Showing results: 121 - 135 of 386 items found.
-
PDiagnostic Series -
Power Monitoring and Diagnostic Technology Ltd.
The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.
-
Earth Clamp -
Metrel d.d.
Digital measuring instrument for measurement on earthing and lightning protection systems. Specific earth resistance (soil resistance) measurement with a 4 wire method up to 30m deep.
-
3123 -
Metrel d.d.
The MI 3123 SMARTEC Earth / Clamp is an earth resistance tester with the ability to perform 4-wire earth resistance measurement and 4-wire specific earth resistance measurement. With the optional A 1018 and A 1019 current clamps the instrument can perform 4-wire earth resistance measurement with one current clamp, contactless earth resistance testing with two clamps and TRMS current measurement up to 20 A. Configurable limits enable a PASS / FAIL evaluation of test results.
-
SURE Engineering cc
The SURETECH Earth-Loss Monitor (ELM) measures the resistance to earth of cable armouring in such a way thatthe user can actually LOCATE the earth loss.
-
310123102 -
Virginia Panel Corporation
Includes all of the standard features of the iCon, in addition to Electro-Magnetic Interference (EMI) protection. An earth ground terminal is included on the and a "mate first, break last" feature connects the earth ground circuit. The earth ground terminal on the strain relief prevents user shock and injury.
-
M74 -
HT Italia Srl
M74 measures Overall earth resistance, tripping time of RCDs type AC, Insulation and Continuity of earth and equipotential conductors according to the laws in force in private electric installations.
-
Chauvin Arnoux Metrix
Continuity tester for measuring the resistance of the protective earth conductors and earth bonds – an ohmmeter dedicated to electrical safety
-
LineTroll -
Nortroll
Fault Passage Indicators to locate short circuit and earth faults.
-
DC Trace -
Scope T&M Pvt, Ltd.
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
1826 NA -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
GyroVerters -
infiniRel Corporation
The most reliable way to convert and store energy without rare earth magnets and inverters.
-
Premier Electrosystems
The typical use of high voltage testing is to confirm performance. The high voltage tests are included in type and routine tests to meet the required IS standards, quality and reliability. Some of them are insulation resistance tests, dielectric type tests, lightning and switching impulse tests, partial discharge measurement, etc. Premier's high voltage tester checks the insulation between line to earth, neutral to earth, primary to earth, secondary to earth and between primary & secondary.
-
Extech Instruments Corporation
Earth Ground Resistance Tester Kit which includes all hardware necessary to measure earth ground in 3 ranges from 20 to 2000 omega. Also tests AC/DC Voltage, resistance and continuity. Featuring Automatic zero adjustment and three earth ground resistance ranges 20Ω/200Ω/2000Ω. Complete with test leads, 2 auxiliary earth bars, carrying case, protective rubber holster and six 1.5V AA batteries.
-
4167 MF -
Standard Electric Works Co., Ltd
● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.
-
Signals & Systems India Private Limited
In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.