Resistance
that which keeps current from flowing freely.
See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Replaceable General Purpose Probe
MEP-30
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Alternate 2.14 (61.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-72T38-6
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Non-contact Io/Ior Leakage Clamp Meter
MCL-800IRV
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・Calculable insulation resistance value(MΩ)by voltage & current (only in case of using direct voltage input sensors)・Available measurement for 3P/4W star connection.
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1Z-7
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Megohmmeter
1864-9700
-
The GenRad 1864 Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10VDC to 109VDC in 1-volt steps and to 1090VDC in 10 volt steps. Thus the GenRad 1864 can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. An additional range on the 1864 Megohmmeter permits measurements up to 200 T (2 x 1014)
-
Product
PXI/PXIe High Density Precision Resistor Module, 18-Channel
40-297A-013
Programmable Resistor Module
The 40-297A-013 (PXI) and the 42-297A-013 (PXIe) are 18-channel programmable resistors with a range of 1 Ω to 238 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)
CVCT-S20
-
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.
-
Product
Ground Testing
-
Weshine Electric Manufacturing Co., Ltd
1.Soil resistivity tester supports 2, 3 and 4wire grounding resistance measurement. 2. 4digit large LCD display with white screen backlight, suitable for use in dimly lit places. 3. IP65 protection grade, good waterproof, compact and portable, supports multiple functional tests.
-
Product
Mini Coaxial Contact, Receiver, RG316 Double Shield
610104149
Coax Contact (Receiver)
Mini Coaxial Contact, Receiver, RG316 Double Shield.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
Product
Original VXI Module Shield Kits
11399x Series
-
* Clamshell design fits C-size modules with 96-pin connectors.* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Component side shield has an address switch opening and non-rectangular mounting hole pattern.* Complimentary layout support includes PCB design template and CAD layout files.* RECOMMENDED FOR LEGCY APPLICATIONS ONLY due to its non-rectangular hole pattern.
-
Product
Alternate 0.99 (28.00) - 6.00 (170.00) Long Travel Bead Probe
BPLT-25HL-6
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Winding Resistance Meter 100Amps, 2 Channels
WR100-12R
-
Raytech Digital Winding Resistance meter WR100-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Regulated Transmitter
VIP 4000
-
The VIP series of Electrical transmitters are purposely designed for deep induced polarisation or Resistivity sounding investigations. The Vip injects a regulated current into the ground.
-
Product
BPLT-25 Long Travel Bead Probes
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cyles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Wound Component EST Analyzer
19036
-
Chroma 19036 is the industry's first wound component electrical safety test (EST) analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.
-
Product
Light 0.60 (17.00) - 2.00 (57.00) Bead Probe
BTP-72HF-2
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Digital Multimeter, USB Interface, 20000 Count, True RMS, Auto Range, 4.5 Digit
72-7730A
-
Digital multimeter is a 20,000 counts and 4-1/2 digits with steady operation. The meter can measure AC voltage and current, DC voltage and current, resistance, capacitance, temperature frequency, diodes, continuity, 4 to 20mA loop, Max/Min, relative mode but also has data store, data recall, AC true RMS, AC+DC, low battery display, double display backlight, automatic power off and full overload protection.
-
Product
Pokit PRO
-
Pokit Pro is an all-in-one multimeter, oscilloscope and logger with unprecedented portability, accuracy and versatility.Pokit Pro connects seamlessly to the smartphone app to measure a wide range of parameters. These include voltage, current, resistance, capacitance and temperature. It also provides continuity and diode checking.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1B-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Insulation Tester Calibrator
DecR
-
SCOPE offers High Resistance, High Voltage Decade Resistance Box - DecR. It contains number of smartly configured precision resistors. They are arranged in such a way that user can obtain desired resistance value by selecting appropriate decade switches. DecR is designed using the high quality specially selected resistors. These range of high ohm resistance decades are ideal for variety of applications, having a voltage rating up to 5 kV. It covers the resistance range from 1 kilo ohm to 1 tera ohm. DecR can also be customized as per requirement. DecR is housed in a rugged case and available in 3 / 4 / 6 / 9 decades or in binding post configuration
-
Product
Accessories for Earth Resistivity (VES)
Electrodes
-
Earth resistivity / Accessories for earth resistivity (VES)
-
Product
Environmental Control System (ECS) Tester
H301
-
The H301 Environmental Control System (ECS) Tester measures and displays parameters required to test and troubleshoot aircraft heating and air conditioning systems. These parameters include temperatures, pressures, AC and DC voltages, DC currents, and resistances.
-
Product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-H230-3
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
Alternate 17.00 (482.00) - 35.00 (992.00) Switch Probe
MSP-3C-1
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Alternate Force at switch point: 23.3 (661)Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 140Full Travel (mm): 3.56Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 2,140Overall Length (mm): 54.40Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
PXI 2 Pole 18 way Mux with 2 Pole 18 way sen
40-658-002
Multiplexer Module
This PXI multiplexer combines a 2-pole 18-way power distribution MUX with a second lower power 2-pole 18-way MUX in one convenient single slot PXI module.The module is ideal for power distribution where power and sense signals are required to be connected to an array of devices under test. This multiplexer is also convenient for making 4 wire low resistance measurements by supplying the resistor under test with high current through the power MUX and sensing the voltage drop through the sense MUX.
-
Product
True RMS Clamp Meter
DL489
-
UEi Test & Measurement Instruments
The DL489 True RMS Clamp meter offers contractors better features, functions and safety in a commemorative edition housing. A complete meter with the precision of True RMS and the functionality your job requires. Featuring 600A AC/DC, 750V AC and 1000V DC, resistance, capacitance, diode test, continuity, microamps and LRA Inrush. The DL489 is the complete meter your job requires.
-
Product
Resistance Grounded Systems (HRG/LRG)
-
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
Product
Electrostatic Discharge Simulators
ESS Series
-
EMC test equipment to evaluate the resistibility of electronic equipment when electrostatic charges on a human body or object has been discharged to the electronic equipment.This product can be used for evaluating performance degradation of any types of electronic products.
-
Product
IEC60558 Insulation Material Layer Abrasion Resistant Test Device
CX-J16
-
Shenzhen Chuangxin Instruments Co., Ltd.
This test is conforms to IEC60558-1 Fig6 and IEC60065 Fig14--16.The test shall be performed by fixing the specimens of thin sheets on a mandrel made of nickel plated steel or brass with smooth surface finish.





























