Electrodes
-
Product
Electrochemistry Research Equipment
-
Our electrochemical equipment will help your group achieve laboratory and research goals. The best-selling EZstat Pro potentiostat/galvanostat can run cyclic voltammetry, electrochemical impedance spectroscopy (EIS), battery tests, and high speed galvanostatic intermittent titration technique (GITT). The EZstat HV potentiostat delivers up to 1 amp at 25 volts. The Powerstat comes in two configurations (5 amp vs 20 amp). The Duostat bipotentiostat can operate rotating ring-disk electrode experiments. The Arraystat and ArrayPGstat feature multichannel operation with different customizable options (current range, number of channels, etc.).
-
Product
Model PS-1
16820-100
-
The Model PS1 under tank probe is designed to be used in conjunction with customer-supplied ¾” National Pipe Thread (NPT) PVC piping and the product has a ¾” (NPT) threaded end that accepts a standard coupling. Any number of pipe pieces can be combined via couplings to provide the required probe insertion length under a tank. The probe can be combined with any standard reference electrode with a ¼ x 20 threaded fitting, including the RE-5, RE-5C and RE-7 portable reference electrodes. Reference electrodes are sold separately. The sealed cable to be fed through a customer-supplied PVC pipe comprises #16 AWG wire with red colored PVC insulation and the wire length can be selected via the radio buttons in the field below.
-
Product
Handheld Water Quality Meters
LAQUA PD210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Fixture and Software for Open/Leak Inspection
-
In addition to jigs and fixtures for probing conductors and electrode pads, NIDEC-READ provides specialized software for test point selection and log analysis.
-
Product
New Resistivity Inversion Software
EarthImager 3D
-
AGI is proud to introduce the new EarthImager 3D resistivity and IP inversion software. This software inverts resistivity and IP data acquired with electrodes arranged in boreholes and/or on the surface and presents a 3D volume of inverted resistivity data with advanced volume rendering technique. The final resistivity or IP image-volume can be rotated in any orientation, zoomed in and out, and translated to anywhere inside the image window in order to see the volume of interest in detail. Colors representing areas of less interest can be made transparent so that the shape of a pollution plume, for example, can be visible. With EarthImager, 3D resistivity inversion can be as easy as two steps: Read Data and Start Inversion with only a few mouse clicks.
-
Product
AA Neon Tube Tester
-
West Coast Custom Designs, LLC
When the antenna is touched to the tubing wall or electrode wires, the tester will cause the viable tubing to illuminate in a pulsating manor. This pulsing feature is fantastic for testing neon in bright sunlight as it is easier to see the light when flashing.
-
Product
Parallel Electrode SMD Test Fixture
16192A
-
The 16192A test fixture is designed for impedance evaluations of side electrode SMD components. The minimum SMD size that this fixture is adapted to evaluate is 1(L)[mm].
-
Product
Gamma Detectors
-
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
Product
Universal Converter
C8000
-
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
Product
(RDE-OES) Elemental Analyzer
SpectrOil 100 Series
-
The SpectrOil 100 Rotating Disc Electrode Optical Emission Spectrometer (RDE-OES) is the eighth generation of the market leading RDE elemental spectrometer. It is widely used in commercial oil laboratories, on-site or trailer labs, as a proven means of precisely determining elemental composition in lubricating oil, coolant, light or heavy fuels, grease, and process water. It is also a key component of Spectro’s MiniLab Series of on-site oil analysis solutions, including the best selling MiniLab 153.
-
Product
Earth Resistance Clamp Meters
-
Precision Mastech Enterprises Co.
Specialized, non-intrusive electrical testing tools designed to measure grounding system resistance without disconnecting the ground rod or using auxiliary electrodes.
-
Product
Galvanic DO Electrode for DO and BOD Measurements in Laboratories
9521-10D
-
- Ideal for laboratory use- Integrated with built-in temperature sensor- Comes with replaceable 7544 DO Electrode Tip, detachable BOD bottle adapter and stirrer - Use magnetic stir plate during measurement- Waterproof
-
Product
Franklin Tester Model
Model FT2
-
Franklin Tester Model FT-2 is designed as per IS:649 & ASTM:717 Standard to measure insulation resistivity of electrical steel sheet. It requires precision & noise free DC regulated power supply and equally distributed pressure on electrode. Franklin Tester FT-2 regulated power supply provides 0.5000V with 0.1% accuracy over load and no load. Most of national and international standard has specified only 0.5%, means FT-2 is equipped with five time better accuracy than required.
