Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 901 - 915 of 1023 items found.

  • Test Switches and Accessories

    ABB Ltd.

    Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.

  • FTL Test Block

    SecuControl inc.

    FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.

  • Programmable Micro-Ohmmeter

    4300C - Valhalla Scientific Inc.

    The 4300C is the perfect instrument for tackling ultra-low resistance testing requirements associated with motors, transformers, fuses, connectors, breakers, bonding/weld resistance, and many other applications. The 4300C Digital Micro-Ohmmeter measures a variety of low-resistance devices ranging in value from 100nΩ to 20kΩ. The flexible measurement format of the 4300C provides six ranges of user selectable test current (from 0.1mA to 10A) and three voltage sensitivity settings (20mV, 200mV, and 2V).

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

  • Isolated LVDS

    Analog Devices Inc.

    Isolated LVDS (low voltage differential signaling) devices couple differential signals applied to the LVDS receiver inputs across the isolation barrier to the outputs on the other side and re-transmits the bit stream or clock as LVDS. Analog Devices' drop-in LVDS isolators offer designers robust, high speed differential signaling for point-to-point and multidrop applications. Extending iCoupler® chip scale transformer technology for ultrahigh speed data encoding, these LVDS isolators support a a data rate of up to 2.5 Gigabits per channel for a total bandwidth of 10 Gbps. In contrast to expensive fiber implementations, deserialized links over standard digital isolators or optocouplers, and design-intensive bespoke solutions using transformers or high voltage capacitors, ADI Gigabit Digital LVDS isolators offer the only integrated comprehensive, high performance isolation at 10 Gbps. High performance galvanic isolation for applications include analog front-end (AFE), processor to processor serial communication, or video and imaging data (such as HDMI isolators) as well as isolation between boards, or at a cable interface for LVDS or CML signal chains.

  • Power Supplies

    CF-350B - CoolMax Technology Inc.

    The CF-series power supply is built with high-quality components for extra long life and maximum system performance along with heavy duty transformers supporting high-end systems. This fanless power supply has a built-in EMI filter for a true no-noise design. The aluminum chassis is built for maximum heat relief to keep the system cool. Combined with a great ventilated structure, you’ll never need a fan. This is a true silent structure that powers your system at 480 watts efficiency.

  • Power Supplies

    CF-400B - CoolMax Technology Inc.

    The CF-series power supply is built with high-quality components for extra long life and maximum system performance along with heavy duty transformers supporting high-end systems. This fanless power supply has a built-in EMI filter for a true no-noise design. The aluminum chassis is built for maximum heat relief to keep the system cool. Combined with a great ventilated structure, you’ll never need a fan. This is a true silent structure that powers your system at 480 watts efficiency.

  • Power Supplies

    CF - SERIES - CoolMax Technology Inc.

    The CF-series power supply is built with high-quality components for extra long life and maximum system performance along with heavy duty transformers supporting high-end systems. This fanless power supply has a built-in EMI filter for a true no-noise design. The aluminum chassis is built for maximum heat relief to keep the system cool. Combined with a great ventilated structure, you’ll never need a fan. This is a true silent structure that powers your system at 480 watts efficiency.

  • Power Supplies

    CF-480B - CoolMax Technology Inc.

    The CF-series power supply is built with high-quality components for extra long life and maximum system performance along with heavy duty transformers supporting high-end systems. This fanless power supply has a built-in EMI filter for a true no-noise design. The aluminum chassis is built for maximum heat relief to keep the system cool. Combined with a great ventilated structure, you’ll never need a fan. This is a true silent structure that powers your system at 480 watts efficiency.

  • Digital Micro OHM Meter

    Neutronics Manufacturing Co.

    NMC's Digital Micro Ohm Meters are low cost, compact, light weight, 3½ digit resistance meter suitable for measurements of resistances of cables, wires, transformers, motor windings, coils and contact resistance of switches, connectors, relays and track resistance of PCB's etc. The value of resistance is displayed on 7 segment LED display. Four terminal measurement systems provide measurements free from errors due to contact resistance and test lead resistance.

  • Variable Frequency Series Resonance Test Device

    WABP - Wuhan Sangao Electrical Test Installations Limit Co.

    The device mainly AC voltage withstand test design for 10kV, 35kV, 110kV, 220kV, substation and line of all electric main equipment.Reactor with multiple separate design, Not only can meet the requirements of equipment testing conditions high voltage, small current, and can meet the requirements of low voltage AC voltage withstand test, has a wider scope of application.The device is mainly composed of variable frequency control power supply, transformer, reactor, capacitor divider.

  • 8-Channel VME LVDT/RVDT Scanner

    V550 - Highland Technology, Inc.

    The V550 is a 6U, one-slot VME module which will acquire position data from up to eight LVDT (linear variable differential transformer) position sensors. The LVDT sensors are excited by an ultrastable synthesized sinewave generator, and conditioned by a precision 16-bit A/D converter followed by digital signal processing. The resident microprocessor supervises scanning and signal conditioning, and places updated position data in VME-accessible dual-ported data registers for instant access from the VME bus.

  • Oil Test Set

    NEO TELE-TRONIX PVT. LTD

    We are the most reliable manufacturer and exporter of Oil Test Set that is ideal for testing of Breakdown / Withstand Test of Transformer and Circuit Breaker Oil. This test set is manufactured using premium quality raw material under the supervision of versed professionals. Moreover, the offered test set is checked by our quality inspectors on various parameters to ensure its flawlessness at clients' end. Our valuable clients can avail this Oil Test Set from us at competitive prices.

  • High Voltage Test Set

    Hi-Pot Series - Scope T&M Pvt, Ltd.

    SCOPE introduces a high voltage test set, these high voltage testing sets comes with Power frequency AC high voltage /DC high Voltage test /AC-DC high Voltage test set for testing transformers, motors, insulators, cables etc. Further, these testing sets are capable of giving continuously variable HIGH VOLTAGE from zero to maximum rated output voltage. Wide range of up to 100 kV is available in user selectable combinations.

  • AC Power Supplies

    BLC Series - Behlman Electronics Inc.

    The BLC Series delivers all the quality features our customers have come to expect from Behlman; clean sine wave output with excellent line and load regulation, high efficiency and low harmonic distortion. A multi-pulse input transformer offers low-input harmonic distortion and high power factor as required by European standards. Unique protection circuitry provides for over-temperature protection; short-circuit protection and voltage fold-back during overloads to maintain undistorted waveforms.

Get Help