Alternating Current
Current Alternates direction of flow cyclically. Also known as: AC
See Also: Current, Direct Current, AC
-
product
Bench Power Supply, Adjustable, Fixed, 3 Output, 0 V, 32 V, 0 A, 3 A
72-13600
*Triple channel linear DC power supply*Dual channel adjustable & one channel fixed*Constant current & constant voltage operation*Forced ventilation & temperature cooling system*LED digital tube display shows voltage and current simultaneously*Low ripple & low noise, output on/off control*Overload and reverse polarity protection*115VAC/230VAC (50Hz/60Hz) AC input voltage and 0.01% high regulation*12-month limited warranty *view Terms & Conditions for details
-
product
DMS Transmitter
Knick Elektronische Messgeräte GmbH & Co. KG.
Transmitter for load cells and the evaluation of strain gages in 6 mm housing with calibrated range selection.Detection signals from sensors for physical variables such as displacement, angle, pressure or force. Functional safety up to SIL 2, SIL 3 redundant to parameterization via interface or intuitively, directly on the device. Universal use with 24 V DC or AC power supply.
-
product
PXI Single 8x4 1-Pole 10A Power Matrix
40-551-001
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, also available with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
product
AC Insulation Testing
AC insulation tests are a popular response to the increasingly demanding industrial, power and domestic marketplaces. Insulation materials have had to become more efficient to keep up with demand; more efficient equipment requires less insulation material to meet the minimum acceptable value of insulation resistance. In turn, cables have become smaller and lighter. However, under certain higher stress testing conditions such as DC testing, cables like Crossed Linked Polyethylene (XLPE) can quickly degrade.
-
product
S Series Panel Meter
ST-100
Standard Electric Works Co., Ltd
● DC up to 50A● AC up to 50A● Case and Composition: Acrylic resin front and Bakelite case. Four studs mounting.● Accuracy : Moving coil type:Class 2.0 Moving lron type:Class 2.5 Rectifier : Class 2.0● Color:Black case. white scale plate.● Pointer:Tube or knife-type, color in black or red.
-
product
Current Transformers
Rishabh Instruments Pvt. Ltd.,
Rish Nano CT is a very reliable, efficient and robust current transformer for measurement of AC current. It provides 100 mA AC output. It can be used in Circuit breakers. Earth Leakage Protection.
-
product
Test System
Maynuo Electronic Co.,Ltd a professional R & D and production of programmable DC electronic loads, programmable DC power supply, high power load, power supply, AC power supply, power supply, such as testing high-performance mobile phone test equipment and facilities, as well as electrical, electronic, aerospace, military, chemical, automotive, battery charger, battery, solar cell production lines and other industries to provide automated testing program. The company has many years experience in a number of outstanding technical R & D, product innovation by the majority of users. We are committed to provide users with more accurate and more stable more easily accessible to the higher cost of test instruments, to create the industry in testing the influence of an international brand of excellence.
-
product
500-Watt AC/DC Power Supply
56TS1
NAI’s 56TS1 is a 500 Watt AC/DC Power Supply that accepts a 3Ø AC input or a +270 VDC input. This COTS unit provides full-power output power at a baseplate temperature of +85° C.
-
product
Regenerative AC load function
61800 Series Optional Function
The regenerative AC load function consists of various modes such as CC Rectified mode, CP Rectified mode, CR mode, CC Phase lead/lag mode and CP Phase lead/ lag mode. The Rectified Mode is capable of simulating non-linear rectified loads with characteristics similar to Chroma 63800 series AC load where the voltage and current operate at the 1st and 3rd quadrant. The Rectified Mode supports both CC and CP functions with current, power and CF as parameter settings.
-
product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
product
Mini 200 Amp AC Clamp Meter
DL6505
A compact clamp meter for use where access to cables is a problem. This instrument fits neatly in the hand and with a clamp opening of 18 mm it is ideal for those instances where it is hard to reach cables.
-
product
Field Portable Wire Analyzer
Model 2635
The perfect tester for field use is rugged, mobile, and lightweight, without sacrificing the functionality and power of a larger system. That tester is found in the Model 2635. Weighing 32 pounds (14.5 kg), this wiring analyzer handles up to 400 test points of Series 10 switching per unit. The 2635 can be powered from any AC source 100-240 VAC or 28 VDC so you can use it anywhere in the world.
-
product
3 Phase Shifter
This instrument is capable of producing 3 Phase AC Voltage with phase shifting arrangement between the phases simultaneously.
