Showing results: 181 - 195 of 386 items found.
-
Earth-Rite OMEGA II -
Newson Gale Inc.
The Earth-Rite OMEGA II monitors the resistance of the static grounding circuit for processes where a risk of static charge accumulation on the equipment could result in an incendive electrostatic spark within locations that have potentially flammable atmospheres present.
-
Earth-Rite MULTIPOINT II -
Newson Gale Inc.
The Earth-Rite® MULTIPOINT II is a unique multi-channel static grounding system that can monitor the simultaneous grounding of up to eight (8) individual pieces of equipment at risk of discharging electrostatic sparks.
-
2126 NA -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Built-in earth tester.● Built-in loop/psc tester. 0.03-2000Ω (software ctrl).● Built-in voltmeter.● Built-in wiring checker.● One push button smart control.● Display L-N and L-E voltages. 50 to 280Vac (sine).● Display line path impedance. 0.01-2000Ω (software ctrl).● Display earth path impedance. 0.01-2000Ω (software ctrl).● Display neutral path impedance. 0.01-2000Ω (software ctrl).● Display psc line to neutral. 6kA@230Vac supply.● Display psc line to earth. 6kA@230Vac supply.● Re-scroll through previous results.● Bat. ok/low battery indicator.● Auto off function.● Color-coded test leads.● Rugged case.● Ultra low power consumption.
-
2726 NA -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Built-in earth tester.● Built-in loop/psc tester. 0.03-2000Ω (software ctrl).● Built-in voltmeter.● Built-in wiring checker.● One push button smart control.● Display L-N and L-E voltages. 50 to 280Vac (sine).● Display line path impedance. 0.01-2000Ω (software ctrl).● Display earth path impedance. 0.01-2000Ω (software ctrl).● Display neutral path impedance. 0.01-2000Ω (software ctrl).● Display psc line to neutral. 6kA@230Vac supply.● Display psc line to earth. 6kA@230Vac supply.● Re-scroll through previous results.● Bat. ok/low battery indicator.● Auto-off function.● Color coded test leads.● Rugged Case.● Ultra low power consumption.
-
1175 -
Draper Tools Ltd
Circuit tester with 1.5M of heavy duty cable and earth (crocodile) clip. Insulated contact point to prevent accidental shorting. Testing range 6-24V DC
-
GEM Advanced Magnetometers
VLF surveying relies on radio signals that are broadcast from navigation stations around the world. The principle is that these signals are deflected in certain ways when they pass through conductive ore or water-filled vertical-to-sub-vertial fractures in the earth. By monitoring these deflections, the position and, potentially, size of the target can be determined.
-
Cambridge Instruments & Engineering Co.
“CIE” Relay Test Set is ideal for Testing Protective relay, over current relay, earth fault relay by secondary injection method with help of digital timer.
-
Teledyne Paradise Datacom
Teledyne Paradise Datacom’s Indoor Rack Mount (-RM)series of redundant amplifier systems provide the highestdegree of earth station redundancy and reliability.These systems can be configured in either 1:1 or 1:2 redundant configurations using any of the Teledyne ParadiseDatacom family of Indoor Rack Mount SSPAs.
-
DCZCT-45NK -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
DCZCT-60NK -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
Hangzhou Xihu Electronic Institute
Including pulse current PD detecto, high frequency PD detector, transient earth PD detector, ultra high frequency PD detector, and ultrasonic PD detector.
-
LXinstruments GmbH
Testing the protective conductor is indispensable for assemblies, devices and systems of protection class I because it reduces the risk of life-threatening electrical accidents.The test checks whether the protective earth (PE) fulfils the criteria specified in the standards and can correctly discharge the current occurring in case of a fault.The ground continuity test checks whether the protective earth conductor is connected continuously to all metallic enclosure parts that can be touched by the user. The test can be carried out with low currents and voltages (simple continuity test).
-
6221 EL-M -
Standard Electric Works Co., Ltd
● High contrast OLED display.● Designed for viewing in the dark, for mining industry.● Microprocessor-controlled.● Indicates phase rotation● Indicates phase presence● TEST for disconnection sensitivity● Battery status indicator● Measures Voltage Phase to Earth● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Phase rotation and presence does not require battery to indicate.
-
LIDAR Analyst™ -
Textron Systems
Textron Systems' LIDAR Analyst software is tightly integrated with the Esri® ArcGIS® platform to provide an end-to-end solution for visualizing and processing LIDAR data. Analysts can automatically extract 3D objects such as bare earth, trees or buildings, enabling users to visualize their world for critical decision making.
-
780132-01 -
NI