators can be configured with over 100 unique slave addresses to allow multiple slave devices with the same address to coexist on the same bus.
-
Product
Banana-Triax Adapter For 4‑Wire (Kelvin) Connection
N1297B
-
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
Product
Digital Power Recorder
MPR-601W-01
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
Product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix Topology Without Column Protection Resistors
782385-03
Terminal Block
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXI Serial Interface Module
Serial Interface
The PXI Serial Interface Module offers a number of options for connecting to serial hardware. You can choose from common serial protocols, such as RS232, RS422, and RS485. The PXI Serial Interface Module also offers various isolation, hyperthreading, and multiprocessor compatibility options as well as 4- and 2-wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Door Contact Sensor
ENVIROMUX-M-DCS
-
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. Includes mounting hardware. For normally closed circuit connection. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft. Wide actuating gap, approximately 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: RoHS.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 Matrix topology With Column Protection Resistors
782385-14
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix Topology Without Column Protection Resistors
782385-09
Terminal Block
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Speed Sensors Dust Ignition-Proof
ST420-LT / ST420-DI
-
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected Rugged stainless steel M18x1 housing with integral conduit attachment; FM approved, dust ignition-proof. Class II, Div I (E, F, G); NEMA 4X, IP65
-
Product
Speed Sensor Intrinsically Safe
ST420
-
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected • Works with Electro-Sensors magnetic pulser discs / wraps Rugged stainless steel M18x1 housing; UL listed, Intrinsically Safe (IS); Class I, Div I (C, D) Class II, Div I (E, F, G)
-
Product
NI TB-2643B Terminal Block for NI 2532B as 1-Wire Dual 4x64 Matrix or 2-Wire 4×64 Matrix topology With Column Protection Resistors
782385-08
Terminal Block
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix topology With Column Protection Resistors
782385-04
Terminal Block
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.