Pulse Amplifiers
increase amplitude while keeping waveform. Also known as: Pulsed Amplifiers
-
Product
Solid State Power Amplifier Module (SSPA)
-
Macom Technology Solutions Holdings Inc.
MACOM’s Solid State Power Amplifier (SSPA) and waveguide module product portfolio leverages our world class MMIC technology and system design expertise for high performance Industrial, Aerospace, Defense, and Communications applications. Our SSPA modules feature up to 16 power-combined MMICs in a single module and we can power-combine multiple modules up to 100GHz featuring either coaxial or waveguide interfaces.
-
Product
900 MHz Trunk Hybrid Amplifier
AS 1111
-
Hybrid Amplifier used in trunk and branch lines specially designed to serve the need of cable systems with long trunk cables. They incorporate Good Quality Hybrid IC Module to obtain better features.- Frequency Range: 40 ~ 900 MHz- Output Level: 102 dBµV- Separate IN & OUT Fuses- Level Flatness: ±0.75 dB- 32 dB Gain (40 dB Optional)- Incorporates Good Quality- Hybrid IC Module- Hybrid IC Protected
-
Product
8 Channel Fast Amplifier
V975
-
The Mod. V975 is an 8 channel fast rise time amplifier housed in a 1-unit VME module; each channel features a fixed voltage gain of 10. Channels are bipolar, non-inverting and can be cascaded in order to obtain larger gain values. Input bandwitdth is 250 MHz for signals up to 50 mVpp and decreases for larger ones (up to 110 MHz @ 400 mVpp). Each channel is provided with three LEMO 00 connectors, one for the input and two bridged for the output.
-
Product
Panel-mounted HIL Power Amplifier
PAC60Ci
-
PAC60Ci is the six-phase real time simulation amplifier, with maximum RMS phase current of 30A and maximum output power of 450VA. This current amplifier is possessed of high accuracy and fast liner response.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
Calibration Pulse Processor
2401
-
TESCO’s Calibration Pulse Processor (Catalog No. 2401) adapts to any Next Generation three phase test board to directly calibrate with three independent single phase standards.
-
Product
Solid State Broadband High Power Amplifier
Model 2215
-
The 2215 is suitable for octave bandwidth high power CW, modulated, and pulse applications. This amplifier utilizes high power GaN devices that provide wide frequency response, high gain, high peak power capability, and low distortions. Exceptional performance, long-term reliability and high efficiency are achieved by employing advanced broadband RF matching networks and combining techniques, EMI/RFI filters, and all qualified components. The amplifier is constructed within a single 5RU drawerincluding the forced air-cooling. Available operating voltage configurations are single-phase 220 VAC up to 400 Hz and 28 VDC.
-
Product
Ultra Low Level DC Voltage Amplifiers
-
The EM A10 is a low level amplifier module for sensitive measurements, data collection and systems, where signals below 1 nanovolt may be measured. It is ideal for the input unit for precision voltage measuring systems, requiring voltage sensitivity for measuring low noise and low impedance sources. The noise level of the A10 is equivalent to a perfect resistor of about 20 ohms. When used with a digital voltmeter, steady one nanovolt digits may be displayed, with a response time constant of less than a second. The input voltage stability of the A10 is very high, with the drift around a nanovolt per degree C. The input connectors are made from pure copper. The input impedance is very high, and is time dependent, determined by the loop gain.
-
Product
Lock-In-Amplifiers
-
Current and voltage inputWorking frequency up to 45 kHzAdjustable sensitivity, time constant and phaseLocal and remote controlCompact and EMI-shielded case
-
Product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
Optical SpO2 Pulse Oximeter Simulator
OX-1 OxSim®
-
Test the complete SpO2 system, including the sensor, extension cable with the OxSim® Optical SpO2 Pulse Oximeter Simulator. Slips into your shirt pocket and operates easily with just two buttons on a single AA battery. The auto-detection of the Sensor type eliminates the need to select the manufacturer oximeter under test. The optional serial communications port enables users to expand simulation settings for Saturation, Pulse Rate, and Perfusion Index, ideal for applications where a wide range of simulations is needed.
-
Product
Instrumentation Amplifiers
-
Analog Devices instrumentation amplifiers (in-amps) are precision gain blocks that have a differential input and an output that may be differential or single-ended with respect to a reference terminal. These devices amplify the difference between two input signal voltages while rejecting any signals that are common to both inputs. The in-amps are widely used in many industrial, measurement, data acquisition, and medical applications where dc precision and gain accuracy must be maintained within a noisy environment, and where large common-mode signals (usually at the ac power line frequency) are present.
-
Product
Portable 4-Quadrant Power Amplifier
PIV270
-
PONOVO POWER's PIV270 Power Amplifier is equipped with feature of high power, large current, high voltage, high precision, high speed etc. It can meet different application on power and precision requirements.
-
Product
Composite 1×24 Video Distribution Amplifier
VDA124RM
-
Video Distribution Amplifiers (sometimes called a video splitter – not to be confused with a video split screen controller such as our PXD510E split screen controller) are typically used for connecting a camera or other video source to several monitors that do not have “looping” inputs. In this situation, each monitor has a permanent 75 ohm termination. With two non-looping monitors connected together, the line would be double loaded and result in a dim picture on each monitor. Using a Video Distribution Amplifier will solve this problem by driving each monitor individually at 100%.
-
Product
Pulse Initialization Demo Board
TMR9112
-
MultiDimension Technology Co.,Ltd.
The TMR9112 demo board was developed to support evalution of the TMR9112 single-axis sensor. The demo board comes with the fast bipolar current pulsing circuit needed for initialising the TMR9112 sensor, and it can be powered from a USB port or any external 5V power supply. For user convenience, the demo board has an optional on-board timer clock with four selectable frequency settings. The On-board timer clock and frequency output can be enabled using the jumper pins. This demo board is divisable along the dotted line so that the sensor board can be seperated from the pulsing circuit board.
