Filter Results By:

Products

Applications

Manufacturers

Showing results: 406 - 420 of 541 items found.

  • AC Insulation Testing

    Weshine Electric Manufacturing Co., Ltd

    High-voltage Dividers (High Potential Divider) are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they are used to measure alternating voltage (AC), direct voltage (DC), lightning impulse voltage (LI), and switching impulse voltage (SI) systems. High-voltage dividers by HIGHVOLT comply with the relevant IEC standards. The systems are available for both indoor and outdoor use.

  • Battery Tester

    CS-3001 - G. Jost -Electronic

    The CS-3001 test system records all block voltages, total voltage and current during a discharge test. The modular design makes it easy to connect most of all battery installations, starting from a single block and ending up with 960 block voltages. Up to four parallel strings can be tested. All measuring modules are electrically isolated (600VDC CAT III, 5000VAC test voltage).

  • Watt-MuncherPortable Load Bank

    Simplex Inc

    The Simplex Watt-Muncher is a small DC rated load bank used to test battery systems, AC to DC rectifiers and power supplies, battery chargers, UPS systems and DC generators. The Watt-Muncher provides a variable test load used to measure charge and discharge rates, response, stability and endurance. Corresponding calibrations and adjustments can be made while maintaining a constant, precise, resistive load on the power source.

  • Battery Conductance Tester

    HDGC3918 - HD Power Test Equipment Co.ltd

    HDGC3918 Battery Tester with AC discharge measurement method is used to measure the voltage and Conductance of battery, which can judge the capacity and state of heath of battery .The measurement data can be read on the instrument display directly. And it can also be uploaded to PC simply by USB drive. With the analysis software, you could not only keep a record of the testing result but also have analyzed for the status of batteries in different testing conditions.

  • Portable Holiday Detectors

    Helmut Fischer AG

    Maximum safety with high voltage generation directly in the probe head and low-energy voltage according to ISO 2746Three instrument versions with different test voltage ranges:HV5: 0.8 5 kVHV20: 4 20 kVHV40: 8 40 kVIntuitive operation with menu navigation, rotary push switch and OLED displayExtensive selection of electrodesDisplay of the test voltage applied directly to the electrode Pore detection sensitivity: detection threshold settable to a voltage drop of 10, 20, 30 or 50 %Porosity detector switchable between static and dynamic thresholdBattery operation by means of a Li-ion battery with smart battery technology, a controller monitors the battery state permanently and avoids deep discharge

  • TEM Antenna

    Techimp HQ S.r.L

    TEM antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset (like MV switchgears or LV and MV induction motors fed by power electronic impulses). It is a broadband antenna with a flat response which makes TEM suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes TEM the optimal sensor for direct installation on medium voltage Switchgears and motors. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces.

  • Battery Pack/Module Test Solution

    Chroma ATE Inc.

    Regenerative battery energy dischargeEnergy savingEnvironment protectionLow heat generateChannels paralleled for higher currentsCharge / discharge mode (CC, CV, CP) Constant current  Constant voltage  Constant powerDriving cycle simulationHigh precision measurement accuracyFast current conversionSmooth current without over shootTesting data analysis functionData recovery protection (after power failure)Independent protection of multi-channelBMS data recordingThermal chamber control integration

  • Universal PD & EMI analyzer

    Spark P3 - Manta Test Systems

    Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.

  • UHF PD Detector

    Megger Group Ltd.

    Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.

  • Battery Management Systems Testing

    Bloomy Controls, Inc.

    A Battery Management System (BMS) is an embedded unit performing critical battery functions, including cell monitoring and balancing, pack charge and discharge control, safety, and communications. The BMS must be tested early in development to optimize control algorithms, as well as during manufacturing to ensure reliable functionality. Bloomy’s family of BMS test systems provides a consistent platform for engineers to bring a BMS to market faster, and more reliably.

  • Battery Cell Insulation Tester

    Chroma 11210 - Chroma Systems Solutions, Inc.

    Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.

  • Battery Cell Testing Equipment

    Xiamen WinAck Battery Technology Co., Ltd.

    The battery cycle life tester is a high-precisionsystem designed specifically for the battery cell charge and discharge testing.It is suitable for the battery cell cycle test, battery cell charge anddischarge aging test, battery cell performance test, battery cell capacitydetection test, battery cell IR test, deep-discharging test, function test ofhigh-power lithium-ion battery cells, such as EV battery module, ES batterymodule, super capacitor…

  • Walk in Chamber for Altitude Simulated Test

    Guangdong Bell Experiment Equipment Co.,Ltd

    Walk in Chamber for Altitude Simulated Test Relative Standard test requirementsTest Object: battery pack and systemTest Conditions: Altitude 4000m or the equate air pressure condition, atroom temperature.The test objects stay in the test condition as Item 2 for 5 hours.Subject the test object to 1C(no more than 400A) constant current discharge until reaching the cutoff condition.After testing, observe for 2h under the room temperature.

  • Gas Insulated Transformer System

    YDSW Series - Shanghai Jiuzhi Electric Co., Ltd.

    SF6 insulated Test Transformers are especially designed for testing metal-clad switchgear (GIS) in the factory and in the field, and for testing the other substation equipment. It is also the portable and easy maintenance solution. The SF6 test transformers can be flanged directly to the GIS for testing which make the partial discharge test easy and quick. These systems are particularly suited for on-site tests of GIS after installation. In the factory, they are used to test sub-assemblies and components directly in the manufacturing line.

  • Lightning Surge Generator

    CDN-5810 - Shanghai Sanki Electronic Industries Co., Ltd.

    CDN-5810 signal line/data line coupling decoupling network, unshielded symmetrical communication line suitable for surge pulses and ringing wave pulses, designed according to Figure 10 of the new standard IEC61000-4-5.Ed3. It also satisfies ringing Figure 10 requirements of wave standard IEC61000-4-12.Ed2. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.

Get Help