-
Product
SpectrOil M/F-W Fuel Analyzer
SpectrOil M
-
The SpectrOil M/F-W is a compact, rugged and easy to use fuel analysis spectrometer. It is designed specifically for the analysis of ash-forming contaminants in fuel such as sodium, potassium and vanadium that cause corrosion or deposits at turbine operating temperatures. It measures trace quantities of dissolved or suspended contaminant particles in a fuel sample using the time-tested and reliable rotating disc electrode (RDE) technique.
-
Product
Meter With pH Electrode, ATC Probe
ION 2700
-
Intuitive, self-diagnostic and flexible with advanced set-up options for user-customization, the Eutech ION 2700 series comes with a large, one-glance-sees-all screen. View pH, ION or Redox reading together with temperature, electrode status, calibration points, date and time all at once!
-
Product
Meter With pH Electrode, ATC Probe
pH 2700
-
Oversize screen with large fonts yet compact – the new Eutech pH 2700 offers an easy to read screen that says more! View pH or ORP readings, with temperature, electrode status, calibration points, date and time all at once!
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
Rotating Ring Disk Electrode
RRDE-3A
-
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
Product
Optical Emission Spectrometry
-
Involves applying electrical energy in the form of spark generated between an electrode and a metal sample, whereby the vaporized atoms are brought to a high energy state within a so-called "discharge plasma".
-
Product
Resistance System Kit
PMK-151
-
The PMK-151 Basic Measurement Kit has all the functionality of the PMK-152, but adds computer downloading capabilities. It contains all the instruments you need to take a variety of resistance measurements.The PMK-151 includes Prostat's PRS-801 Resistance Set with modified 5 pound conductive rubber electrodes, the PRS-801 wide range resistance meter, and Prostat PRS-801 Connectivity software for computer data downloading. You can take measurements at 10 and 100 volts with accuracy within ±5%.
-
Product
Solder Paste Wetting Tester
SP-2
-
SP-2 is wettability testing machine forsolder paste, parts electrode and PC board,adopted SP-Tension-Method (Temperature Profile Method).
-
Product
Grid Electrode
-
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
Product
Dielectric/Conductivity Sensor
VariconTM
-
The Varicon sensor is designed for use in presses, molds, bulk materials or laminates where a thin, flexible dielectric sensor is necessary. The Varicon sensor is thin enough to be implanted within a sample or between the plies of a laminate and may be discarded after use. Patterned on a polyimide substrate, the electrode array is designed to allow a choice of three sensitivities, which are selected by cutting off portions of the array at designated lines.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission)
HP-480
-
HP-480 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)
HC-200F
-
HC-200F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
Product
Principle Of Optical Emission Spectrometry
-
Optical emission spectrometry involves applying electrical energy in the form of spark generated between an electrode and a metal sample, whereby the vaporized atoms are brought to a high energy state within a so-called "discharge plasma".
-
Product
Electrodes
-
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
Product
pH 150 Waterproof Portable pH/mV/Temperature Meter
-
Rugged, accurate, reliable – Best value for an IP67-rated waterproof meter!*Intuitive, user-friendly icons—electrode status displays pH slope*Grip-Clip™ holder quickly and easily secures the electrode to your beaker or container*Expanded data logging for up to 150 data sets*mV offset for calibration of ORP standards, zeroing mV value, and pH diagnostics*700 hours battery-life or optional universal power adapter*Built-in stand and wall mount option allow for easy benchtop measurement or storage
-
Product
pH & ORP Sensors
-
The Barben Analytical Performance Series products are 3rd generation combination pH/ORP electrodes targeted at harsh, industrial measurement applications. High pressures, strong chemicals, and elevated temperatures typically shorten the lifespan of conventional double-junction pH probes. In these applications the Performance Series sensor offers extended sensor lifespan, as well as decreased drift, and longer calibration intervals. Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High-Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations. A wide selection of sensor body styles and process fittings in a variety of corrosion resistant materials allow direct replacement of short-lived OEM pH/ORP sensors. Barben Performance Series sensors are compatible with all major manufacturers of pH analyzers and transmitters. Upgrade your analytical measurement without the hassle and expense of replacing costly field instruments.





























