  • Insulation Meter

    HT7051 - HT Italia Srl

    HT7051 has been developed to measure insulation resistance with test voltage programmable up to 5kVDC and measuring range up to 10TΩ which makes it very useful in any industrial application (tests on electric machines, power transformers, electric cables, electric boards, generic devices, etc.) within BT.

  • Rigid Borescopes

    C Series - Titan Tool Supply, Inc.

    C Series small-diameter borescopes are designed for general use in inspection areas with diameters as small as 0.40" (10.2mm). 6 models cover a wide range of working lengths from 6" to 60" (152.4mm to 1524mm). Standard models include a wall-plug transformer. An optional flashlight adapter allows for in-field illumination and use.

  • Test Set With Control Unit

    Supreme Instrument Laboratories

    Single Phase A.C. High Voltage Test set (BDV Flash Test) suitable for operation on 230 Volts, A.C. 50 Hz., designed for carrying out dielectric test on transformers, electrical switchgears, and installations. It operates on single phase A.C. and provides an output voltage zero to maximum rated voltage.

  • Linear Motion Tandem Transducer

    Columbia Research Laboratories

    The Columbia Model LMT-50 is a unitized rugged package consisting of tandem linear variable differential transformers (LVDT's) with probe assembly. The LMT-50 is designed so that the likelihood of a single failure affecting both output signals is extremely improbable. The model LMT-50 offers flight proven performance, even in the most severe environments.

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Precision Capacitance and Dissipation Bridge

    SG2008 - Shanghai Jiuzhi Electric Co., Ltd.

    SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (tgδ) and capacitance (C) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test such asHigh Voltage (EHV) class Bushings, Windings of transformer (1/2/3 windings), shunt reactors, Current Transformer, Capacitor Voltage transformer(CVT), grading capacitors of Circuit Breakers, Surge Arrester and other electrical equipments. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.

  • XMC - Module VITA61/42

    XMC-1553-2-IO - ALPHI Technology Corporation

    The XMC-1553-2-IO-2 uses a DDC® Total-ACE® communication device as its 1553 bus controller, or as a remote terminal with concurrent bus monitor terminal. Dual controller has a dual redundant channel with built in transceivers and transformer. The controller has the capability to emulate up to 31 RT addresses simultaneously.

  • Electricity Meters Tester

    TE30 Lite - Calmet Smart Calibration Devices

    Electricity meters tester class 0.02%. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.

  • ST Fully-auto BDV Dielectric Oil Tester Set

    Chongqing Assen Power Equipment Co., Ltd

    ST BDV Dielectric Oil Tester is ideal for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under-test room condition in accordance with international standard.

  • Isolated Power Supplies

    Maxim Integrated

    Isolated power supplies generally include either transformers or optical isolators in both the power and the feedback paths. As a result, isolated power supplies are generally more complex in their design than nonisolated power supplies. Maxim''s isolated power ICs accommodate the necessary isolation components, thereby reducing design complexity and cost.

  • Lamp Converters

    PeakTech Prüf- und Messtechnik GmbH

    This AC / AC voltage converter is particularly suitable for use with halogen indoor lights and other low-voltage light sources that require an AC voltage source for supply. There is a safe galvanic separation between mains and low voltage according to the isolating transformer standard. This pre-assembled AC / AC converter is equipped with an overtemperature switch that cannot be reset.

  • Current Caliper

    KH23101 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.

  • Cable Electric Resistance Tester

    MR 270 C-A - Schuetz Messtechnik GmbH

    The MR270C-A is specially designed for electric resistance measurements in cable industry applications and inductive loads (transformers, motors). It is perfectly fit both for measuring the meter resistance in connection with a corresponding resistance measurement holding device or for final acceptance control of power cable reels. In the case of cable reels, which often have a cable length of several kilometers, both the compensation of the inductive component and the ability to perform measurements in the presence of high noise levels are important. This also applies to the winding resistance of transformers and motors.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

  • Automatic Insulation Oil Tester

    KVIO-80 - KV Hipot Power Test Equipment Co.,Ltd

    Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.