Modulation Analysis
Measure and analyze radio transmitters and communication systems.
See Also: Modulation, Optical Modulation, Modulation Analyzers, Modulation Meters, MER
-
Product
NI-9476, 36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module
780175-01
Digital Module
36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module - The NI‑9476 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 36 V, based on the external power supply, and features transient overvoltage protection between the output channels and the backplane. You can programmatically monitor the built-in overcurrent and short-circuit protection status of each channel.
-
Product
PXI/PXIe High Density 2A Multiplexer, 8-Bank, 8-Channel, 2-Pole
40-614D-004
Multiplexer Module
The 40-614D-004 (PXI) and 42-614D-004 (PXIe) 8-bank, 8-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 64-Channel, 2-Pole
42-614D-016
Multiplexer Module
The 40-614D-016 (PXI) and 42-614D-016 (PXIe) 1-bank, 64-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
DC Power Module, 5V, 20A, 100W
N6741B
Power Module
The Keysight N6741B is a 100 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.
-
Product
PXI Remote Mount Triple SP6T Multiplexer 26.5GHz 50, SMA-2.9
40-785B-533-E
Multiplexer Module
The 40-785B-533-E is a remote mount triple 6-channel 26.5GHz unterminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI 8-slot BRIC Power Multiplexer, 6-Channel, 48-Pole (8 Sub-cards)
40-571A-006
Multiplexer Module
The 40-571A-006 is a 6-channel, 48-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
LXI 50Ω 6:1 Microwave Multiplexer 16-bank 40GHz SMA
60-800-416
Multiplexer Module
Our 60-800 Microwave Multiplexer range is suitable for switching 50 ohm signals up to 40GHz. With the capability of supporting up to 16 banks of 6 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA connectors.
-
Product
PXI/PXIe RF Switch, Hex SPDT, 3GHz, 50Ω, MCX
40-870A-106
Switch Module
The 40-870A-106 (PXI) and 42-870A-106 (PXIe) are 50Ω RF switches with 6 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40/42-870A has been minimized by careful attention to the mechanical and electrical design.
-
Product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass
40-860A-522-M
Multiplexer Module
The 40/42-860A-522-M is a PXI/PXIe dual insert/bypass switch with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI Dual 2 Channel Fiber MUX SC
40-855-222-M
Switch Module
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 9-Channel, 2-Pole
40-321-124-HI
Multiplexer Module
The 40-321-124-HI (PXI) and 42-321-124-HI (PXIe) are single 9-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI/PXIe High Density 2A Multiplexer, 16-Bank, 8-Channel, 1-Pole
42-614D-001
Multiplexer Module
The 40-614D-001 (PXI) and 42-614D-001 (PXIe) 16-bank, 8-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI High Density Multiplexer, 2-Bank, 64-Channel, 1-Pole
40-610A-003
Multiplexer Module
The 40-610A-003 is a 2-bank, 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 8-Channel, 8-Pole
42-614D-013
Multiplexer Module
The 40-614D-013 (PXI) and 42-614D-013 (PXIe) 2-bank, 8-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI Single 4 to 1 RF Multiplexer 2GHz 50 Ohm SMA Terminated
40-740-521
Multiplexer Module
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
Product
PXI/PXIe High Voltage Multiplexer, Dual 11-Channel, 1-Pole
42-321-105-HI
Multiplexer Module
The 40-321-105-HI (PXI) and 42-321-105-HI (PXIe) are dual 11-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
Combination SPDT/Multiplexer Module
1260-37
Multiplexer Module
The Astronics 1260-37 contains 40 Form C (SPDT) switches and eight 1x6 multiplexers. The multiplexers can be expanded using the on-board jumpers to four 1x12, two 1x24 or one 1x48 two-wire channel.
-
Product
Pneumatic Module, ITA, 5 Position (3/8" Flow)
510108144
ITA Module
The 5 Position Pneumatic Modules are made of G10 Epoxy Glass, withstanding temperatures of 140°C. Nomenclature is silk-screened white onto the Modules.
