Electrodes
-
Product
Potentiostats
-
A potentiostat is a device that controls the potential between a pair of electrodes while measuring the resulting current flow. The resulting electrochemical plot is then used to determine various parameters relevant to the experiment.
-
Product
Meter with "3-in-1" pH/Temperature Combi Electrode
pH 5+
-
Multi-Point Calibration (up to 5 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
Product
Dielectric/Conductivity Sensor
Micro-VariconTM
-
The Micro-Varicon sensor is a miniature, thin, flexible dielectric sensor designedfor cost-sensitive use where space is limited. The electrode array is patterned on apolyimide substrate, and the Micro-Varicon sensor can be supplied with or withoutTeflon insulated leads.
-
Product
Conductivity Electrode
-
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
Product
MyoWare 2.0 Muscle Sensor
-
Using our muscles to control things is the way that most of us are accustomed to doing it. We push buttons, pull levers, move joysticks... but what if we could take the buttons, levers and joysticks out of the equation and control it with our muscles? The MyoWare® 2.0 Muscle Sensor is an Arduino-compatible, all-in-one electromyography (EMG) sensor from Advancer Technologies that allows you to do just that! The MyoWare 2.0 Muscle Sensor has been redesigned from the ground up with a new easy-to-use, compact design and upgraded with the latest and greatest chipset improving sensor performance and reliability. The innovative snap connector system eliminates the need to solder connections for the MyoWare 2.0 ecosystem. It's that easy: stick on a few electrodes (not included), read the output voltage and flex some muscles!
-
Product
Scanning Droplet Cell
VS-SDC
-
Scanning Droplet System (SDC) uses a compact peristaltic pump to force electrolyte through a small diameter tube and into a specifically designed head. This PTFE-based SDC head is machined to allow electrolyte to flow past an installed Reference Electrode and then to a port at the base of the head.
-
Product
Multichannel Pontentiostats
Arraystat Series
-
Arraystat instruments are multichannel potentiostats that utilize a common counter electrode. 25 channel potentiostat with common counter-reference electrode for combinatorial chemistry.
-
Product
Handheld Water Quality Meters
LAQUA PH210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) - 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
Product
Synchronous GPS Based I/O Controller & Interrupter
interX
-
interX was originally developed as a measurement instrument for industrial and trunk pipeline anodic or cathodic protection systems. interX allows facilitate measurement of galvanic parameters (instant-off polarized potentials, pipe-to-soil potential) across a wide range of timing cycles. It is used to make synchronous disconnect and reconnect of protection electrodes (anode or cathode) or rectifier's from/to buried underground pipeline to perform measurements.
-
Product
Model N8: Narrow Materials Moisture Meter
MRC001948
-
Designed for flat, curved, smooth, or rough surfaces such as cones or beams of yarn, rolls or stacks of cloth, and more. Electrode covers an area of 1 - 1/4 x 3 inches and penetrates 1/2 inch into the product.
-
Product
Isolation Tester UIP
-
The devices of the UIP (Union Isolations Prüfer) isolation tester series are used to test the pore-free condition of corrosion protection coatings of pipes, vessels or plant system parts. The battery-powered device generates test voltages between 5 kV and 30 kV, which are applied to the grounded test object via test electrodes. The location of a defect is signalized by a spark-over with an additional audible warning.
-
Product
Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)
HC-300F
-
HC-300F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
Product
Electrode Measurement Meter
Ion 700
-
Ion-selective electrode measurement has never been this easy – or economical! The Ion 700 measures and records up to 100 data points with 0.01 resolution.
-
Product
ELIMINOSTAT
-
This AC voltage-applied static elimination device applies a high voltage to the needle-shaped electrode of the static elimination electrode and grounds the opposing electrode, generating a corona discharge and generating air ions to neutralize the charge on a charged object. This device is available in various models, including the HDC-AC model with a built-in power supply, AC models consisting of a static elimination electrode, a high-voltage power supply, and the high-voltage cable connecting them, DC models with a built-in DC power supply, and heat-resistant AC electrodes.