-
product
DC Isolating Transmitter
Model TW2D
Kusam Electrical Industries Limited
• 2 Inputs / 2 Outputs User Selectable• High Accuracy 0.1% RO at 23 °C ± 5 °C• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 2KV/ Min, between Input/Output/Power)
-
product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
product
64-CH Isolated Digital I/O PCI Cards
PCI-7432/7433/7434
ADLINK's cPCI/PCI-743X series cards are 64-CH high-density digital input and/or output cards that provide a robust 2,500 V isolation protection and are suitable for most industrial applications. The wide input range of the cPCI/PCI-7432 and cPCI/PCI-7433 makes it easy to sense the status of external devices. There are several options for PCI-743X series, such as normal version with input range from 0 to 24 V, as well as HIR version with high input range from 0 to 50 V. The PCI- 7433ALC is specifically designed for AC power test system.
-
product
DC to LVDT and DC to RVDT Converters
Computer Conversions Corporation
The SLVT Series are complete, low profile, continuously updating, single channel, Isolated Digital to LVDT Converters used to simulate the output of LVDT's (Linear velocity displacement transducers), RVDT's (Rotary...) and other phase/voltage sensitive AC devices. They provide a very precise linear AC voltage output proportionate to the magnitude of the input data, in or out of phase respective of the AC reference input as determined by the MSB of the input word (offset binary format).
-
product
AC Ionisation
AC Power Units
Fraser Anti-Static Techniques Ltd
A power unit designed to serve large systems
-
product
Frequency Sensor
DARE?s frequency sensors and monitors are available in both AC powered and DC powered models in a wide variety of standard or custom enclosures. Used in aircraft, ground support equipment (GSE), ground power applications, and other military and industrial applications, DARE frequency sensors, monitors, and frequency sensing relays will protect equipment that is sensitive to fluctuations in power line frequency from damage due to over and / or under frequency conditions.
-
product
AC & DC Analog Leakage Meters
1807 TB
Standard Electric Works Co., Ltd
● AC Voltage Input/output range: 100~240 Vac● Frequency: 50~60Hz● Current: 10A
-
product
Artificial Power Network
KH3765
Beijing KeHuan Century EMC Technology Co,.LTD
The KH3765 artificial power supply network is equipped with the receiver produced by our company to conduct large current conduction interference test. The frequency range of this product is 150KHz-30MHz , the current is 50A , and the AC frequency can reach 0-400Hz . It is widely used and convenient to switch. Compared with similar products on the market, it greatly reduces the operation steps and buys valuable time for your rectification work. This product also provides a standard10AThe interface makes your test more convenient. Meet the requirements of GB-6113 for power supply network.
-
product
Digital Panel Meter
This instrument is capable of producing 3 Phase AC Voltage with phase shifting arrangement between the phases simultaneously.
-
product
Frequency, Rate Meter, Flow Rate Indicator
Two independent scalable pulse-input channels from 0 Hz to 1 MHz. Channels may be combined arithmetically. One channel can display total while other displays rate. High read rate for control applications: AC line frequency can be measured to 50.0000 or 60.0000 Hz in a few line cycles. Ideal for use as a tachometer or readout of a turbine flow meter.
-
product
AC Load Banks
30 kW Series
Mosebach Manufacturing Company
Mosebach’s 30 kW series load banks offers a continuous load at either 480 or 208 volts in a very compact, lightweight, portable design with a 1kW resolution.
-
product
Current Transformers
Excellent measurement technology requires high-quality current transformers. The product portfolio comprises a wide range of current transformers for load currents (operating currents) and residual currents (RCM). Different designs cover a variety of installation situations and metrological requirements, and enable retrofitting. AC/DC sensitive measuring current transformers use a special measurement method to detect both AC and DC currents of different frequencies.
-
product
Motor Starters
Mitsubishi Electric Automation, Inc
A type of starter for AC motors that combines a magnetic contactor and an overload relay. The MS-T (10-32 amps) and MS-N (35-400 amps) series motor starters offer a compact design and provide reliable protection for your motors against overload and short-circuit conditions in any industrial application.
-
product
600 Amp DC / 400 Amp AC Current Probe
DC600
Can measure from 5 to 600 Amps DC current for most industrial DC measurement jobsNo batteries required, because power is supplied by PowerSight. This means that the probe will not stop during a long monitoring session.
-
product
AC Load Banks
X100L Series
Mosebach Manufacturing Company
Introducing Mosebach’s X100L load bank. One of the lightest dual voltage, 100 kW load banks on the market! The unit weighs approximately 64 lbs. and has 5 kW resolution. The X100L load bank includes an Industrial strength, injection molded, 100% water proof case with wheels as shown below.
-
product
PXI 5A Power MUX, 4-Bank, 11-Channel
40-651-003
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
Resistance Measuring Equipment
measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.





























