Correlators
-
product
TCSPC Lifetime Fluorometer
DeltaFlex
The DeltaFlex time correlated single photon counting (TCSPC) system is one of our Delta series of next generation time correlated single photon counting lifetime instrumentation. The DeltaFlex offers the ultimate in flexibility.
-
product
PCIe Gen3 4K at 500 Fps High Speed Compact Camera for Testing
CB160CG-LX-X8G3
4K at 500 Fps High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
product
Gas Filter Correlation CO2 Analyzer
Model N360
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Innovative Software Tool Solutions
IoT brings networking to a wide range of potential "things" ranging from everyday devices to sensors and actuators. Telchemy's management architecture is uniquely designed to handle massive numbers of devices, providing data correlation, reporting and action triggers.
-
product
Gas Filter Correlation CO Analyzer
Model T300U
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
product
Test Chambers
The left-hand axis scales the level of the 100 measurements and the right-hand axis displays the uncertainty to a statistical confidence level of 95%; proving the repeatability is better than +/-0.25dB between the measured values. Guaranteeing repeatability, accuracy and correlation across Lab’s, across Production lines and across the World
-
product
PXI-6280, 16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Hybrid, Multifunction I/O Module
779120-01
16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Multifunction I/O Module—The PXI‑6280 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Measuring Wheel
B20-S
Simple and light Measuring Wheel B20-s can measure up to 10,000m at 10cm graduation.The counter is indicated in 5 digits and has reset button. When we use Leak Noise Correlator LC-2500, we need to input the between pick-up sensors.
-
product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196B
The 16196B surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results, reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement. Now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
product
Carbon Compounds Analyzers
TML's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. All T Series analyzers offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our analyzers are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
product
Emissions Reference Source (ERS)
Emissions
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
product
Geiger Counters
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.
-
product
Partial Discharge Detection and Localization System for Power Transformers
AE-150™
The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.
-
product
Modulation Distortion Up To 26.5 GHz
S930702B
S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
PXI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Hybrid, Multifunction I/O Module
779121-01
16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXI‑6281 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
VIS/NIR Sensor
AF26
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Logger version chlorophyll and turbidity sensor with wiper
INFINITY-CLW ACLW2-USB
Infinity-CLW is an autonomously deployable data logger for long-term chlorophyll and turbidity measurements. The light sources (LEDs) of chlorophyll and turbidity sensors are highly stable, Minimizing the change over time. The instrument has a mechanical wiper that periodically sweeps to inhibit biological growth on the optical window. The turbidity sensor has a good correlation with SS (Suspended Solid) over the range. Infinity-CLW provides Highly accurate and long-term stable chlorophyll and turbidity data in oceans, rivers and freshwater.
-
product
TCSPC Lifetime Fluorometer
DeltaPro
The DeltaPro has taken the complexity of time correlated single photon counting (TCSPC) and made it simple and affordable. Any lab can exploit the power of fluorescence dynamics using TCSPC. This system enables the seamless measurement of luminescence lifetimes from picoseconds to 1 second, using our DeltaHub timing electronics.
-
product
PCIe Gen3 Full HD, High Speed, Compact Camera for Testing
CB019CG-LX-X8G3
Full HD, High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
product
PXI-6284, 32 AI (18-Bit, 625 kS/s), 48 DIO, PXI Hybrid, Multifunction I/O Module
779122-01
32 AI (18-Bit, 625 kS/s), 48 DIO, PXI Multifunction I/O Module—The PXI‑6284 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Resistance Temperature Detectors
Sensors used to measure temperature by correlating the resistance of the RTD element with temperature.
-
product
Digital Image Correlation (DIC) Measurement System
EduDIC
EduDIC is a complete Digital Image Correlation (DIC) measurement system, designed as a simple and convenient educational training tool for academic courses in experimental solid mechanics. This easy-to-use system allows academic instructors to effectively present the optical measurement technique of DIC for materials testing to the engineers and scientists of tomorrow.
-
product
Modulation Distortion For E5081A Up To 20 GHz
S960704B
The Keysight S960704B modulation distortion software application enables fast and accurate active device modulation distortion characterization under modulated signal conditions up to 20 GHz. The wide dynamic range and vector error correction of the ENA-X yield an extremely low residual EVM of the test setup, delivering a complete picture of your device’s signal distortion performance without test system interference. S960704B software measures EVM, NPR, ACPR, and decomposes linear and nonlinear signals by spectrally correlating input and output spectrum without needing to demodulate. Integration with the ENA-X measurement flexibility enables quick modulated signal distortion measurements along with traditional VNA tests.
-
product
Ex-Interface / Multiplexer
MPX0
Intelligent multiplexer for connection of correlation sensors
-
product
PXIe-6259, PXIe, 32 AI (16-Bit, 1.25 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779778-01
The PXIe-6259 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
ARINC 429 Test And Simulation USB Module
USB-429
*4, 8 or 16 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*Sorting according to SDI field*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
product
PXI-6224, 32 AI (16-Bit, 250 kS/s), 48 DIO, PXI Hybrid, Multifunction I/O Module
779114-01
32 AI (16-Bit, 250 kS/s), 48 DIO, PXI Multifunction I/O Module—The PXI‑6224 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
PXI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Hybrid, Multifunction I/O Module
779630-01
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6229 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.





























