Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 226 - 240 of 1023 items found.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Gas-Filled Ultralight Testing Transformer

    5KVA/5KV - Wuhan Sangao Electrical Test Installations Limit Co.

    Inflatable Ultralight Non Partial Discharge Testing Transformer is a high-end testing transformer which firstly marketed in China by our company. The high-light characteristic of the equipment reflects the smallness in size, lighter in weight clean ,oil-free,unnecessary static of field investigation ,longer working life without maintenance and slightness in non-partial-discharge. It is used for the insulators' voltage-resistance testing .

  • Single Gas Transformer DGA

    GE Power

    Hydran composite gas Dissolved Gas Analysis (DGA) products provide essential online monitoring of transformer oil. The Hydran line is the perfect cost-effective application for small- and medium-sized transformers where customers need to know about developing fault conditions that could cause unscheduled outages.The Hydran products allow for the addition of expansion to the base unit, allowing for greater measurement accuracy

  • Test Set For Instrument Transformer

    NEO TELE-TRONIX PVT. LTD

    This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.

  • IEC Potential Transformer Burdens

    Eltel Industries

    • Burdens for IEC specifications rated for various input voltages available • 2.5 to 207.5 VA at 0.8 PFIEC Potential Transformer Burdens

  • Instrument Transformer Test Systems

    ZERA GmbH

    Our systems for testing voltage (VT) and current (CT) instrument transformers are conceived among other things for testing accuracy and insulation.

  • Transformer On-Load Tap-Changer Tester

    HTBYC-3000 / 256 - Wuhan Huatian Electric Power Automation Co., Ltd.

    It is mainly used for measuring the transition waveform, transition time, transient resistance of transformer on-load tap changer, three-phase synchronism, etc.

  • Transformer Test Panel/ Setup

    AJIT Electronics Co.

    This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices

  • Loss Measuring System for Transformers

    LiMOS - HIGHVOLT Prüftechnik Dresden GmbH

    The transformer loss measuring system LiMOS is designed for highly accurate measurement of losses and other parameters required in the framework of routine and type testing of power transformers. The combined voltage/current sensors and the digital signal processing enable a very compact design with only one HV device per phase with smallest volume and footprint. The digitized and preprocessed signals are transmitted via fiber optic cable to the receiver unit (LiMO-MCSU).

  • Test Sets For Transformer Industries

    NEO TELE-TRONIX PVT. LTD

    Contemporary Test Sets For Transformer Industries are developed to recognize the potentially disastrous current transformer errors. They prevent the primary current from overpowering insulation and short circuits. They are used for developing a testing and maintenance plan for addressing the errors before any failure to save money and time. With these powerful test sets, they are sure to perform saturation testing to test the knee point of a signal by comparing primary and secondary windings.

  • Differential Transformer Type Extensometers

    DT Series - Shimadzu Corp.

    ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.

  • Gas Insulated Transformer System

    YDSW Series - Shanghai Jiuzhi Electric Co., Ltd.

    SF6 insulated Test Transformers are especially designed for testing metal-clad switchgear (GIS) in the factory and in the field, and for testing the other substation equipment. It is also the portable and easy maintenance solution. The SF6 test transformers can be flanged directly to the GIS for testing which make the partial discharge test easy and quick. These systems are particularly suited for on-site tests of GIS after installation. In the factory, they are used to test sub-assemblies and components directly in the manufacturing line.

  • Automatic Current Transformer Comparator

    KATC-C2 - The Eastern Specialty Company

    Got older, slower equipment? Knopp’s Automatic Current Transformer Comparator (KATC-C2) is faster, more robust and more accurate! Knopp’s KATC-C2 is a high accuracy current comparator that is compatible with all older generation Knopp comparators, and is designed to be a direct, plug-in replacement requiring no modification of the existing Knopp Current Transformer Test Systems. Save time and money on service by upgrading your comparator to our new next generation model!

  • Transformer On-Load Tap-Changer Tester

    HTBYC-4000 / 257 - Wuhan Huatian Electric Power Automation Co., Ltd.

    Mainly used for measurement transformer with load pick up switch transition waveform, transition time, instantaneous transition resistance value, three-phase synchronism and so on.

  • High Frequency Current Transformers

    Osborne Transformer Corp.

    Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.