-
Product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783156-02
Signal Module
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 4-Bank 18GHz SMA
60-802-204
Multiplexer Module
The 60-802-204 is a 4-channel, 4-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
MIL-STD-1553 A / B Test And Simulation PMC Module
PMC-1553
PMC Module
*Dual redundant*1, 2 or 4 channels*Simultaneous bus controller, 31 remote terminals, bus monitor*Error entry and detection*FPGA based hardware architecture*Multi-level trigger for data acquisition and filtering*10 programmable, discrete I / O (up to 30V)*IRIG-B timecode encoder / decoder with free-running mode*Real-time recording and physical bus playback*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, LabView Real-Time and other systems*Heat sink and / or protective coating available*Optional input / output for front panel
-
Product
COM Express Basic Size Type 7 Module with Intel® Xeon® D SoC and 4 SODIMMs
Express-BD74
Computer on Module
- 4 SO-DIMMs, up to 128GB dual channel DDR4 at 1866/2133/2400MHz ECC (dependent on SoC SKU)- Intel® Xeon® D SoC (up to 16 cores)- Two 10G Ethernet and NC-SI support- Up to 32 PCIe lanes (24x Gen3, 8x Gen2)- GbE, two SATA 6 Gb/s, four USB 3.0/2.0- Supports Smart Embedded Management Agent (SEMA®) functions
-
Product
COM Express R3.1 Type 6 Compact Size Module Based On Intel® Core™ Ultra Processors
cExpress-MTL
Computer on Module
Featuring Intel’s latest Intel® Core™ Ultra processors (formerly “Meteor Lake-U/H”), the cExpress-MTL, a COM Express® COM.0 R3.1 Type 6 Compact size module, presents Intel’s modular architecture that combines CPU+GPU+NPU all-in-one to the embedded market. It provides up to 8 GPU Xe-cores (128 EUs), an 11pTOPS/8.2eTOPS NPU, and 14 CPU cores at 28W TDP.
-
Product
Multi-Channel Power Module
67394
Power Module
The 67394 Multi-Channel Power Module is a new generation of compact, stable and high reliability AC to DC power supply that can test the small size panels. It has multiple power sources with voltage/timing adjustable functions, protection functions and measurement circuits. Its modular design can work with FPD tester and PG card to provide standard power source for testing the panels.
-
Product
PXIe-5663E, 6.6 GHz PXI Vector Signal Analyzer
781339-04
Signal Module
6.6 GHz PXI Vector Signal Analyzer - The PXIe‑5663E offers wide instantaneous bandwidth and supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. You can use a PXIe‑5663E as either a spectrum analyzer or vector signal analyzer, and you can use it with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5663E can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5663E provides a low-cost solution to high-performance RF measurements.The PXIe-5663E comprises the following modules:• PXIe-5601 RF Signal Downconverter• PXIe-5622 IF Digitizer• PXIe-5652 RF Analog Signal GeneratorThere is no physical device named "PXIe-5663E".
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 40GHz, 50Ω, SMA-2.9
40-784B-142
Multiplexer Module
The 40-784B-142 (PXI) and 42-784B-142 (PXIe) are dual SP4T 40GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe High Voltage Multiplexer, Dual 4-Channel, 1-Pole
40-321-100-HI
Multiplexer Module
The 40-321-100-HI (PXI) and 42-321-100-HI (PXIe) are dual 4-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI-2554, 2.5 GHz, 75 Ω, 4x1 PXI RF Multiplexer Switch Module
778572-54
Multiplexer Module
2.5 GHz, 75 Ω, 4x1 PXI RF Multiplexer Switch Module—The PXI‑2554 is ideal for use in video RF applications where high-frequency video signal reflections can damage the source. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
COM Express® Basic Size Type 2 Module with 6th Gen Intel Core™, Intel Xeon® and Intel Celeron® Processors (formerly codename: Sky Lake-H)
Express-SL2
Computer on Module
ADLINK announces a new COM Express Type 2 Computer-on-Module, based on the highly popular Intel® Core processors (formerly codenamed Skylake and Kaby Lake). The Express-SL2/KL2 supports all type 2 related legacy I/O and thereby allows customers to extend the production life of existing type 2 based systems for at least another 10 years.





