-
Product
Charge Plate Monitor
-
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
Product
Bottom Electrode SMD Test Fixture
16197A
-
The 16197A is designed for impedance evaluations of bottom electrode SMDs. It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements. The Keysight 16197A supports various SMD sizes, as small as 1005 (mm)/0402 (inch) and as large as 3225 (mm)/1210 (inch). Accommodation of the 0603 (mm)/0201 (inch) size is available with option 001.
-
Product
Portable pH/mV Meter with pH electrode, temperature probe
CyberScan pH 11
-
5-point Push-Button Calibration with Auto-Buffer Recognition for quick calibration with no calibration mistakes
-
Product
Direct Burial Half Cell Reference Electrode
DB-A
-
Model DB-A Copper-Copper/Sulfate Reference Electrode designed for direct burial for long term monitoring of buried or earth contacting structures.
-
Product
Nexis GC-2030 BIDUFRGA
UFRGA Series
-
The Ultrafast RGA system utilizes the new Barrier Discharge Ionization Detector (BID) technology coupled with Nexis GC-2030 to create new system GC for ultrafast, high-sensitivity analysis. Since the electrode creating Helium plasma is totally isolated from the carrier gas, there is no chance to contaminate this electrode with a dirty sample. This enables long-term stability.
-
Product
High Voltage Thick Film Chip Resistors
HVTK (HVR)
-
*Highly reliable multilayer electrode construction*Higher component and equipment reliability*Excellent performance at high voltage*Reduced size of final equipment
-
Product
Anti-Sulfurated Thick Film Type Resistors, Precision Type
ERJ-U2R/ERJ-U3R/ERJ-U6R Series
-
Panasonic Industrial Devices Sales Company of America
High Precision And High Resistance To Sulfurization In One Resistor!Panasonic's ERJ-U2R, ERJ-U3R, ERJ-U6R (ERJ-U*R Series) offers high precision and also provides anti-sulfurization characteristics that avoid an open circuit caused by a sulfide disconnection. High resistance to sulfurization is achieved through the use of an anti-sulfurated electrode structure and material in the manufacture of ERJ-U*R Series Resistors. AEC-Q200 Compliance and IEC 60115-8, JIS C 5201-8 and JEITA RC-2134C Reference Standards for the entire ERJ-U*R Series of High Precision, Thick Film Chip Resistors from Panasonic ensures optimal quality and reliability.
-
Product
Room Temperature Sample Holders
12962A
-
The 12962A sample holder is designed to allow accurate impedance tests of solid materials to be performed at room temperature. The sample holder consists of two parallel electrodes, one of which is fixed in position and the other which can be moved into contact with the sample by adjustment of a micrometer. The sample holder makes use of guard ring and reference techniques in order to improve accuracy by reducing “fringing” effects at the edge of the sample. The standard electrode provided is 20mm diameter.
-
Product
Fire Extinguishers Testing Equipment
-
The circular electrode brush passes easily through the neck of the extinguisher cylinder and then expands to make reliable contact with the lining. Faults are detected by the voltage jumping from the electrode to the earthed shell, causing an alarm to sound. Special electrodes are available specifically for this application.
-
Product
Meter with Electrode
TDS 6+
-
Automatic or Manual Calibration - for quick, easy calibration; use automatic mode with preset calibration points at most popular values or manually set values in the manual mode for more flexibility
-
Product
Dielectric Material Test Fixture
16453A
-
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
-
Product
Electrostatic Precipitator
-
HIGHVOLT Prüftechnik Dresden GmbH
Electrostatic precipitators are used for clean process and exhaust gases, for example, in the cement and building materials industry, in steel mills, in conventional power plants, and in waste incineration plants. The dust particles are discharged electrostatically charged by a spray electrode, deflected by a DC electric field and deposited on the electrode.
-
Product
Single Cell Hardware
-
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
Product
Miniature Concentric Ring Set
PRF-912B
-
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
Product
Earth Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Earth Ground Testing. Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
Product
Plug and Switch Testing
-
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.