Electrodes
-
Product
Conductivity Sensors
-
Conductivity sensors measure the specific conductance of liquid processes. The specific conductance is directly related to the presence of ionic species and their concentration. Barben Analytical offers a full range of two electrode and four electrode contacting conductivity sensors for a variety of industrial measurement applications.
-
Product
Field-installation Type pH Meter (Two-Wire Transmission)
HP-300
-
HP-300 connects pH sensor and measures pHand temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)
HC-200NH
-
HC-200NH is an ammonia nitrogen(NH4-N) meter using ion electrode method which is designed for aeration control in wastewater treatment.
-
Product
Cross Flow Cell
-
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
Product
Universal Converter
C8000
-
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
Product
Charge Meter
NK-1001A/NK-1002A
-
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
Product
Rebar
-
Continuously monitors the coating line process as reinforcing bar runs through the RBRS dual-roller wet sponge electrodes unit. When a holiday is discovered, a red light flashes at the appropriate station on the detector unit for a visual indication, and the unit sends an eletrical output to a plug on the back of the unit. The MSRB signal output plugs drive any 120 Volt AC customer furnished horn, bell, recorder or computer.
-
Product
Galvanic DO Electrode for DO and BOD Measurements in Laboratories
9521-10D
-
- Ideal for laboratory use- Integrated with built-in temperature sensor- Comes with replaceable 7544 DO Electrode Tip, detachable BOD bottle adapter and stirrer - Use magnetic stir plate during measurement- Waterproof
-
Product
pH Electrodes
-
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
Meter With pH Electrode, ATC Probe
ION 2700
-
Intuitive, self-diagnostic and flexible with advanced set-up options for user-customization, the Eutech ION 2700 series comes with a large, one-glance-sees-all screen. View pH, ION or Redox reading together with temperature, electrode status, calibration points, date and time all at once!
-
Product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196B
Test Fixture
The 16196B surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results, reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement. Now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
Product
Long Term Test Kit
-
When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to the intake of electrons at the electrode, the chromium ion will transform to chromium oxide and be deposited at the cathode triple point. In such a case, the long term test kit is used. The Inconel 601 flange is equipped with an alumina housing (>96 % Al2O3) and the air (or other gas) is led through an alumina tube. The long term test kit is fully compatible with other functionalities proposed with the Open Flanges™ test Set-Up as the integrated steamer or the small pellet test kit. The long term test kit can be implemented on the fuel, on the air or on both sides.
-
Product
Multiplexer
-
The Ivium Technologies electrochemical multiplexer can work individual cells with 2, 3 and 4 electrodes and a WE2 (BipotentioStat, optional). Each multiplexer has 8 channels and the multiplexer units can be stacked so that up to 64 channels can be controlled sequentially by a single potentiostat.
-
Product
Handheld Water Quality Meters
LAQUA EC210
-
- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data - Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
Product
pH 2700 Benchtop Meters
-
Oakton 2700 meters meet GLP requirements - meters stamp all calibration and stored data with time/date. Nonvolatile memory stores up to 500 data sets to simplify documenting large volumes of pH or mV measurements. Meters automatically calculate and display electrode slope and offset - ideal for checking electrode quality. Order RS-232 and optional RS-232 to USB adapter separately. Advanced set-up options allow for a large degree of user customization. Datalogging intervals can be programmed into the meter for convenient continuous monitoring.
-
Product
Safety Tools Testing
-
Weshine Electric Manufacturing Co., Ltd
1. The high voltage is extremely spherical and the grounding voltage is annular.2. The grounding electrode is fixed and the high voltage electrode can be electrically driven to move to the left and right.
-
Product
ITO (Indium Tin Oxide) Electrode
-
This quite unique material transmits only visible light whereas it does not transmit UV radiation. Our ITO electrodes consist of 100 nm thick of ITO layer deposited on quartz or borosilicate glass substrate (0.5 mm thick).
-
Product
Pocket Water Quality Meters
LAQUAtwin Ca-11
-
HORIBA's unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.
-
Product
Control Relays
-
Drexelbrook manufactures a supporting line of control relays that are developed especially for use as safe, reliable, economical original equipment components in many different types of commercial and industrial products.Designed to operate from electrodes or probes contacting conductive liquids, our control relays are ideally suited for level control applications in such products as vending, dispensing, ice-making machines, water softeners, dishwashers, and coffee makers, plus many types of operating equipment in the food, drug, dairy, brewing, distilling and chemical processing industries.
-
Product
Bench pH/Conductivity/TDS Meter
CyberScan PC 510
-
Multi-parameter meters measures pH, Conductivity and TDS in single meter User-Customization for more accurate measurements with programmable functions like stability, electrode diagnosis - pH slope/offset/mV base value, etc.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Wood Moisture Meter
-
Using the principle of electrical resistance, pin-type meters use the board as an element in a circuit by driving two pins or electrodes into it. This method works because moisture conducts electricity well and dry wood is an effective insulator.
-
Product
Meter w/ pH Electrode, Conductivity/ATC Probe, Integral Electrode Holder
PC 700
-
The multi-parameter Eutech PC 700 measures pH, ORP, conductivity and temperature with a single meter. User-friendly with advanced features and a large custom-size display – perfect for research work on a budget!
-
Product
Ion/pH/mV Meter with Single Junction pH Electrode
Ion 6+
-
Direct Ion Concentration for use with most mono- or di-valent Ion Selective Electrodes (ISE) :: mV measurement mode allows you to check performance and calibration of your ISE
-
Product
Handheld Water Quality Meters
LAQUA WQ-310-K
-
- Single channel- Large colour graphic LCD screen (70 x 52 mm) with backlight - Built-in foldable meter stand- IP67 waterproof and dustproof- Battery and USB powered- Eco-friendly, shock-proof, scratch-resistant, and non-slip- Built-in sensor holders- Efficient sensor locking mechanism- Sensor's LED light as reading stability indicator- No sensor adapter needed for attaching multiple sensors together- Compatible with conventional electrodes having BNC and phono connectors and long cables- Sensor status indicator- Temperature sensor indicator- °C & °F temperature units- Sample ID setting- Detailed calibration data- Auto stable, Auto hold, and Real time measurement modes- Customizable meter kit - up to 5 meter-sensor kit combinations- Hands-free testing- Ergonomic design- Multi-language options- Versatile channel and adaptive display- Automatic sensor recognition function- Data transfer via USB or wireless communication- Printer communication- 3 years meter warranty
-
Product
Portable Conductivity/TDS Meter with Conductivity electrode
CyberScan CON 11
-
User Customizable Functions for options: Normalization Temperature, Temperature Coefficient, TDS (Total Dissolved Solids) factor, Cell constant and many more
-
Product
Plug and Switch Testing
-
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.
-
Product
Charge Plate Monitor
-
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
Product
Isolation Tester UIP
-
The devices of the UIP (Union Isolations Prüfer) isolation tester series are used to test the pore-free condition of corrosion protection coatings of pipes, vessels or plant system parts. The battery-powered device generates test voltages between 5 kV and 30 kV, which are applied to the grounded test object via test electrodes. The location of a defect is signalized by a spark-over with an additional audible warning.