Filter Results By:

Products

Applications

Manufacturers

Showing results: 331 - 345 of 386 items found.

  • 180V-260V AC Socket Tester With RCD Test (For UK)

    1943 - Peaceful Thriving Enterprise Co Ltd

    *With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz

  • H.V. Multifuntion Phasing Sticks

    PC7k, PC11k, PC22k, PC33k, PC44k - Standard Electric Works Co., Ltd

    ● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.● Grounded or ungrounded systems.● Meets IEC 61481 (excludes PC44K).

  • NI-9474, 30 V, 8-Channel (Sourcing Output), 1 µs C Series Digital Module

    779003-01 - NI

    30 V, 8-Channel (Sourcing Output), 1 µs C Series Digital Module - The NI‑9474 works with industrial logic levels and signals to directly connect to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 5 V to 30 V, features transient overvoltage protection between the output channels and earth ground, and has a LED that indicates the status. The NI‑9474 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization when installed in a CompactDAQ chassis.

  • sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module

    780921-01 - NI

    Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.

  • NI-9474, 30 V, 8-Channel (Sourcing Output), 1 µs C Series Digital Module

    783908-01 - NI

    30 V, 8-Channel (Sourcing Output), 1 µs C Series Digital Module - The NI‑9474 works with industrial logic levels and signals to directly connect to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 5 V to 30 V, features transient overvoltage protection between the output channels and earth ground, and has a LED that indicates the status. The NI‑9474 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization when installed in a CompactDAQ chassis.

  • Simulation and Modeling Services for Lightning Protection

    National Technical Systems

    According to the best meteorological estimates, the surface of the earth is struck by lightning approximately 100 times each second, which averages out to about 8 million strikes per day. In addition, the Federal Aviation Administration reports that the average commercial aircraft gets hit by lightning on average about once for every 1,000 hours of flight it completes, which amounts to approximately once a year.With statistics like these, it’s obvious that providing adequate lightning protection to electrical components is crucial — whether that’s onboard an aircraft or as part of a ground-based facility. Fortunately, at NTS, we’ve been helping companies do just that for well over 50 years. Thanks to our lightning simulation and modeling services, companies are able to develop high-quality products that meet with their respective compliance regulations — from military and defense to Airbus and Boeing published standards.

  • Multifunction Instrument

    COMBI521EV - HT Italia Srl

    COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • Ohm-Stat Digital Display Megohmmeter

    Static Solutions Inc.

    Measures resistivity RTT, RTV, and RTG 103-1012 ohms/sq., ohms, ohm-cmRelative humidity 10% 90% RHTemperature 32oF 100oFDigital display: easy to interpretNIST calibration includedIncludes chair probe to measure smocks, earth ground, chairs, and resistance probes: $400 value for freeResistivity probe built in the bottom of meterProduct conforms to the ESD S.20.20 spec standardsCE mark includedThe kit includes, two (5) lb probes, coil cords, hard carrying case, battery, 110v or 220v adaptor, garment clips, chair probe, and ground circuit tester

  • NI-9206, ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module

    779526-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.

  • Digital ELCB (RCD) Tester

    1813 EL - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.

  • Digital ELCB (RCD) Tester

    2712 EL - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.

  • NI-9422, 24 V to 60 V, 8 Channel (Sinking/Sourcing Input), 250 µs C Series Digital Module

    779522-01 - NI

    24 V to 60 V, 8 Channel (Sinking/Sourcing Input), 250 µs C Series Digital Module - The NI‑9422 works with industrial logic levels and signals to directly connect to a wide array of industrial switches, transducers, and devices. Each channel accommodates 24 V to 60 V digital input signals. The NI‑9422 features channel‑to‑channel and channel‑to‑earth ground isolation for the highest level of safety for automotive and industrial environments The NI‑9422 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-01 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.