Frequency Doublers
-
Product
Disciplined Frequency Standard
2975AR
-
The 2975AR contains a rubidium timebase and provide one 10 MHz, one 5 MHz and one Signal Generator output. The Signal Generator uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50 MHz using front panel controls or from an RS232 serial interface. The 2975AR can be disciplined by a 1pps input signal and provides a 1pps output signal. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
Product
4-Port 9 GHz Analyzer, Frequency Extension Compatible
C4409
-
C4409 Vector Network Analyzer delivers industry-leading dynamic range and sweep speed, with all the features engineers have come to expect included standard in our software. This VNA is frequency extender compatible and is the anchor network analyzer for the CobaltFx frequency extender system.
-
Product
AC Power Source, Frequency Converter
BL1350 Series
-
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
Product
Low Frequency 4-Way Power Dividers To 2200 MHz
-
Low Frequency 4-Way Power Dividers to 2200 MHz
-
Product
Frequency Down Converters
-
In digital signal processing, a digital down-converter (DDC) converts a digitized, band-limited signal to a lower frequency signal at a lower sampling rate in order to simplify the subsequent radio stages.
-
Product
4210A Rubidium Frequency Standard
-
Precise Time and Frequency, Inc.
The ptf 4210A Rubidium Frequency Standard is a unique solution for providing a highly stable, low phase noise, frequency reference for applications requiring atomic reference stability performance.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
Surface Mount Frequency Synthesizers
-
Corech Surface Mount Frequency Synthesizers series packs impressive low phase noise of -90dBc/Hz@1kHz, low spurious of -50dBc to -70dBc, high temperature and corrosion resistance, long operating life, temperature uniformity, and good thermal conductivity. These outstanding performance make it suitable for high-reliability and environmentally stressful applications including communication systems, test and measurement equipment, radar systems etc.
-
Product
Frequency and Phase Agile 120 MHz Signal Generator.
DDS8p
-
The DDS8p generates cosine, sine and ACMOS/TTL output signals. The frequency is programmable in 1µHz steps from 100Hz to 120MHz. The phase is 14-bit programmable. The DDS8p is controlled by a binary parallel interface that allows frequency and phase changes as fast as 600 nanoseconds. It is accurate to 1ppm and requires 5 VDC power.
-
Product
Frequency Large Display Indicator
-
Signals & Systems India Private Limited
Large Display indicator measures and displays frequency from the input like supply voltage, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Frequency. The large display is for clear visibility of the frequency reading from long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct frequency measurements of various devices.
-
Product
Audio Frequency System
Locator Set / UL 30
-
Cable fault location with the BAUR Locator Set / UL 30. The audio frequency system Locator Set is used to exactly determine the alignment of cables and metal gas or water pipes. With various accessories, this system becomes a universal, indispensable device for power companies, industries, installation companies and water suppliers.* Output energy up to 50 VA* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output
-
Product
High Frequency LCR Meters Up To 30MHz
Chroma 11050
-
Chroma Systems Solutions, Inc.
Measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components
-
Product
Integrated Frequency to Voltage Converter
FV
-
The FV6 Frequency to Voltage Module provides a convenient method of converting up to six frequency signals to analog voltages that can be fed into common data acquisition equipment.
-
Product
Voltage to Frequency Converters
-
Analog Devices has the widest range of voltage-to-frequency converters (VFCs) for the instrumentation, industrial, and automation markets. They are ideally suited for use in analog-to-digital conversion, long-term integration, linear frequency modulation and demodulation, and frequency-to-voltage conversion. ADI’s latest family of VFCs, the AD774x series, is based on Σ-Δ technology and provides high linearity in tiny packages at low cost.
-
Product
Frequency Generation
-
With expertise ranging from DDS down to VCO-based oscillators, CAES can provide for all of your frequency generation needs. Our extensive library of designs includes analog and digital solutions across a full range of frequencies and are well-suited for radar, missiles, electronic warfare, space and 5G communications applications.
-
Product
High Frequency LCR Meters up to 30MHz
11050
-
Chroma Systems Solutions, Inc.
The Chroma 11050 Series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range 75kHz~30MHz/1kHz~10 MHz/60Hz~5MHz suitable for analyzing component characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.