-
Product
EDFA Amplifier
-
A line of Gain Flattening Erbium-Doped Fiber Amplifiers are designed for in-line amplification of DWDM networks. When a standard EDFA is used to amplify multi-channel DWDM signals, the output power level of various channels will vary according to the gain profile of the erbium fiber. This gain variation can be as great as 6 dB in magnitude. The EDFA-GB-R is unique in its dual-stage amplification and internal Gain Flattening Filter (GFF) to compensate the erbium fiber gain variation.
-
Product
Pulsed X-ray technology
-
Golden Engineering X-ray generators are based on Pulsed X-ray technology. Pulsed X-rays generate a high intensity X-ray burst (pulse) in a very short period of time (10 to 50 nanoseconds depending on the model). The output dose of each pulse is 3-6 mR measured 12 inches from the front of the X-ray generator. The operator varies the overall dose of each exposure by changing the pulse setting. The pulse rate varies from 10 pulses per second to 25 pulses per second depending on the model. The generators can fire up to 200 pulses before a four-minute rest period.
-
Product
Standard Signal Isolating Amplifier
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation and conversion of standard signals. Calibrated switchable inputs and outputs 0/4 ... 20 mA and 0 ... 10 V signal duplicator with two electrically isolated outputs.
-
Product
Ultrafast Laser Pulse Measurement
FROG Scan
-
Our FROG Scan system is versatile, adaptable and easy to use. With our FROG Scan, you can tweak a laser system or measure highly chirped pulses to calculate the amount of dispersion compensation you might need for recompression. Measure a short pulse that has been chirped out to several picoseconds, or measure pulses as short as 12 fs in real-time.
-
Product
RF POWER AMPLIFIERS
BLWA Series
-
A) RF-Sample PortsI) 3x 208 V AC / 60 HzB) External Dual Directional CouplerL) LAN Remote ControlC) IEEE-488.2 GPIB Remote ControlS) Internal RF Switching UnitD) Front Panel RF ConnectorsR) RS-232C Remote ControlE) RF Power Indication (digital)U) USB Remote ControlF) Gain AdjustmentW) Liquid CoolingH) DC SupplyX) External Control of other Amplifiers
-
Product
Pulsed SMU Systems
-
AMCAD Engineering has created professional, industry-proven pulsing technology for both pulsed-bias load pull (Pulsed Load Pull, PLP) and 50ohm transistor test applications. Systems come equipped with a mainframe controller which includes integrated power supplies and integrated input pulser with ±25V/200mA capability. The external output pulser module (probes, pulsers) is configured for 120V/30A pulsing.
-
Product
Low Noise Super Wide Band Amplifiers
WBA Series
-
WBA series low noise amplifiers have the octave bandwidth from MHz to GHz. With super low noise figure and exceptional low VSWR, WBA series LNA achieves exceptional gain flatness accross octave or multi-octave bandwidth.
-
Product
Bi-Directional Amplifiers
-
Fairview’s bi-directional amplifier models are designed for use in both commercial and military applications and will support any signal type and modulation format such as 3G and 4G telecom, WLAN, OFDM, DVB and CW/AM/FM. Fairview’s bi-directional amplifiers offer high power density, efficiency and linearity in small lightweight environmentally sealed packages with SMA connectors. These units also feature a quick-connect circular locking connector for DC and control functions and each design uses a single voltage supply with voltage regulation.
-
Product
EMI Amplifiers
-
Overvoltage protection,shuts off above 29VOver-temperature protection,shut off above +100°CExcellent IP3 Class A amplifierVSWR Short and Open circuit protection
-
Product
RF Amplifier Modules
-
Analog Devices RF amplifier modules offer high linearity, low noise figures, and low phase noise, as well as low power consumption. These devices are all fully specified over frequency and temperature for use in a variety of applications.
-
Product
General Purpose Amplifier
-
Easy to use 1.5V to 5.5V amplifiers with 69uA/ch and 150uV offsets, perfect for battery based or power concerned systems.
-
Product
RF High Power Broadband Amplifiers
-
Chengdu KeyLink Microwave Technology Co., Ltd.
Broadband amplifiers of KeyLink have exceptional RF and Microwave performance. These RF broadband amplifiers(wideband amplifiers) are available in wide frequency bands from 1 MHz to 18 GHz. Power levels for octave and multi-octave designs range from 1 watts to over 1000 watts. Applications of these broadband RF amplifiers range from radar, jamming, communication to test and measurement.
-
Product
Modular Pulse Processing Electronics
-
CAEN provides a complete and ever increasing set of instrumentation, from Preamplifiers to Data Acquisition to Triggering Electronics and Logic Functions. Most of the instrumentation is available in the most popular standard form factors and bus protocols, such as VME, NIM, CAMAC and Desktop.The Desktop is the stand alone form factor of the CAEN products. It provides the same performances of the other form factors and take the advantage of an easier and portable use, requiring no crates.
-
Product
Current Pulsers and Laser Diode Drivers (Pulsed Current)
-
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
Product
Pulse Adapter
CV30P650
-
Frothingham Electronics Corporation
The CV30 P650 test station is currently the highest voltage pulser in a series of exponential pulse generators that can be connected to our FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of high power exponential pulses. The CV30 P650 pulse adapter can produce a maximum current of 100A at up to 600V using exponential pulses up the 10/1000 waveform. The pulser is rated at 30KW from 300V to 650V. Voltage compliance at 100A is 600V. The station can also include all of the usual FEC200 tests in the same test program.