Phase Locked Loops
See Also: PLL
-
Product
One Phase Electric Power/Energy Calibrator
MC133
-
The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.
-
Product
Spectral Phase Measurement
Avoca SPIDER System
-
Spectral phase interferometry for direct electric-field reconstruction (SPIDER) is one technique that can recover the spectral phase of an input pulse, without needing any reference pulse. SPIDER interferes two pulses which areseparated in time and in frequency, and the resultantinterferogram is read by a spectrometer.
-
Product
4-20mA Current Loop USB Data Logger
EL-USB-4
-
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
Product
Single Phase Double Channel Energy Meter Test Equipment
SY8126
-
Hong Kong Songyang Industrial Ltd.
SY8126 single phase Energy Meter Test Equipment is a new generation, high precision, energy meter calibration equipment. It uses the international’s most advanced technology and components available in 90 decade. The equipment works under the control of keyboard or remote computer.
-
Product
Active Loop Antenna
KH30935
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH30935 active loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna has a small outer diameter and light weight, which is convenient for outdoor measurement.
-
Product
Source Phase Control
S96088B
-
The S96088B allows users to set calibrated, arbitrary phase differences between two signal sources running on the E5080B ENA.
-
Product
Surge with 3 Phase Transfer Switch Consoles
TC Model
-
(Surge with 3 Phase Transfer Switch Consoles) Although all PJ Surge Testers are capable of testing 3 Phase Motors, this "TC" Model has the same characteristics as the "C" Model, but includes a Built-in 3 Phase Test Selector Switch that facilitates 3 phase motor testing by mechanically re-positioning the ground terminal.
-
Product
Phase Sequence and Motor Rotation Tester
PRM-6
-
The PRM-6 Motor and Phase Rotation Tester can test the motor rotation of 3-phase systems, and verify 3-phase receptacle wiring and phase sequencing with test leads.
-
Product
Portable Multi Phase protection relay test set with GPS
TEST-630
-
Beijing GFUVE Electronics Co.,Ltd.
Test-630 multi Phase Universal protection relay test set have 6U6I output, it is a universal protection relay tester with eight pairs of binary input and four pairs of binary output
-
Product
3 Phase Shifter
-
This instrument is capable of producing 3 Phase AC Voltage with phase shifting arrangement between the phases simultaneously.
-
Product
3 Phase Voltage Transducer
-
Converts a three phase, 600 VAC, 50/60 Hz power system to three proportional 0 to 5 volt DC outputs.
-
Product
Dynamic Scale Deposition Loop System
-
Dynamic Scale Deposition Loop fully automated systems includes hardware and software to measure and evaluate the performance of scale inhibitors under high pressure and high temperature conditions.
-
Product
Low Voltage Single Phase
600V Class
-
These transformers are encased in a thermoplastic case with the core and windings encapsulated in resin. They are designed for line-to-line operation but may also be used in line-to-neutral or line-to-ground configuration at 58% of rated voltage. It is recommended that a 1.6 Amp fuse be used in the secondary to protect the transformer.
-
Product
Loop and Line Powered Level Switch
Safety IntelliPoint
-
The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
Product
H.V. Multifuntion Phasing Sticks
PC7k, PC11k, PC22k, PC33k, PC44k
-
Standard Electric Works Co., Ltd
● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.● Grounded or ungrounded systems.● Meets IEC 61481 (excludes PC44K).
-
Product
Low Phase Noise Amplifiers
-
Macom Technology Solutions Holdings Inc.
MACOM is committed to an expanding portfolio of low-phase noise (>150dBc/Hz @ 1k Hz offset) amplifiers for critical signal generation applications in test and measurement and defense. These offerings complement our line of NLTL GaAs comb generators.
-
Product
Short Circuit Loop Impedance Meter
AMZC-305
-
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
Product
- RS-232 to Current Loop Converter
Model 65A
-
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
Phase Noise Analyzer and VCO Tester
FSPN
Phase Noise Analyzer
The R&S®FSPN phase noise analyzer and VCO tester is designed to provide both very high sensitivity and measurement speed for production and design engineers working in these fields characterizing sources such as synthesizers, VCOs, OCXOs, and DROs. It is the ideal instrument for demanding development and production phase noise and VCO analysis.
-
Product
Single Phase Powerline Monitors
-
a Voltage disturbance detector and recorder. This device is designed to be plugged into a 120V or 240V AC line and will monitor this line for voltage disturbances and temperature or Humidity variations.
-
Product
Phase Shifters
-
Low insertion lossPhase shift adjustable up to 360°Surface mount packages as small as 0.80x.045x0.25 in.
-
Product
Phase Noise Generator / Calibrator
PNG-A
-
Noise eXtended Technologies S.A.S.
The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.
-
Product
Three Phase Round Energy Meter Test Bench Type KP-S3000-C
-
Bofa Instrument & Equipment Co., Ltd
Three phase Round energy meter test bench Type KP-S3000-C is designed for testing three-phase round energy meters (ANSI Socket type), it is mainly exported to countries in Noth America and South America. It is an ideal testing eqiupint for energy meter factory or R&D institute. All the testing procedures can be automatically operated by PC or by Keyboard manually.
-
Product
Single Loop Controller
1400+
-
The 1400+ controller is an evolved product from the West N4100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
Product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
-
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
Product
Phase Meter Current Shunts
610 and 650
-
Clarke-Hess Communications Research
The Model 610 and 650 Current Shunts are specifically designed to operate with the Model 6000A Precision Phase Meter. These shunts are frequency tuned to have negligible phase shift (less than 5m) at 50/60Hz making them ideal for line frequency applications. They can also be idealized for other frequencies as specified by the user. Consult factory for details.
-
Product
Low Phase Noise Amplifiers
-
Pasternack's low phase noise amplifiers cover select frequency bands ranging from 1.5 to 18 GHz with residual phase noise levels as low as -180 dBc/Hz @ 10 KHz offset. Additional performance specs include small signal gain ranging from 9 to 14 dB, with typical noise figure of 5.5 dB. Psat levels for these amplifiers range from +16 to +25 dBm with Output IP3 levels as high as +34 dBm. All models feature single DC voltage supplies and input/output RF ports are internally matched for 50 ohms with DC blocking capacitors. These compact module assemblies require no external components and are available in rugged Kovar metal drop-in packages that are gold-over-nickel-plated and support field replaceable SMA connectors. All models are EAR99 and guaranteed to meet MIL-STD-883 test conditions for hermeticity and temperature cycle.
-
Product
Phase Sequence Indicators (Contact Type)
887 PR
-
Standard Electric Works Co., Ltd
● Indicates phase rotation. ● Indicates phase presence.● No battery required.● Phase rotation phase presence indicated on large liquid crystal display.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 40Vac to as high as 600Vac.● Fused.● Lightweight, robust and compact.● EN 61010-1 CAT III 600V EN 61010-2-032