-
Product
Light-to-Frequency
-
Light-to-Frequency (LTF) sensors convert measurements of light intensity to a digital form for direct interfacing to a microcontroller. The output of the device is a square wave or pulse stream the frequency of which is linearly proportional to the light intensity. LTF converters are designed for applications such as ambient light measurement, light absorption/reflection in products such as white goods, photographic equipment, colorimetry, chemical analyzers and display contrast controls. They may be used in any system that requires a wide dynamic range, and/or high resolution digital measurement of light intensity.
-
Product
Frequency Converter
A6
-
The Quartzlock model A6 frequency converter precisely changes either 5 or 10MHz sine wave signals to a number of other frequencies from 1Hz and 1pps upwards to other standard frequencies.
-
Product
Ultra Low Noise, Rubidium Frequency Standard.
A10-M
-
Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.
-
Product
Economic Type Frequency Indicator
CS1-RL
-
CS1-F economic type Frequency Indicator has been designed with high accuracy measurement, display and communication of Frequency.The innovation feature is auto-range input from 0.01Hz~ 100KHz (option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of panels and testing applications.
-
Product
Dual Frequency 900 kHz & 2250 kHz 2D Imaging Sonar
BlueView M900-2250-S 130/45-Mk2
-
The dual frequency M900/2250-S 130/45-Mk2 is a new configuration of the leading BlueView M900/2250 optimized for superb image quality in challenging shallow water environments. The 900 kHz offers high-resolution long range navigation, object detection, and obstacle avoidance, while the 2250 kHz provides ultra-high resolution at close range. ROV navigation, diver hand held, hull inspections, structure inspections, diver monitoring, and search and recovery are a few applications that benefit from the dual-frequency’s imaging capabilities. All M Series sonar operate while in motion or from a stationary position delivering real-time imagery and data.
-
Product
Low Frequency 2-Way Power Dividers To 3000 MHz
-
Power dividers from 4 kHz to 3 GHz are available from Pulsar Microwave in connectorized packages with SMA-female connectors, standard. This series is designed to handle 1 watt input power. They are designed for use in 50-ohm systems, and cover frequencies for VHF, UHF, Cell and PCS applications.
-
Product
Radio Frequency (RF) Recording and Playback Instruments
-
Adivic Radio Frequency (RF) Recording and Playback Instruments
-
Product
Frequency Converter up UHF AXIe-0 Up
AXIe-0 Up UHF Module
-
The AXIe-0 Up LMHF module is a carrier of mezzanine modules made in the AXIe-0 standard. The module ensures the functioning of various modules installed in it, made in the form of double mezzanines. The number of slots in the module is one.
-
Product
Frequency Response Analyser
DP-cPCI-7554
-
DP-cPCI-7554 is a cPCI module capable of analyzing the phase and gain characteristics of a system. The system under test is stimulated by the user defined waveform. The obtained response is correlated with the applied stimulus by the on-board DSP processor to determine the phase difference and the gain.Gain and the face analysis is carried out only at sine waveform.
-
Product
Frequency Doubling Comb Generator
COMBGEN6DIFF
-
*Differential output - can also provide two separate single ended complementary outputs.*Pulse height of up to +4V peak into 50 ohms, on positive output*Pulse height of up to -4V peak into 50 ohms, on negative output*Rise time < 80pS, FWHM of approximately 120pS*Produces pulse on both edges of input clock, thereby doubling frequency.*Input clock may be sinewave from 50MHz to 2GHz or square wave from 5MHz to 2GHz, producing fundamental comb tooth energy from 10MHz to 4GHz.*Usable energy to >10GHz.*Can drive any load, including short, without damage.*Power Requirements: -12V @ 120mA and +24V @ 80mA
-
Product
Static Frequency Converter Systems
-
Our software and connectivity devices incorporate all the features you need to proactively manage your systems, from basic monitoring and shutdown to predictive analysis and power management. Aplab Integration Services offer complete solutions tailored for the specific requirements of Defense Services, Telecom and Commercial markets.
-
Product
RF Frequency Divider, Multiplier, & Detector Modules
-
Analog Devices’ broad portfolio of frequency dividers, multipliers, and detector modules offers a number of high performance solutions, with features such as ultralow phase noise and improved frequency lock time to meet the demands of modern technology. Explore our product lines and discover how they can meet your industry, market, and design needs.
-
Product
High Frequency Standard Capacitor
GenRad 1403 Series
-
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.